Jump to content
Wikipedia The Free Encyclopedia

Talk:Aberration-corrected transmission electron microscopy

Page contents not supported in other languages.
Add topic
From Wikipedia, the free encyclopedia
Latest comment: 1 year ago by 81.89.202.227 in topic TEAM 0.5 facility
This is the talk page for discussing improvements to the Aberration-corrected transmission electron microscopy article.
This is not a forum for general discussion of the subject of the article.
Find sources:Google (books · news · scholar · free images · WPrefs) · FENS · JSTOR · TWL
This article is rated C-class on Wikipedia's content assessment scale.
It is of interest to the following WikiProjects:
WikiProject icon Microbiology Mid‐importance
WikiProject icon This article is within the scope of WikiProject Microbiology , a collaborative effort to improve the coverage of Microbiology on Wikipedia. If you would like to participate, please visit the project page, where you can join the discussion and see a list of open tasks.MicrobiologyWikipedia:WikiProject MicrobiologyTemplate:WikiProject MicrobiologyMicrobiology
Mid This article has been rated as Mid-importance on the project's importance scale.
WikiProject icon This article is within the scope of WikiProject Molecular Biology , a collaborative effort to improve the coverage of molecular biology on Wikipedia. If you would like to participate, please visit the project page, where you can join the discussion and see a list of open tasks.Molecular BiologyWikipedia:WikiProject Molecular BiologyTemplate:WikiProject Molecular BiologyMolecular Biology
??? This article has not yet received a rating on the project's importance scale.
Taskforce icon
This article is supported by the Molecular and Cell Biology task force (assessed as Mid-importance).
WikiProject icon Physics Mid‐importance
WikiProject icon This article is within the scope of WikiProject Physics , a collaborative effort to improve the coverage of Physics on Wikipedia. If you would like to participate, please visit the project page, where you can join the discussion and see a list of open tasks.PhysicsWikipedia:WikiProject PhysicsTemplate:WikiProject Physicsphysics
Mid This article has been rated as Mid-importance on the project's importance scale.

TEAM 0.5 facility

[edit ]
Latest comment: 1 year ago 3 comments3 people in discussion

@Ldm1954, as far as I know, TEAM 0.5 has only ever been at NCEM at LBNL. The old website also seems to confirm that. Is there some source saying that TEAM 0.5 was originally housed at ANL? Niashervin (talk) 16:36, 1 September 2024 (UTC) Reply

I thought the ACAT at ANL was called TEAM 0.5, but I guess it is a different instrument. The ACAT was perhaps even earlier than 0.5/ Ldm1954 (talk) 16:44, 1 September 2024 (UTC) Reply
The ACAT at the ANL was a part of the TEAM project to explore the chromatic aberration correction on the conventional TEM side of the final instrument. Another part of the TEAM project was the prototype DCOR and prototype X-FEG for STEM at the ORNL. The TEAM 0.5 at NCEM does not have chromatic aberration correction but a monochromator. 81.89.202.227 (talk) 11:29, 12 December 2024 (UTC) Reply

AltStyle によって変換されたページ (->オリジナル) /