Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering

Journal Search

  1. Home
  2. Archive
  3. 2016-08 (Vol.28 No.08)
  4. 10.6110/KJACR.2016288.316

Journal XML


References

1
Lee J. H., Lee D. Y., 2013, Experimental study of a counter flow regenerative evaporative cooler with finned channels, Int. Journal of Heat and Mass Transfer, Vol. 65, pp. 173-179DOI
2
Duan Z., Zhan C., Zhang X., Mustafa M., Zhao X., Alimohammadisagvand B., Hasan A., 2012, Indirect evaporative cooling : Past, present and future potentials, Renewable Sustainable Energy Reviews, Vol. 16, No. 9, pp. 6823-6850DOI
3
Maisotsenko V. S., Zimmerman A. B., Mikhaylova L. D., Pechorskaya I. M., 1977, Method of indirect- evaporative air cooling in household electrical appliances, Proceedings of World Electrotechnical Congress, Moscow, USSR.Google Search
4
Riangvilaikul B., Kumar S., 2010, An experimental study of a novel dew point evaporative cooling system, Energy and Buildings, Vol. 42, No. 5, pp. 637-644DOI
5
Riangvilaikul B., Kumar S., 2010, Numerical study of a novel dew point evaporative cooling system, nergy and Buildings, Vol. 42, No. 11, pp. 2241-2250DOI
6
Hasan A., 2010, Indirect evaporative cooling of air to a sub-wet bulb temperature, Applied Thermal Engineering, Vol. 30, No. 16, pp. 2460-2468DOI
7
Bruno F., 2011, On-site experimental testing of a novel dew point evaporative cooler, Energy and Buildings, Vol. 43, No. 12, pp. 3475-3483DOI
8
Zhan C., Duan Z., Zhao X., Smith S., Jin H., Riffat S., 2011, Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative coolingPaving the path toward sustainable cooling of buildings, Energy, Vol. 36, No. 12, pp. 6790-6805DOI
9
Kozubal E., Woods J., Judkoff R., 2012, Development and Analysis of Desiccant Enhanced Evaporative Air Conditioner Prototype, National Renewable Energy Laboratory, Vol. TP-5500-54755.Google Search
10
Woods J., Kozubal E., 2013, A desiccant- enhanced evaporative air conditioner : Numerical model and experiments, Energ Convers Manage, Vol. 65, pp. 208-220DOI
11
Cui X., Chua K. J., Yang W. M., Ng K. C., Thu K., Nguyen V. T., 2014, Studying the performance of an improved dew-point evaporative design for cooling application, Applied Thermal Engineering, Vol. 63, No. 2, pp. 624-633DOI
12
Anisimov S., Pandelidis D., Jedlikowski A., Polushkin V., 2014, Performance investigation of a M(Maisotsenko) -cycle cross-flow heat exchanger used for indirect evaporative cooling, Energy, Vol. 76, pp. 593-606DOI
13
Moshari S., Heidarinejad G., 2015, Numerical study of regenerative evaporative coolers for sub-wet bulb cooling with cross- and counter-flow configuration, Applied Thermal Enginerring, Vol. 89, pp. 669-683DOI
14
Lee J. H., Choi B. S., Lee D. Y., 2013, Comparison of configurations for a compact regenerative evaporative cooler, Int. Journal of Heat and Mass Transfer, Vol. 65, pp. 192-198DOI
15
Duan Z., Zhan C., Zhao X., Dong X., 2016, Experimental study of a counter-flow regenerative evaporative cooler, Building and Environment, Vol. 104, pp. 47-58DOI
16
Lee D. Y., Lee J. W., Kang B. H., 2005, An experimental study on the effects of porous layer treatment on evaporative cooling of an inclined surface, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 1, pp. 25-32Google Search
17
Wang T. A., Reid R. L., 1996, Surface wettability effect on an indirect evaporative cooling system, ASHRAE Transactions, Vol. 102, No. 1, pp. 427-433Google Search