Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering

Journal Search

  1. Home
  2. Archive
  3. 2017-07 (Vol.29 No.07)
  4. 10.6110/KJACR.2017297.373

Journal XML


References

1
Yoon J. S., Kwon O. K., Cha D. A., Bae K. J., Kim I. G., Kim M. S., Park C. W., 2016, Effects of Operation condition on the performance of Type II LiBr-H2O absorption Heat Pump, Proceeding of SAREK, pp. 149-151Google Search
2
Kang B. H., Kim Y. I., Lee C. S., 1985, Thermal Design Analysis of an Absorption Heat Transformer for using Waste Hot Water, The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 14, No. 4, pp. 11-18Google Search
3
Chen J., 1995, Optimal choice of the performance parameters of an absorption heat transformer, Heat Recovery Syst. CHP, Vol. 15, No. 3, pp. 249-256DOI
4
Chen J., 1997, Equivalent combined cycle of an endoreversible absorption heat transformer and optimal analysis of primary performance parameters, Energy Convers. Mgmt., Vol. 38, No. 7, pp. 705-712DOI
5
Chen J., 1997, Thermodynamic analysis of the performance of a solar absorption heat transformer at maximum coefficient of performance, Int. J. Energy Res., Vol. 21, pp. 975-984DOI
6
Qin X. Y., Chen L. G., Sun F. R., 2004, The optimal performance of an irreversible four-heat-reservoir absorption heat transformer, J. Eng. Thermophys., S. Wu, J. Chen, Vol. 25, pp. 185-188Google Search
7
Wu S. Z., Chen J. C., 2005, Parametric optimum design of an irreversible heat-transformer based on the thermo-economic approach, Appl. Energy, Vol. 80, pp. 349-365DOI
8
Qin X., Chen L., Sun F., Wu C., 2005, Performance of an endoreversible four-heat-reservoir absorption heat-transformer with a generalized heat transfer law, Int. J. Ambient Energy, Vol. 26, pp. 171-179DOI
9
Sun F., Qin X., Chen L., Wu C., 2005, Optimization between heating load and entropy-production rate for endoreversible absorption heat-transformers, Appl. Energy, Vol. 81, pp. 434-448DOI
10
Eisa M. A. R., Best R., Holland R. F. A., 1986, Thermodynamic design data for absorption heat transformers-part I. Operating water-lithium bromide, J. Heat Recovery Syst., Vol. 6, No. 5, pp. 421-432DOI
11
Wang J. G., Ma X. H., Lin H. T., Chen J. B., 2004, Thermodynamic analysis for LiBr-H2O absorption heat transformer, J. Dalian Univ. Technol., Vol. 44, pp. 366-370Google Search
12
Zebbar D., Kherris S., Zebbar S., Mostefa K., 2012, Thermodynamic optimization of an absorption heat transformer, Int. J. Refrig., Vol. 35, pp. 1393-1401DOI
13
Guo P., Sui J., Han W., Zheng J., Jin H., 2012, Energy and exergy analyses on the off-design performance of an absorption heat transformer, Appl. Therm. Eng., Vol. 48, pp. 506-514DOI

AltStyle によって変換されたページ (->オリジナル) /