Notifications
You must be signed in to change notification settings - Fork 7
Technical Data Clamp Multimeter (1)
ludwich66 edited this page Aug 12, 2022
·
8 revisions
Display (3)
Function
Range
Accuracy
DC Voltage
6V/60V/600V
±(0.5%+3)
AC Voltage
6V/60V/600V
±(1%+3)
DC Current
600uA/6000uA/60mA/600mA/6A/10A
±(1.0%+3)
AC Current
6A
±(5%+30)
AC Current
60A/600A
±(2.5%+30)
Resistance
6kΩ
±(1.5%+3)
Resistance
60kΩ/600kΩ/6MΩ/60MΩ
±(0.5%+3)
Capacitance
9.999nF
±(5.0%+2)
Capacitance
99.99nF
±(2.0%+5)
Capacitance
999.9nF
±(2.0%+5)
Capacitance
9.999uF
±(2.0%+5)
Capacitance
99.99uF
±(2.0%+5)
Capacitance
999.9uF
±(2.0%+5)
Capacitance
9.999mF max.4mF
±(5.0%+5)
Frequency
9.999Hz
±(0.1%+2)
Frequency
99.99Hz
±(0.1%+2)
Frequency
999.9Hz
±(0.1%+2)
Frequency
9.999kHz
±(0.1%+2)
Frequency
99.99kHz
±(0.1%+2)
Frequency
999.9kHz
±(0.1%+2)
Frequency
9.999MHz
±(0.1%+2)
Duty Cycle
1%~99% Res. 0,1%
±(0.1%+2)
Temp intern
(-30°C – 1000°C) Res. 1°C
±(2.5%+5)
Temp extern
Cr/Ni Sensor
DiodeTest
yes LED all Colors
Continuity
yes
InrushCurrent
yes
Peek Hold
yes
Min Funktion
yes
Max Funktion
yes
Rel Funktion
yes
NCV Test:
yes PowerCordSearcher
Bluetooth:
yes
Counts:
6000
Power:
2 AA Mignon
Low Bat Ind.
yes
TimeOut:
15 Min // OFF
Update Rate:
1/3 Second
TrueRMS:
yes
??| Fuse | 20mm Ceramic 10A | |
??| Fuse | 20mm Ceramic 600mA | |