faqs.org - Internet FAQ Archives

RFC 3591 - Definitions of Managed Objects for the Optical Interf


Or Display the document by number



Network Working Group H-K. Lam
Request for Comments: 3591 Lucent Technologies
Category: Standards Track M. Stewart
 Dorado Software
 A. Huynh
 Cetus Networks
 September 2003
 Definitions of Managed Objects for the Optical Interface Type
Status of this Memo
 This document specifies an Internet standards track protocol for the
 Internet community, and requests discussion and suggestions for
 improvements. Please refer to the current edition of the "Internet
 Official Protocol Standards" (STD 1) for the standardization state
 and status of this protocol. Distribution of this memo is unlimited.
Copyright Notice
 Copyright (C) The Internet Society (2003). All Rights Reserved.
Abstract
 This memo defines a portion of the Management Information Base (MIB)
 for use with Simple Network Management Protocol (SNMP) in TCP/IP-
 based internets. In particular, it defines objects for managing
 Optical Interfaces associated with WavelengthDivision Multiplexing
 systems or characterized by the Optical Transport Network (OTN) in
 accordance with the OTN architecture defined in ITU-T Recommendation
 G.872.
 The MIB module defined in this memo can be used for performance
 monitoring and/or configuration of such optical interface.
Table of Contents
 1. The Internet-Standard Management Framework ................. 2
 2. Overview ................................................... 3
 2.1. Use of the ifTable .................................. 3
 2.2. Use of ifTable for OTN OTS/OMS Layer................. 8
 2.3. Use of ifTable for OTN OChGroup Layer................ 9
 2.4. Use of ifTable for OTN OCh Layer..................... 10
 2.5. Use of ifStackTable.................................. 12
 2.6. Optical Network Terminology ......................... 13
 2.7. Tandem Connection Monitoring (TCM) .................. 20
 3. Structure of the MIB........................................ 21
 3.1. The optIfOTMn group.................................. 23
 3.2. The optIfPerfMon group............................... 24
 3.3. The optIfOTSn groups................................. 24
 3.4. The optIfOMSn groups................................. 25
 3.5. The optIfOChGroup groups............................. 26
 3.6. The optIfOCh groups.................................. 27
 3.7. The optIfOTUk groups................................. 28
 3.8. The optIfODUk groups................................. 29
 3.9. The optIfODUkT groups................................ 30
 4. Object Definitions ......................................... 30
 5. Security Considerations .................................... 167
 6. Acknowledgments............................................. 169
 7. References ................................................. 169
 7.1. Normative References ................................. 169
 7.2. Informative References ............................... 171
 8. Intellectual Property Statement ............................ 171
 9. Authors' Addresses ......................................... 172
 10. Full Copyright Statement ................................... 173
1. The Internet-Standard Management Framework
 For a detailed overview of the documents that describe the current
 Internet-Standard Management Framework, please refer to section 7 of
 RFC 3410 [RFC3410].
 Managed objects are accessed via a virtual information store, termed
 the Management Information Base or MIB. MIB objects are generally
 accessed through the Simple Network Management Protocol (SNMP).
 Objects in the MIB are defined using the mechanisms defined in the
 Structure of Management Information (SMI). This memo specifies a MIB
 module that is compliant to the SMIv2, which is described in STD 58,
 RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
 [RFC2580].
2. Overview
 In this document, the term OTN (Optical Transport Network) system is
 used to describe devices that are compliant with the requirements
 specified in the ITU-T Recommendations G.872 [ITU-T G.872], G.709
 [ITU-T G.709], G.798 [ITU-T G.798], G.874 [ITU-T G.874], and G.874.1
 [ITU-T G.874.1].
 The optical objects will be managed using the MIB II ifTable and
 ifStackTable. Additional tables will also be supported to monitor
 layer specific status and provide performance monitoring data. In
 the tables, some entries are required for OTN systems only. A
 Configuration (Config) table, Current Performance Monitoring (PM)
 table, and Interval PM table will be maintained for the OTSn, OMSn,
 OChGroup, and OCh layers on a source and sink trail termination
 basis. These tables will be linked to the ifTable by using the
 ifIndex that is associated with that layer.
 These objects are used when the particular media being used to
 realize an interface is an Optical Transport interface. At present,
 this applies to these values of the ifType variable in the Internet-
 standard MIB:
 opticalChannel (195), opticalChannelGroup (219), opticalTransport
 (196)
 The definitions contained herein are based on the OTN specifications
 in ITU-T G.872[ITU-T G.872], G.709 [ITU-T G.709], G.798[ITU-T G.798],
 G.874[ITU-T G.874], and G.874.1 [ITU-T G.874.1].
2.1. Use of the ifTable
 This section specifies how the MIB II interfaces group, as defined in
 RFC 2863 [RFC2863], is used for optical interfaces. Only the
 ifGeneralInformationGroup will be supported for the ifTable and the
 ifStackTable to maintain the relationship between the various layers.
 The OTN layers are managed in the ifTable using IfEntries that
 correlate to the layers depicted in Figure 1.
 For example, a DWDM device with an Optical Network Node Interface
 (ONNI) will have an Optical Transmission Section (OTS) physical
 layer, an Optical Multiplex Section (OMS) layer (transports multiple
 optical channels), and an Optical Channel (OCh) layer. There is a
 one to one relationship between the OMS and OTS layers. The OMS
 layer has fixed connectivity via the OTS and thus no connectivity
 flexibility at the OMS layer is supported.
 A device with an ONNI that does not multiplex would consist of the
 OTS and OCh layers supporting a single channel.
 MIB-II (RFC 1213) [RFC1213], as amended and extended by RFC 3418
 [RFC3418], RFC 2863 [RFC2863], and RFC 2864 [RFC2864], accommodates
 these cases through appropriate use of the system and interfaces
 groups. The system group names and describes the type of managed
 resource. The interfaces group defines which OTN layers exist and
 how these layers are configured and multiplexed. This is achieved by
 proper representation of OTN Layers as IfEntries as defined in RFC
 2863 [RFC2863], as follows.
 In the following figures, opticalChannel and opticalTransport are
 abbreviated as och and otn respectively.
 _____________________
 \
 Path Data Unit |\
 (ODUk) | \
 _____________________| \ ______________________
 | | | >
 Tandem Data Unit | | | |
 (ODUkT) | | OCh Layer | > n och IfEntries
 _____________________| | | |
 | |______________________| >
 Optical | /| | >
 Transport Unit | / | | |
 (OTUk) |/ | OMSn Layer | |
 _____________________/ | | |
 |______________________| |
 Sub-layers in | | > m otn IfEntries
 the OCh Layer | | |
 | OTSn Layer | |
 | | |
 |______________________| >
 Figure 1: OTN Layers
 Since the OMSn and OTSn layers have a one to one relationship, only
 one otn IfEntry is required to support these two layers. Therefore,
 each opticalChannel IfEntry may be mapped to m opticalTransport
 IfEntries, where m is greater than or equal to 1. Conversely, each
 opticalTransport entry may be mapped to n opticalChannel IfEntries,
 where n is greater than or equal to 1.
 There are implementations that have banded amplifers that operate on
 a group of optical channels separately (e.g., C and L band channels)
 before finally muxing them together and transporting them over a
 physical layer. For such DWDM system implementations, it is
 important to have the ability to model each of the groups (or bands)
 with an ifIndex and measure the pre-OTN PM parameters for each band
 separately.
 The OTN layering, as described in Figure 1, can be extended to
 accomodate such implementations by introducing another layer called
 the OChGroup Layer.
 As an example, Figure 2 depicts the OTN layering of a DWDM system
 with 80 C-band and 80 L-band channels combined into their respective
 channel band groups before being muxed into the OMS and transported
 over the OTS.
 _________ ____________
 |O|O| |O | |O |O | |O | >
 |C|C| |C | |C |C | |C | |
 |h|h|..|h | |h |h |..|h | > x och IfEntries
 |1|2| |80| |81|82| |160| |
 |_|_|__|__| |__|__|__|___| >
 | | | | >
 | | | | |
 |OChGroup1| | OChGroup2 | > n ochgroup IfEntries
 | | | | |
 |_________|__|____________| >
 | | >
 | | |
 | OMSn Layer | |
 | | |
 |_________________________| |
 | | > m otn IfEntries
 | | |
 | OTSn Layer | |
 | | |
 |_________________________| >
 Figure 2: OTN Layers for a Banded Configuration
 If an implementation does not wish to model the banded configuration,
 the OChGroup layer is absent and the OTN layering model degenerates
 to the description in Figure 1. In other words, when there is an
 amplifier that covers the whole band, the optIfOMSn objects should be
 used, rather than using the optIfOChGroup objects with a degenerate
 group that covers all channels.
 The design of the Optical Interface MIB provides the option to model
 an interface either as a single bidirectional object containing both
 sink and source functions or as a pair of unidirectional objects, one
 containing sink functions and the other containing source functions.
 If the sink and source for a given protocol layer are to be modelled
 as separate objects, then there need to be two ifTable entries, one
 that corresponds to the sink and one that corresponds to the source,
 where the directionality information is provided in the configuration
 tables for that layer via the xxxDirectionality objects. The agent
 is expected to maintain consistent directionality values between
 ifStackTable layers (e.g., a sink must not be stacked in a 1:1 manner
 on top of a source, or vice-versa), and all protocol layers that are
 represented by a given ifTable entry are expected to have the same
 directionality (i.e., instances of optIfOTSnDirectionality and
 optIfOMSnDirectionality that correspond to a given ifIndex value must
 have the same value, and instances of optIfOChDirectionality,
 optIfOTUkDirectionality, and optIfODUkDirectionality that correspond
 to a given ifIndex value must have the same value).
 When separate ifTable entries are used for the source and sink
 functions of a given physical interface, association between the two
 uni-directional ifTable entries (one for the source function and the
 other for the sink functions) should be provided. It is recommended
 that identical ifName values are used for the two ifTable entries to
 indicate such association. An implementation shall explicitly state
 what mechanism is used to indicate the association, if ifName is not
 used.
 Example 1: Management of unterminated opticalChannel (och) using
 passive optics
 An OTN device connected with two adjacent nodes in a single fiber
 ring that supports 10 wavelengths per fiber would have 2
 opticalTransport IfEntries and 20 opticalChannel IfEntries, as
 depicted in Figure 3. Thus 10 opticalChannel IfEntries are
 stacked above the first opticalTransport IfEntry, and the other 10
 opticalChannel IfEntries are stacked above the second
 opticalTransport IfEntry. Note that the optical channels in this
 example are un-terminated, and thus no OTUk objects will be
 instantiated for these optical channels. The opticalChannel
 IfEntries of one otn may be dropped/added from/to the OTN device
 or cross-connected with the opticalChannel IfEntries of the other
 otn. Cross-connection from a member of the first 10
 opticalChannel IfEntries to a member of the second 10
 opticalChannel IfEntries could be modelled by using a cross-
 connect object, which is not yet defined in this version of the
 MIB.
 ______________________ ______________________
 | | | | | | | |
 | och1 | ... | och10 | | och11 | ... | och20 |
 |_______|______|_______| |_______|______|_______|
 | | | |
 | otn1 | | otn2 |
 |______________________| |______________________|
 ____________
 | |
 ___________________\| OTN |__________________\
 /| device | /
 |____________|
 Figure 3: Interface stacks when channels are unterminated
 Example 2: Management of terminated opticalChannel (och) interfaces
 An OTN device connected with two adjacent nodes in a single fiber
 ring that supports 10 wavelengths per fiber would have 2
 opticalTransport IfEntries and 20 opticalChannel IfEntries, as
 depicted in Figure 4. Thus 10 opticalChannel IfEntries are
 stacked above the first opticalTransport IfEntry, and the other 10
 opticalChannel IfEntries are stacked above the second
 opticalTransport IfEntry. As the optical channels in this example
 are terminated, OTUk objects and possibly ODUk objects will be
 instantiated for the terminated opticalChannel IfEntries.
 ______________________ ______________________
 | | | | | | | |
 | och1 | ... | och10 | | och11 | ... | och20 |
 |_______|______|_______| |_______|______|_______|
 | | | |
 | otn1 | | otn2 |
 |______________________| |______________________|
 ____________
 | |
 ___________________\| OTN |__________________\
 /| device | /
 |____________|
 Figure 4: Interface stacks when channels are terminated
 Note that the two examples described above depict the interface
 stacks when the banded configuration is not modeled.
 The exact configuration and multiplexing of the layers is maintained
 in the ifStackTable (RFC 2863) [RFC2863] and in the ifInvStackTable
 (RFC 2864) [RFC2864]; see section 2.5 for details.
2.2. Use of ifTable for OTN OTS/OMS Layer
 Only the ifGeneralInformationGroup needs to be supported.
 ifTable Object Use for combined OTN OTS/OMS Layer
 =====================================================================
 ifIndex The interface index.
 ifDescr Optical Transport Network (OTN) Optical
 Transmission Section (OTS)/Optical Multiplex
 Section (OMS)
 ifType opticalTransport (196)
 ifSpeed Actual bandwidth of the interface in bits per
 second. If the bandwidth of the interface is
 greater than the maximum value of 4,294,967,295,
 then the maximum value is reported and
 ifHighSpeed must be used to report the
 interface's speed.
 ifPhysAddress An octet string with zero length. (There is
 no specific address associated with the
 interface.)
 ifAdminStatus The desired administrative status of the
 interface. Supports read-only access.
 ifOperStatus The operational status of the interface. The
 value lowerLayerDown(7) is not used, since
 there is no lower layer interface. This object
 is set to notPresent(6) if a component is
 missing, otherwise it is set to down(2) if
 either of the objects optIfOTSnCurrentStatus or
 optIfOMSnCurrentStatus indicates that any
 defect is present.
 ifLastChange The value of sysUpTime at the last change in
 ifOperStatus.
 ifName Enterprise-specific convention (e.g., TL-1 AID)
 to identify the physical or data entity
 associated with this interface or an
 OCTET STRING of zero length. The
 enterprise-specific convention is intended to
 provide the means to reference one or more
 enterprise-specific tables.
 ifLinkUpDownTrapEnable Default value is enabled(1). Supports
 read-only access.
 ifHighSpeed Actual bandwidth of the interface in Mega-bits
 per second. A value of n represents a range of
 'n-0.5' to 'n+0.499999'.
 ifConnectorPresent Set to true(1).
 ifAlias The (non-volatile) alias name for this interface
 as assigned by the network manager.
2.3. Use of ifTable for OTN OChGroup Layer
 Only the ifGeneralInformationGroup needs to be supported.
 ifTable Object Use for OTN OChGroup Layer
 =====================================================================
 ifIndex The interface index.
 ifDescr Optical Transport Network (OTN) Optical
 Channel Group (OChGroup)
 ifType opticalChannelGroup(219)
 ifSpeed Current bandwidth of the interface in bits per
 second. If the bandwidth of the interface is
 greater than the maximum value of 4,294,967,295,
 then the maximum value is reported and
 ifHighSpeed must be used to report the
 interface's speed.
 ifPhysAddress A string that specifies the range of wavelengths
 in the format of w1-w2, where w1 and w2 are the
 lower and upper end of the wavelength range,
 both in ASCII decimal digits expressed in
 nanometers (e.g., 1350-1650)
 ifAdminStatus The desired administrative status of the
 interface. Supports read-only access.
 ifOperStatus The operational status of the interface. This
 object is set to lowerLayerDown(7) if the
 ifOperStatus of its otn interface is down(2).
 Otherwise, it is set to down(2) if the
 amplifier for this band is unable to carry
 traffic.
 ifLastChange The value of sysUpTime at the last change in
 ifOperStatus.
 ifName Enterprise-specific convention (e.g., TL-1 AID)
 to identify the physical or data entity
 associated with this interface or an
 OCTET STRING of zero length. The
 enterprise-specific convention is
 intended to provide the means to reference one
 or more enterprise-specific tables.
 ifLinkUpDownTrapEnable Default value is disabled(2). Supports
 read-only access.
 ifHighSpeed Current bandwidth of the interface in Mega-bits
 per second. A value of n represents a range of
 'n-0.5' to 'n+0.499999'.
 ifConnectorPresent Set to false(2).
 ifAlias The (non-volatile) alias name for this interface
 as assigned by the network manager.
2.4. Use of ifTable for OTN OCh Layer
 Only the ifGeneralInformationGroup needs to be supported.
 ifTable Object Use for OTN OCh Layer
 =====================================================================
 ifIndex The interface index.
 ifDescr Optical Transport Network (OTN) Optical
 Channel (OCh)
 ifType opticalChannel(195)
 ifSpeed Current bandwidth of the interface in bits per
 second. If the bandwidth of the interface is
 greater than the maximum value of 4,294,967,295,
 then the maximum value is reported and
 ifHighSpeed must be used to report the
 interface's speed.
 ifPhysAddress A string of ASCII decimal digits containing the
 wavelength of the optical channel, expressed
 in nanometers (e.g., 1550).
 ifAdminStatus The desired administrative status of the
 interface. Supports read-only access.
 ifOperStatus The operational status of the interface. This
 object is set to lowerLayerDown(7) if the
 ifOperStatus of its otn interface or of its
 OChGroup interface is down(2).
 Otherwise, it is set to down(2) if one or more
 of the objects optIfOChCurrentStatus,
 optIfOTUkCurrentStatus, optIfODUkTCurrentStatus,
 and optIfODUkTtpCurrentStatus indicates
 that any defect is present.
 ifLastChange The value of sysUpTime at the last change in
 ifOperStatus.
 ifName Enterprise-specific convention (e.g., TL-1 AID)
 to identify the physical or data entity
 associated with this interface or an
 OCTET STRING of zero length. The
 enterprise-specific convention is
 intended to provide the means to reference one
 or more enterprise-specific tables.
 ifLinkUpDownTrapEnable Default value is disabled(2). Supports
 read-only access.
 ifHighSpeed Current bandwidth of the interface in Mega-bits
 per second. A value of n represents a range of
 'n-0.5' to 'n+0.499999'.
 ifConnectorPresent Set to false(2).
 ifAlias The (non-volatile) alias name for this interface
 as assigned by the network manager.
2.5. Use of ifStackTable
 Use of the ifStackTable and ifInvStackTable to associate the
 opticalTransport and opticalChannel interface entries is best
 illustrated by the example shown in Figure 5. The example assumes an
 otn interface with ifIndex i that carries two multiplexed och
 interfaces with ifIndex values of j and k, respectively. The example
 shows that j and k are stacked above (i.e., multiplexed into) i.
 Furthermore, it shows that there is no layer lower than i and no
 layer higher than j and/or k.
 HigherLayer LowerLayer
 --------------------------
 0 j
 0 k
 j i
 k i
 i 0
 Figure 5: Use of ifStackTable for an OTN port
 Figure 6 illustrates an example for a banded configuration. The
 example assumes an otn interface with ifIndex i that carries two
 multiplexed och groups with ifIndex values u and v. An och group
 with ifIndex value u combines two och interfaces with ifIndex values
 of a and b. An och group with ifIndex value v combines two och
 interfaces with ifIndex values of c and d. The example show that a
 and b are stacked above (i.e., multiplexed into) u. Likewise, c and
 d are stacked above v. u and v are multiplexed into i. Furthermore,
 it shows that there is no layer lower than i and no layer higher than
 a, b, c, and/or d. It also shows that u has a and b as its higher
 layers, and v has c and d as its higher layers.
 HigherLayer LowerLayer
 --------------------------
 0 a
 0 b
 0 c
 0 d
 a u
 b u
 c v
 d v
 u i
 v i
 i 0
Figure 6: Use of ifStackTable for an OTN port for a banded configuration
 For the inverse stack table, it provides the same information as the
 interface stack table, with the order of the Higher and Lower layer
 interfaces reversed.
2.6. Optical Network Terminology
 The terminology used in this document to describe the layers of an
 optical network and the error conditions and performance monitoring
 parameters on an optical circuit as monitored by an optical system is
 listed below. These terms are defined in ITU-T Recommendations G.872
 [ITU-T G.872], G.709 [ITU-T G.709], G.798 [ITU-T G.798], G.874 [ITU-T
 G.874], G.874.1 [ITU-T G.874.1], and G.806 [ITU-T G.806]. Brief
 definitions of some terms are also included here to facilitate the
 readability of this document.
 Degraded Threshold (DEGTHR) - G.806
 A threshold level for declaring a performance monitoring (PM)
 Second (a time period of one second) to be bad. A PM Second is
 declared bad if the percentage of detected errored blocks in
 that second or the number of errored blocks in that Second is
 greater than or equal to DEGTHR.
 DEGM - G.806
 A threshold level for declaring a Degraded Signal defect
 (dDEG). A dDEG shall be declared if DEGM consecutive bad PM
 Seconds are detected.
 Expected Destination Access Point Identifier (ExDAPI) - G.798
 The Expected Destination Access Point Identifier (ExDAPI),
 provisioned by the managing system, to be compared with the TTI
 accepted at the overhead position of the sink for the purpose
 of checking the integrity of connectivity.
 Expected Source Access Point Identifier (ExSAPI) - G.798
 The Expected Source Access Point Identifier (ExSAPI),
 provisioned by the managing system, to be compared with the TTI
 accepted at the overhead position of the sink for the purpose
 of checking the integrity of connectivity.
 Inter-Domain Interface (IrDI) - G.872
 A physical interface that represents the boundary between two
 administrative domains.
 G.709 defines the requirements for the IrDI at the Network Node
 Interface (NNI).
 Intra-Domain Interface (IaDI) - G.872
 A physical interface within an administrative domain.
 Optical Channel Layer Network (OCh) - G.872
 This layer network provides end-to-end networking of optical
 channels for transparently conveying client information of
 varying format (e.g., SDH STM-N, PDH 565 Mbit/s, cell based
 ATM, etc.).
 Optical Channel Data Unit Path Layer Network (ODUk) - G.709/Y.1331
 This layer network provides functionality for the transport of
 information structure consisting of the information payload
 (OPUk) and the related overhead for management of an optical
 channel.
 Optical Channel Data Unit Tandem Connection Sub-Layer Network (ODUkT)
 - G.709/Y.1331
 This layer network is a sub-layer of the optical data unit
 layer, which provides the capability for tandem connection
 monitoring. One to six nested levels of monitoring are defined
 for OTN.
 Optical Channel Payload Unit (OPUk) - G.709/Y.1331
 The OPUk is the information structure used to adapt client
 information for transport over an optical channel. OPUk
 capacities for k=1, k=2, k=3 are defined in ITU-T. The index
 "k" is used to represent different versions of OPUk, ODUk and
 OTUk. k=1 represents an approximate bit rate of 2.5 Gbit/s,
 k=2 represents an approximate bit rate of 10 Gbit/s, and k=3
 represents an approximate bit rate of 40 Gbit/s.
 Optical Multiplex Section Layer Network (OMS) - G.872
 This layer network provides functionality for networking of a
 multi-wavelength optical signal. Note that a "multi-
 wavelength" signal includes the case of just one optical
 channel.
 Optical Transport Module (OTM-n[r].m) - G.872
 The OTM is the information structure that is transported across
 an ONNI. The index n and m define the number of supported
 wavelengths and bit rates at the interface.
 Two OTM structures are defined: OTM with full functionality
 (OTM-n.m) and OTM with reduced functionality (OTM-0.m & OTM-
 nr.m).
 The OTM-n.m consists of up to n multiplexed optical channels
 and an OTM overhead signal to support the non-associated
 overhead. The OTM-0 consists of a single optical channel
 without a specific color assigned. The OTM-nr.m consists of up
 to n multiplexed optical channels. Non associated overhead is
 not supported.
 Optical Transport Network (OTN) - G.872
 A transport network bounded by optical channel access points.
 The optical transport network layered structure is comprised of
 the optical channel, optical multiplex section and optical
 transmission section layer networks.
 According to G.872, an OTN-compliant interface is an interface
 of the optical transport network based on the architecture
 defined in G.872, while an OTN-non-compliant interface is an
 interface that does not comply with the interface
 recommendations that will be defined for the optical transport
 network based on the architecture defined in G.872.
 Optical Transmission Section Layer Network (OTS) - G.872
 This layer network provides functionality for transmission of
 optical signals on optical media of various types.
 Optical Channel Transport Unit Section Layer Network (OTUk) - G.709
 The OTUk is the layer network that provides for the transport
 of an ODUk over one or more optical channel link connections.
 It consists of the optical channel data unit and OTUk related
 overhead (FEC and overhead for management of an optical channel
 link connection). It is characterized by its frame structure,
 bit rate, and bandwidth.
 Payload Type Mismatch (PLM)
 The detection of a mismatch of payload type is based on a
 comparison between the expected Payload Type signal,
 provisioned via the management interface, and the received
 Payload Type signal.
 Trail Trace Identifier Transmitted (TxTI) - G.798
 The Trail Trace Identifier (TTI) information, provisioned by
 the managing system, to be placed in the TTI overhead position
 of the source of a trail for transmission.
 Trail Trace Identifier Accepted (AcTI) - G.798
 The Trail Trace Identifier (TTI) information accepted from the
 TTI overhead position at the sink of a trail.
 Trail Trace Identifier Accepted Status (AcTIStatus) - G.798
 The Status of the Trail Trace Identifier (TTI) accepted from
 the TTI overhead position at the sink of a trail.
 Trace Identifier Mismatch (TIM) - G.798
 The detection of TIM is based on a comparison between the
 expected Trial Trace Identifier (TTI), configured via the
 management interface, and the received TTI.
 Trace Identifier Mismatch Consequent Action Enabled (TimActEnabled) -
 G.798
 The Consequent Action function of TIM is disabled.
 Trace Identifier Mismatch Detection Mode (TimDetMode) - G.798
 The mode of detecting Trace Identifier Mismatch (TIM).
 Possible modes are:
 (1) off - no checking,
 (2) SAPI - checking the SAPI only,
 (3) DAPI - checking the DAPI only, and
 (4) Both - checking both the SAPI and DAPI.
2.6.1. Defect Conditions
 The following Defect conditions are defined in G.798 (as fault cause)
 for OTN monitoring.
 ais Alarm Indication Signal (AIS)
 bdi Backward Defect Indication (BDI)
 bdiO Backward Defect Indication - Overhead (BDI-O)
 bdiP Backward Defect Indication - Payload (BDI-P)
 deg Degraded (DEG)
 lck Locked (LCK)
 lof Loss of Frame (LOF)
 lom Loss of Multi Frame
 los Loss of Signal (LOS)
 losO Loss of Signal - Overhead (LOS-O)
 losP Loss of Signal - Payload (LOS-P)
 oci Open Connection Indication (OCI)
 plm Payload Mismatch (PLM)
 ssf Server Signal Failure (SSF)
 ssfO Server Signal Failure - Overhead (SSF-O)
 ssfP Server Signal Failure - Payload (SSF-P)
 tim Trace Identifier Mismatch (TIM)
 The relationship of these conditions within a network layer and
 between layers are described in G.798 [ITU-T G.798].
2.6.2. Performance Parameters
 To facilitate identification of equipment and facilities that may
 require maintenance, it is necessary to monitor parameters such as
 optical power at each layer. The measurements are taken
 periodically, and a snapshot of the current value is also made
 available. More specifically, performance parameters at each layer
 are maintained for the current 15-minute interval, the current 24-
 hour interval, N previous 15-minute intervals where 4 <= N <= 96, and
 one previous 24-hour interval.
 Note that some of the previous interval data will be unavailable if
 the agent has restarted within the last 24 hours.
 There is no requirement for an agent to ensure a fixed relationship
 between the start of a 15-minute or 24-hour interval and any wall
 clock; however, some agents may align the 15-minute intervals with
 quarter hours and may align the 24-hour intervals with a particular
 hour of the day (e.g., 00:00 UTC).
 Note that some DWDM systems may also monitor the laser temperature of
 the equipment in addition to monitoring the optical power. However,
 industry opinions vary widely with respect to laser temperature
 monitoring, in particular regarding the benefit of the monitoring and
 which temperatures are to be monitored (i.e., all or only some of the
 pump lasers). Similarly, there are varying opinions regarding mid-
 stage power monitoring. Since no consensus was reached, it was
 decided that the laser temperature monitoring and mid-stage
 monitoring would not be standardized in the MIB. If an
 implementation would like to monitor these parameters, one could use
 a proprietary MIB or the ENTITY-SENSOR-MIB [RFC3433] to capture this
 information.
 The sink-side monitoring points for the various layers are shown in
 Figure 7 below.
 OCh sink pre-OTN PM params
 |
 | OChGroup sink pre-OTN params
 | |
 | | OMSn sink pre-OTN PM params
 | | |
 | | | OTSn sink pre-OTN PM params
 | | | |
 V V V V
 /|
 ____/|_______/| /| / |
 \| . / |__________________/ |________________/ |_____
 . \ | ____\ | \ |
 ____/|_______\| | \| ___\ |
 \| C-Band | Demux | \|
 | |
 | |
 ____/|_______/| | OSC
 \| . / |_____________|
 . \ |
 ____/|_______\|
 \| L-Band
 optical optical optical OSC Drop Filter
 rcvr (O/E) demux demux
 OCh OChGroup OMSn OTSn
 Figure 7: Sink-side pre-OTN monitoring points
 The source-side monitoring points for the various layers are shown in
 Figure 8 below.
 OCh src pre-OTN PM params
 |
 | OChGroup src pre-OTN PM params
 | |
 | | OMSn src pre-OTN PM params
 | | |
 | | | OTSn src pre-OTN PM params
 | | | |
 V V V V
 |\
 ___|\______|\ |\ | \
 |/ . | \_________________| \______________| \______
 . | / ___| / | /
 ----|/ | |/ __| /
 C-Band MUX | Mux | |/
 | |
 | OSC
 ___|\______|\ |
 |/ . | \_____________|
 . | /
 ----|/
 L-Band MUX
 optical optical optical OSC Add Filter
 xmtr mux mux
 (E/O)
 OCh OChGroup OMSn OTSn
 Figure 8: Source-side pre-OTN monitoring points
 Note that optical performance parameters are of type Integer32,
 rather than Counter32 or Gauge32, because it is possible for these
 objects to increase or decrease and to assume negative or positive
 values.
2.7. Tandem Connection Monitoring (TCM)
 An ODUk termination can be provisioned to support (0..6) TCM levels.
 Each TCM field contains the following subfields:
 - Trail Trace Identifier (TTI)
 - Bit Interleaved Parity 8 (BIP8)
 - Backward Defect Indication (BDI)
 - Backward Error Indication (BEI)
 - Status bits indicating the presence of TCM overhead, Incoming
 AlignmentError, or a maintenance signal (STAT).
 The insertion of these subfields is controlled by:
 - optIfODUkTSourceMode or otnODUkTsinkMode
 The detection and corresponding action of these subfields are
 controlled by:
 - optIfODUkTTimDetMode
 - optIfODUkTTimActEnabled
 The TCM connection is used for monitoring the quality of an end to
 end connection or any segment, as illustrated in the example:
 TCM1 used for the end-to-end connection from A1 to A2.
 TCM2 used for segment B1-B2, then used again for segment B3-B4.
 TCM3-TCM6 these bytes are not in used in this example.
 The TCM connection can be nested (B1-B2 is nested in A1-A2) or
 cascaded (B1-B2 and B3-B4).
 ______ ______ ______ ______ ______
 |TCM6| |TCM6| |TCM6| |TCM6| |TCM6|
 |----| |----| |----| |----| |----|
 |TCM5| |TCM5| |TCM5| |TCM5| |TCM5|
 |----| |----| |----| |----| |----|
 |TCM4| |TCM4| |TCM4| |TCM4| |TCM4|
 |----| |----| |----| |----| |----|
 |TCM3| |TCM3| |TCM3| |TCM3| |TCM3|
 |----| |----| |----| |----| |----|
 |TCM2| |TCM2| |TCM2| |TCM2| |TCM2|
 |----| |----| |----| |----| |----|
 |TCM1| |TCM1| |TCM1| |TCM1| |TCM1|
 |----| |----| |----| |----| |----|
 | | | | |
 | | | | |
 | | | | |
 | | | | |
 | | | | |
 |\ |\ /| |\ /| /|
 ----> | \________| \_______/ |_________| \_____ / |______ / | ---->
 | / | / \ | | / \ | \ |
 |/ |/ \| |/ \| \|
 TCM1: A1 <------------------------------------------------> A2
 TCM2: B1 <-----> B2 B3 <-----> B4
3. Structure of the MIB
 The managed Optical Networking interface objects are arranged into
 the following groups of tables:
 The optIfOTMn group handles the OTM information structure of an
 optical interface.
 optIfOTMnTable
 The optIfPerfMon group handles the current 15-minute and 24-hour
 interval elapsed time, as well as the number of 15-minute intervals
 for all layers.
 optIfPerfMonIntervalTable
 The optIfOTSn groups handle the configuration and performance
 monitoring information for OTS layers.
 optIfOTSnConfigTable
 optIfOTSnSinkCurrentTable
 optIfOTSnSinkIntervalTable
 optIfOTSnSinkCurDayTable
 optIfOTSnSinkPrevDayTable
 optIfOTSnSrcCurrentTable
 optIfOTSnSrcIntervalTable
 optIfOTSnSrcCurDayTable
 optIfOTSnSrcPrevDayTable
 The optIfOMSn groups handle the configuration and performance
 information for OMS layers.
 optIfOMSnConfigTable
 optIfOMSnSinkCurrentTable
 optIfOMSnSinkIntervalTable
 optIfOMSnSinkCurDayTable
 optIfOMSnSinkPrevDayTable
 optIfOMSnSrcCurrentTable
 optIfOMSnSrcIntervalTable
 optIfOMSnSrcCurDayTable
 optIfOMSnSrcPrevDayTable
 The optIfOChGroup groups handle the configuration and performance
 information for OChGroup layers.
 optIfOChGroupConfigTable
 optIfOChGroupSinkCurrentTable
 optIfOChGroupSinkIntervalTable
 optIfOChGroupSinkCurDayTable
 optIfOChGroupSinkPrevDayTable
 optIfOChGroupSrcCurrentTable
 optIfOChGroupSrcIntervalTable
 optIfOChGroupSrcCurDayTable
 optIfOChGroupSrcPrevDayTable
 The optIfOCh groups handle the configuration and performance
 monitoring information for OCh layers.
 optIfOChConfigTable
 optIfOChSinkCurrentTable
 optIfOChSinkIntervalTable
 optIfOChSinkCurDayTable
 optIfOChSinkPrevDayTable
 optIfOChSrcCurrentTable
 optIfOChSrcIntervalTable
 optIfOChSrcCurDayTable
 optIfOChSrcPrevDayTable
 The optIfOTUk groups handle configuration information for OTUk.
 optIfOTUkConfigTable
 optIfGCC0ConfigTable
 The optIfODUk groups handle configuration information for ODUk.
 optIfODUkConfigTable
 optIfODUkTtpConfigTable
 optIfODUkPositionSeqTable
 optIfODUkNimConfigTable
 optIfGCC12ConfigTable
 The optIfODUkT groups handle configuration information for ODUkT.
 optIfODUkTConfigTable
 optIfODUkTNimConfigTable
 This memo does not define MIB objects for optical system cross-
 connects. After a consensus is reached on definitions of the
 interface MIB objects for optical systems (resulting from resolution
 of discussions on the objects proposed in this memo), work can
 progress on the definitions of tables to represent cross-connects
 (e.g., OCh optical cross-connects and ODUk electrical cross-
 connects).
3.1. The optIfOTMn group
3.1.1. optIfOTMnTable
 This table contains the OTM structure information of an optical
 interface.
3.2. The optIfPerfMon group
3.2.1. optIf Performance Monitoring Interval Table
 This table applies to all performance monitoring on an NE. It
 records on a per-interface basis the elapsed time in the current 15-
 minute and 24-hour interval, as well as the total number of 15-minute
 intervals and the number of invalid 15-minute intervals.
3.3. The optIfOTSn groups
3.3.1. optIfOTSn Configuration group
3.3.1.1. optIfOTSn Configuration Table
 This table contains information on configuration of optIfOTSn
 interfaces, in addition to the information on such interfaces
 contained in the ifTable.
3.3.2. optIfOTSn Pre-OTN PM group
3.3.2.1. optIfOTSn Source Current Table
 This table contains information on current performance of optIfOTSn
 interfaces contained in the ifTable.
3.3.2.2. optIfOTSn Source Interval Table
 This table contains information on historic performance of optIfOTSn
 interfaces contained in the ifTable.
3.3.2.3. optIfOTSn Source Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOTSn interfaces contained in the ifTable.
3.3.2.4. optIfOTSn Source Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOTSn interfaces contained in the ifTable.
3.3.2.5. optIfOTSn Sink Current Table
 This table contains information on current performance of optIfOTSn
 interfaces contained in the ifTable.
3.3.2.6. optIfOTSn Sink Interval Table
 This table contains information on historic performance of optIfOTSn
 interfaces contained in the ifTable.
3.3.2.7. optIfOTSn Sink Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOTSn interfaces contained in the ifTable.
3.3.2.8. optIfOTSn Sink Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOTSn interfaces contained in the ifTable.
3.4. The optIfOMSn groups
3.4.1. optIfOMSn Configuration group
3.4.1.1. optIfOMSn Configuration Table
 This table contains information on configuration of optIfOMSn
 interfaces, in addition to the information on such interfaces
 contained in the ifTable.
3.4.2. optIfOMSn Pre-OTN PM group
3.4.2.1. optIfOMSn Source Current Table
 This table contains information on current performance of optIfOMSn
 interfaces contained in the ifTable.
3.4.2.2. optIfOMSn Source Interval Table
 This table contains information on historic performance of optIfOMSn
 interfaces contained in the ifTable.
3.4.2.3. optIfOMSn Source Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOMSn interfaces contained in the ifTable.
3.4.2.4. optIfOMSn Source Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOMSn interfaces contained in the ifTable.
3.4.2.5. optIfOMSn Sink Current Table
 This table contains information on current performance of optIfOMSn
 interfaces contained in the ifTable.
3.4.2.6. optIfOMSn Sink Interval Table
 This table contains information on historic performance of optIfOMSn
 interfaces contained in the ifTable.
3.4.2.7. optIfOMSn Sink Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOMSn interfaces contained in the ifTable.
3.4.2.8. optIfOMSn Sink Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOMSn interfaces contained in the ifTable.
3.5. The optIfOChGroup groups
3.5.1. optIfOChGroup Configuration group
3.5.1.1. optIfOChGroup Configuration Table
 This table contains information on configuration of optIfOChGroup
 interfaces, in addition to the information on such interfaces
 contained in the ifTable.
3.5.2. optIfOChGroup Pre-OTN PM group
3.5.2.1. optIfOChGroup Source Current Table
 This table contains information on current performance of
 optIfOChGroup interfaces contained in the ifTable.
3.5.2.2. optIfOChGroup Source Interval Table
 This table contains information on historic performance of
 optIfOChGroup interfaces contained in the ifTable.
3.5.2.3. optIfOChGroup Source Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOChGroup interfaces contained in the ifTable.
3.5.2.4. optIfOChGroup Source Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOChGroup interfaces contained in the ifTable.
3.5.2.5. optIfOChGroup Sink Current Table
 This table contains information on current performance of
 optIfOChGroup interfaces contained in the ifTable.
3.5.2.6. optIfOChGroup Sink Interval Table
 This table contains information on historic performance of
 optIfOChGroup interfaces contained in the ifTable.
3.5.2.7. optIfOChGroup Sink Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOChGroup interfaces contained in the ifTable.
3.5.2.8. optIfOChGroup Sink Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOChGroup interfaces contained in the ifTable.
3.6. The optIfOCh groups
3.6.1. optIfOCh Configuration group
3.6.1.1. optIfOCh Configuration Table
 This table contains information on configuration of optIfOCh
 interfaces, in addition to the information on such interfaces
 contained in the ifTable.
3.6.2. optIfOCh Pre-OTN PM group
3.6.2.1. optIfOCh Source Current Table
 This table contains information on current performance of optIfOCh
 interfaces contained in the ifTable.
3.6.2.2. optIfOCh Source Interval Table
 This table contains information on historic performance of optIfOCh
 interfaces contained in the ifTable.
3.6.2.3. optIfOCh Source Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOCh interfaces contained in the ifTable.
3.6.2.4. optIfOCh Source Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOCh interfaces contained in the ifTable.
3.6.2.5. optIfOCh Sink Current Table
 This table contains information on current performance of optIfOCh
 interfaces contained in the ifTable.
3.6.2.6. optIfOCh Sink Interval Table
 This table contains information on historic performance of optIfOCh
 interfaces contained in the ifTable.
3.6.2.7. optIfOCh Sink Current Day Table
 This table contains a snapshot of information for the current 24-hour
 period for optIfOCh interfaces contained in the ifTable.
3.6.2.8. optIfOCh Sink Previous Day Table
 This table contains a snapshot of information for the previous 24-
 hour period for optIfOCh interfaces contained in the ifTable.
3.7. The optIfOTUk groups
3.7.1. optIfOTUk Configuration group
3.7.1.1. optIfOTUk Configuration Table
 This table contains information on configuration of optIfOTUk
 interfaces, in addition to the information on such interfaces
 contained in the ifTable.
3.7.2. optIfGCC0 Configuration group
3.7.2.1. optIfGCC0 Configuration Table
 This table contains information on configuration of the GCC0
 communication channel.
3.8. The optIfODUk groups
3.8.1. optIfODUk Configuration group
3.8.1.1. optIfODUk Configuration Table
 This table contains all the objects that are common to endpoints
 (called trail termination points or TTPs) and connection termination
 points (CTPs), and also includes a flag stating whether TTP functions
 are present.
3.8.2. optIfODUkTtp Configuration group
3.8.2.1. optIfODUkTtp Configuration Table
 This table contains TTP-specific information on configuration of
 optIfODUk interfaces, in addition to the information on such
 interfaces contained in the ifTable.
3.8.3. optIfODUk Position Seq group
3.8.3.1. optIfODUk Position Seq Table
 This table contains information on the position sequence of the TCM
 function and/or GCC12 access that have been created within the
 optIfODUk interfaces, in addition to the information on such
 interfaces contained in the ifTable.
3.8.4. optIfODUk Nim Configuration group
3.8.4.1. optIfODUk Nim Configuration Table
 This table contains information on configuration of optIfODUk Non-
 intrusive monitoring.
3.8.5. optIfGCC12 Configuration group
3.8.5.1. optIfGCC12 Configuration Table
 This table contains information on configuration of the GCC1 and GCC2
 communication channels.
3.9. The optIfODUkT groups
3.9.1. optIfODUkT Configuration group
3.9.1.1. optIfODUkT Configuration Table
 This table contains information on configuration of optIfODUkT
 interfaces, in addition to the information on such interfaces
 contained in the ifTable.
3.9.2. optIfODUkT Nim Configuration group
3.9.2.1. optIfODUkT Nim Configuration Table
 This table contains information on configuration of optIfODUkT Non-
 intrusive monitoring.
4. Object Definitions
OPT-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
 MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32,
 Unsigned32, transmission
 FROM SNMPv2-SMI
 TEXTUAL-CONVENTION, RowPointer, RowStatus, TruthValue
 FROM SNMPv2-TC
 SnmpAdminString
 FROM SNMP-FRAMEWORK-MIB
 MODULE-COMPLIANCE, OBJECT-GROUP
 FROM SNMPv2-CONF
 ifIndex
 FROM IF-MIB;
-- This is the MIB module for the OTN Interface objects.
optIfMibModule MODULE-IDENTITY
 LAST-UPDATED "200308130000Z"
 ORGANIZATION "IETF AToM MIB Working Group"
 CONTACT-INFO
 "WG charter:
 http://www.ietf.org/html.charters/atommib-charter.html
 Mailing Lists:
 General Discussion: atommib@research.telcordia.com
 To Subscribe: atommib-request@research.telcordia.com
 Editor: Hing-Kam Lam
 Postal: Lucent Technologies, Room 4C-616
 101 Crawfords Corner Road
 Holmdel, NJ 07733
 Tel: +1 732 949 8338
 Email: hklam@lucent.com"
 DESCRIPTION
 "The MIB module to describe pre-OTN and OTN interfaces.
 Copyright (C) The Internet Society (2003). This version
 of this MIB module is part of RFC 3591; see the RFC
 itself for full legal notices."
 REVISION "200308130000Z"
 DESCRIPTION
 "Initial version, published as RFC 3591."
 ::={ transmission 133 }
-- textual conventions
OptIfAcTI ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "The trace identifier (TI) accepted at the receiver."
 SYNTAX OCTET STRING (SIZE(64))
OptIfBitRateK ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Indicates the index 'k' that is used to
 represent a supported bit rate and the different
 versions of OPUk, ODUk and OTUk.
 Allowed values of k are defined in ITU-T G.709.
 Currently allowed values in G.709 are:
 k=1 represents an approximate bit rate of 2.5 Gbit/s,
 k=2 represents an approximate bit rate of 10 Gbit/s,
 k=3 represents an approximate bit rate of 40 Gbit/s."
 SYNTAX Integer32
OptIfDEGM ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a Degraded Signal
 defect (dDEG). A dDEG shall be declared if OptIfDEGM
 consecutive bad PM Seconds are detected."
 SYNTAX Unsigned32 (2..10)
OptIfDEGThr ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a performance
 monitoring (PM) Second to be bad. A PM Second is declared bad if
 the percentage of detected errored blocks in that second is
 greater than or equal to OptIfDEGThr."
 SYNTAX Unsigned32 (1..100)
OptIfDirectionality ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Indicates the directionality of an entity."
 SYNTAX INTEGER {
 sink(1),
 source(2),
 bidirectional(3)
 }
OptIfSinkOrSource ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Indicates the directionality of an entity
 that is allowed only to be a source or sink."
 SYNTAX INTEGER {
 sink(1),
 source(2)
 }
OptIfExDAPI ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "The Destination Access Point Identifier (DAPI)
 expected by the receiver."
 SYNTAX OCTET STRING (SIZE(16))
OptIfExSAPI ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "The Source Access Point Identifier (SAPI)
 expected by the receiver."
 SYNTAX OCTET STRING (SIZE(16))
OptIfIntervalNumber ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Uniquely identifies a 15-minute interval. The interval
 identified by 1 is the most recently completed interval, and
 the interval identified by n is the interval immediately
 preceding the one identified by n-1."
 SYNTAX Unsigned32 (1..96)
OptIfTIMDetMode ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function."
 SYNTAX INTEGER {
 off(1),
 dapi(2),
 sapi(3),
 both(4)
 }
OptIfTxTI ::= TEXTUAL-CONVENTION
 STATUS current
 DESCRIPTION
 "The trace identifier (TI) transmitted."
 SYNTAX OCTET STRING (SIZE(64))
-- object groups
optIfObjects OBJECT IDENTIFIER ::= { optIfMibModule 1 }
optIfConfs OBJECT IDENTIFIER ::= { optIfMibModule 2 }
optIfOTMn OBJECT IDENTIFIER ::= { optIfObjects 1 }
optIfPerfMon OBJECT IDENTIFIER ::= { optIfObjects 2 }
optIfOTSn OBJECT IDENTIFIER ::= { optIfObjects 3 }
optIfOMSn OBJECT IDENTIFIER ::= { optIfObjects 4 }
optIfOChGroup OBJECT IDENTIFIER ::= { optIfObjects 5 }
optIfOCh OBJECT IDENTIFIER ::= { optIfObjects 6 }
optIfOTUk OBJECT IDENTIFIER ::= { optIfObjects 7 }
optIfODUk OBJECT IDENTIFIER ::= { optIfObjects 8 }
optIfODUkT OBJECT IDENTIFIER ::= { optIfObjects 9 }
optIfGroups OBJECT IDENTIFIER ::= { optIfConfs 1 }
optIfCompl OBJECT IDENTIFIER ::= { optIfConfs 2 }
-- the optIfOTMn group
-- This group defines the OTM structure information of an
-- optical interface.
-- OTMn Table
optIfOTMnTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTMnEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTMn structure information."
 ::= { optIfOTMn 1 }
optIfOTMnEntry OBJECT-TYPE
 SYNTAX OptIfOTMnEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains the OTMn structure
 information of an optical interface."
 INDEX { ifIndex }
 ::= { optIfOTMnTable 1 }
OptIfOTMnEntry ::=
 SEQUENCE {
 optIfOTMnOrder Unsigned32,
 optIfOTMnReduced TruthValue,
 optIfOTMnBitRates BITS,
 optIfOTMnInterfaceType SnmpAdminString,
 optIfOTMnTcmMax Unsigned32,
 optIfOTMnOpticalReach INTEGER
 }
optIfOTMnOrder OBJECT-TYPE
 SYNTAX Unsigned32 (1..900)
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This object indicates the order of the OTM, which
 represents the maximum number of wavelengths that can be
 supported at the bit rate(s) supported on the interface."
 ::= { optIfOTMnEntry 1 }
optIfOTMnReduced OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This object indicates whether a reduced or full
 functionality is supported at the interface. A value of
 true means reduced. A value of false means full."
 ::= { optIfOTMnEntry 2 }
optIfOTMnBitRates OBJECT-TYPE
 SYNTAX BITS { bitRateK1(0), bitRateK2(1), bitRateK3(2) }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This attribute is a bit map representing the bit
 rate or set of bit rates supported on the interface.
 The meaning of each bit position is as follows:
 bitRateK1(0) is set if the 2.5 Gbit/s rate is supported
 bitRateK2(1) is set if the 10 Gbit/s rate is supported
 bitRateK3(2) is set if the 40 Gbit/s rate is supported
 Note that each bit position corresponds to one possible
 value of the type OptIfBitRateK.
 The default value of this attribute is system specific."
 ::= { optIfOTMnEntry 3 }
optIfOTMnInterfaceType OBJECT-TYPE
 SYNTAX SnmpAdminString
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This object identifies the type of interface. The value of
 this attribute will affect the behavior of the OTM with
 respect to presence/absence of OTM Overhead Signal (OOS)
 processing and TCM activation. For an IrDI interface,
 there is no OOS processing and TCM activation is limited
 to n levels as specified by a TCM level threshold.
 This object contains two fields that are separated by
 whitespace. The possible values are:
 field 1: one of the 4-character ASCII strings
 'IrDI' or 'IaDI'
 field 2: free-form text consisting of printable
 UTF-8 encoded characters
 Note that field 2 is optional. If it is not present then there
 is no requirement for trailing whitespace after field 1.
 The default values are as follows:
 field 1: 'IaDI'
 field 2: an empty string."
 ::= { optIfOTMnEntry 4 }
optIfOTMnTcmMax OBJECT-TYPE
 SYNTAX Unsigned32 (0..6)
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "This object identifies the maximum number of TCM
 levels allowed for any Optical Channel contained
 in this OTM. A new TCM activation will be rejected
 if the requested level is greater than the threshold.
 If InterfaceType object specifies a type of 'IaDI'
 for this OTM, then this attribute is irrelevant.
 Possible values: unsigned integers in the range
 from 0 to 6 inclusive.
 Default value: 3."
 ::= { optIfOTMnEntry 5 }
optIfOTMnOpticalReach OBJECT-TYPE
 SYNTAX INTEGER { intraOffice(1), shortHaul(2), longHaul(3),
 veryLongHaul(4), ultraLongHaul(5) }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This object indicates the length the optical signal
 may travel before requiring termination or regeneration.
 The meaning of the enumeration are:
 intraOffice(1) - intra-office (as defined in ITU-T G.957)
 shortHaul(2) - short haul (as defined in ITU-T G.957)
 longHaul(3) - long haul (as defined in ITU-T G.957)
 veryLongHaul(4) - very long haul (as defined in ITU-T G.691)
 ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691)"
 ::= { optIfOTMnEntry 6 }
-- the optIfPerfMon group
-- This group defines performance monitoring objects for all
-- layers.
-- PM interval table
optIfPerfMonIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfPerfMonIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of 15-minute performance monitoring interval
 information."
 ::= { optIfPerfMon 1 }
optIfPerfMonIntervalEntry OBJECT-TYPE
 SYNTAX OptIfPerfMonIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains 15-minute performance
 monitoring interval information of an interface."
 INDEX { ifIndex }
 ::= { optIfPerfMonIntervalTable 1 }
OptIfPerfMonIntervalEntry ::=
 SEQUENCE {
 optIfPerfMonCurrentTimeElapsed Gauge32,
 optIfPerfMonCurDayTimeElapsed Gauge32,
 optIfPerfMonIntervalNumIntervals Unsigned32,
 optIfPerfMonIntervalNumInvalidIntervals Unsigned32
 }
optIfPerfMonCurrentTimeElapsed OBJECT-TYPE
 SYNTAX Gauge32 (0..900)
 UNITS "seconds"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Number of seconds elapsed in the current 15-minute
 performance monitoring interval.
 If, for some reason, such as an adjustment in the NE's
 time-of-day clock, the number of seconds elapsed exceeds
 the maximum value, then the maximum value will be returned."
 ::= { optIfPerfMonIntervalEntry 1 }
optIfPerfMonCurDayTimeElapsed OBJECT-TYPE
 SYNTAX Gauge32 (0..86400)
 UNITS "seconds"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Number of seconds elapsed in the current 24-hour interval
 performance monitoring period.
 If, for some reason, such as an adjustment in the NE's
 time-of-day clock, the number of seconds elapsed exceeds
 the maximum value, then the maximum value will be returned."
 ::= { optIfPerfMonIntervalEntry 2 }
optIfPerfMonIntervalNumIntervals OBJECT-TYPE
 SYNTAX Unsigned32 (0..96)
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The number of 15-minute intervals for which performance
 monitoring data is available. The number is the same for all
 the associated sub layers of the interface.
 An optical interface must be capable of supporting at least
 n intervals, where n is defined as follows:
 The minimum value of n is 4.
 The default of n is 32.
 The maximum value of n is 96.
 The value of this object will be n unless performance
 monitoring was (re-)started for the interface within the last
 (n*15) minutes, in which case the value will be the number of
 complete 15-minute intervals since measurement was
 (re-)started."
 ::= { optIfPerfMonIntervalEntry 3 }
optIfPerfMonIntervalNumInvalidIntervals OBJECT-TYPE
 SYNTAX Unsigned32 (0..96)
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The number of intervals in the range from 0 to
 optIfPerfMonIntervalNumIntervals for which no performance
 monitoring data is available and/or the data is invalid."
 ::= { optIfPerfMonIntervalEntry 4 }
-- the optIfOTSn group
-- This group handles the configuration and performance
-- monitoring objects for OTS layers.
-- OTSn config table
optIfOTSnConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn configuration information."
 ::= { optIfOTSn 1 }
optIfOTSnConfigEntry OBJECT-TYPE
 SYNTAX OptIfOTSnConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfOTSnConfigTable 1 }
OptIfOTSnConfigEntry ::=
 SEQUENCE {
 optIfOTSnDirectionality OptIfDirectionality,
 optIfOTSnAprStatus SnmpAdminString,
 optIfOTSnAprControl SnmpAdminString,
 optIfOTSnTraceIdentifierTransmitted OptIfTxTI,
 optIfOTSnDAPIExpected OptIfExDAPI,
 optIfOTSnSAPIExpected OptIfExSAPI,
 optIfOTSnTraceIdentifierAccepted OptIfAcTI,
 optIfOTSnTIMDetMode OptIfTIMDetMode,
 optIfOTSnTIMActEnabled TruthValue,
 optIfOTSnCurrentStatus BITS
 }
optIfOTSnDirectionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity."
 ::= { optIfOTSnConfigEntry 1 }
optIfOTSnAprStatus OBJECT-TYPE
 SYNTAX SnmpAdminString
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This attribute indicates the status of the Automatic
 Power Reduction (APR) function of the entity. Valid
 values are 'on' and 'off'."
 ::= { optIfOTSnConfigEntry 2 }
optIfOTSnAprControl OBJECT-TYPE
 SYNTAX SnmpAdminString
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "This object is a UTF-8 encoded string that specifies Automatic
 Power Reduction (APR) control actions requested of this entity
 (when written) and that returns the current APR control state
 of this entity (when read). The values are implementation-defined.
 Any implementation that instantiates this object must document the
 set of values that it allows to be written, the set of values
 that it will return, and what each of those values means."
 ::= { optIfOTSnConfigEntry 3 }
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
 SYNTAX OptIfTxTI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The trace identifier transmitted.
 This object is applicable when optIfOTSnDirectionality has the
 value source(2) or bidirectional(3).
 This object does not apply to reduced-capability systems (i.e.,
 those for which optIfOTMnReduced has the value true(1)) or
 at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 has the value 'IrDI').
 If no value is ever set by a management entity for the object
 optIfOTSnTraceIdentifierTransmitted, system-specific default
 value will be used. Any implementation that instantiates this
 object must document the system-specific default value or how it
 is derived."
 ::= { optIfOTSnConfigEntry 4 }
optIfOTSnDAPIExpected OBJECT-TYPE
 SYNTAX OptIfExDAPI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The DAPI expected by the receiver.
 This object is applicable when optIfOTSnDirectionality has the
 value sink(1) or bidirectional(3). It has no effect if
 optIfOTSnTIMDetMode has the value off(1) or sapi(3).
 This object does not apply to reduced-capability systems (i.e.,
 those for which optIfOTMnReduced has the value true(1)) or
 at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 has the value 'IrDI')."
 ::= { optIfOTSnConfigEntry 5 }
optIfOTSnSAPIExpected OBJECT-TYPE
 SYNTAX OptIfExSAPI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The SAPI expected by the receiver.
 This object is applicable when optIfOTSnDirectionality has the
 value sink(1) or bidirectional(3). It has no effect if
 optIfOTSnTIMDetMode has the value off(1) or dapi(2).
 This object does not apply to reduced-capability systems (i.e.,
 those for which optIfOTMnReduced has the value true(1)) or
 at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 has the value 'IrDI')."
 ::= { optIfOTSnConfigEntry 6 }
optIfOTSnTraceIdentifierAccepted OBJECT-TYPE
 SYNTAX OptIfAcTI
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The actual trace identifier received.
 This object is applicable when optIfOTSnDirectionality has the
 value sink(1) or bidirectional(3). Its value is unspecified
 if optIfOTSnCurrentStatus has either or both of the
 losO(5) and los(6) bits set.
 This object does not apply to reduced-capability systems (i.e.,
 those for which optIfOTMnReduced has the value true(1)) or
 at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 has the value 'IrDI')."
 ::= { optIfOTSnConfigEntry 7 }
optIfOTSnTIMDetMode OBJECT-TYPE
 SYNTAX OptIfTIMDetMode
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function. This object is applicable
 when optIfOTSnDirectionality has the value sink(1)
 or bidirectional(3). The default value is off(1).
 This object does not apply to reduced-capability systems (i.e.,
 those for which optIfOTMnReduced has the value true(1)) or
 at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 has the value 'IrDI').
 The default value of this object is off(1)."
 ::= { optIfOTSnConfigEntry 8 }
optIfOTSnTIMActEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates whether the Trace Identifier Mismatch (TIM)
 Consequent Action function is enabled. This object
 is applicable when optIfOTSnDirectionality has the
 value sink(1) or bidirectional(3). It has no effect
 when the value of optIfOTSnTIMDetMode is off(1).
 This object does not apply to reduced-capability systems (i.e.,
 those for which optIfOTMnReduced has the value true(1)) or
 at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
 has the value 'IrDI').
 The default value of this object is false(2)."
 ::= { optIfOTSnConfigEntry 9 }
optIfOTSnCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 bdiP(0),
 bdiO(1),
 bdi(2),
 tim(3),
 losP(4),
 losO(5),
 los(6)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 This object is applicable when optIfOTSnDirectionality
 has the value sink(1) or bidirectional(3). In
 reduced-capability systems or at IrDI interfaces
 the only bit position that may be set is los(6)."
 ::= { optIfOTSnConfigEntry 10 }
-- OTSn sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOTSnSinkCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn sink performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOTSn 2 }
optIfOTSnSinkCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn sink performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOTSnSinkCurrentTable 1 }
OptIfOTSnSinkCurrentEntry ::=
 SEQUENCE {
 optIfOTSnSinkCurrentSuspectedFlag TruthValue,
 optIfOTSnSinkCurrentInputPower Integer32,
 optIfOTSnSinkCurrentLowInputPower Integer32,
 optIfOTSnSinkCurrentHighInputPower Integer32,
 optIfOTSnSinkCurrentLowerInputPowerThreshold Integer32,
 optIfOTSnSinkCurrentUpperInputPowerThreshold Integer32,
 optIfOTSnSinkCurrentOutputPower Integer32,
 optIfOTSnSinkCurrentLowOutputPower Integer32,
 optIfOTSnSinkCurrentHighOutputPower Integer32,
 optIfOTSnSinkCurrentLowerOutputPowerThreshold Integer32,
 optIfOTSnSinkCurrentUpperOutputPowerThreshold Integer32
 }
optIfOTSnSinkCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSinkCurrentEntry 1 }
optIfOTSnSinkCurrentInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the input."
 ::= { optIfOTSnSinkCurrentEntry 2 }
optIfOTSnSinkCurrentLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 current 15-minute interval."
 ::= { optIfOTSnSinkCurrentEntry 3 }
optIfOTSnSinkCurrentHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 current 15-minute interval."
 ::= { optIfOTSnSinkCurrentEntry 4 }
optIfOTSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on input power. If
 optIfOTSnSinkCurrentInputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSinkCurrentEntry 5 }
optIfOTSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on input power. If
 optIfOTSnSinkCurrentInputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSinkCurrentEntry 6 }
optIfOTSnSinkCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output."
 ::= { optIfOTSnSinkCurrentEntry 7 }
optIfOTSnSinkCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOTSnSinkCurrentEntry 8 }
optIfOTSnSinkCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOTSnSinkCurrentEntry 9 }
optIfOTSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on output power. If
 optIfOTSnSinkCurrentOutputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSinkCurrentEntry 10 }
optIfOTSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on output power. If
 optIfOTSnSinkCurrentOutputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSinkCurrentEntry 11 }
-- OTSn sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOTSnSinkIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OTSn sink performance monitoring
 information."
 ::= { optIfOTSn 3 }
optIfOTSnSinkIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn sink performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOTSnSinkIntervalNumber }
 ::= { optIfOTSnSinkIntervalTable 1 }
OptIfOTSnSinkIntervalEntry ::=
 SEQUENCE {
 optIfOTSnSinkIntervalNumber OptIfIntervalNumber,
 optIfOTSnSinkIntervalSuspectedFlag TruthValue,
 optIfOTSnSinkIntervalLastInputPower Integer32,
 optIfOTSnSinkIntervalLowInputPower Integer32,
 optIfOTSnSinkIntervalHighInputPower Integer32,
 optIfOTSnSinkIntervalLastOutputPower Integer32,
 optIfOTSnSinkIntervalLowOutputPower Integer32,
 optIfOTSnSinkIntervalHighOutputPower Integer32
 }
optIfOTSnSinkIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOTSnSinkIntervalEntry 1 }
optIfOTSnSinkIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSinkIntervalEntry 2 }
optIfOTSnSinkIntervalLastInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the input during the
 interval."
 ::= { optIfOTSnSinkIntervalEntry 3 }
optIfOTSnSinkIntervalLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 interval."
 ::= { optIfOTSnSinkIntervalEntry 4 }
optIfOTSnSinkIntervalHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 interval."
 ::= { optIfOTSnSinkIntervalEntry 5 }
optIfOTSnSinkIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 interval."
 ::= { optIfOTSnSinkIntervalEntry 6 }
optIfOTSnSinkIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 interval."
 ::= { optIfOTSnSinkIntervalEntry 7 }
optIfOTSnSinkIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 interval."
 ::= { optIfOTSnSinkIntervalEntry 8 }
-- OTSn sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOTSnSinkCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn sink performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOTSn 4 }
optIfOTSnSinkCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn sink performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOTSnSinkCurDayTable 1 }
OptIfOTSnSinkCurDayEntry ::=
 SEQUENCE {
 optIfOTSnSinkCurDaySuspectedFlag TruthValue,
 optIfOTSnSinkCurDayLowInputPower Integer32,
 optIfOTSnSinkCurDayHighInputPower Integer32,
 optIfOTSnSinkCurDayLowOutputPower Integer32,
 optIfOTSnSinkCurDayHighOutputPower Integer32
 }
optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSinkCurDayEntry 1 }
optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 current 24-hour interval."
 ::= { optIfOTSnSinkCurDayEntry 2 }
optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 current 24-hour interval."
 ::= { optIfOTSnSinkCurDayEntry 3 }
optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOTSnSinkCurDayEntry 4 }
optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOTSnSinkCurDayEntry 5 }
-- OTSn sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOTSnSinkPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn sink performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOTSn 5 }
optIfOTSnSinkPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn sink performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOTSnSinkPrevDayTable 1 }
OptIfOTSnSinkPrevDayEntry ::=
 SEQUENCE {
 optIfOTSnSinkPrevDaySuspectedFlag TruthValue,
 optIfOTSnSinkPrevDayLastInputPower Integer32,
 optIfOTSnSinkPrevDayLowInputPower Integer32,
 optIfOTSnSinkPrevDayHighInputPower Integer32,
 optIfOTSnSinkPrevDayLastOutputPower Integer32,
 optIfOTSnSinkPrevDayLowOutputPower Integer32,
 optIfOTSnSinkPrevDayHighOutputPower Integer32
 }
optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSinkPrevDayEntry 1 }
optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOTSnSinkPrevDayEntry 2 }
optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOTSnSinkPrevDayEntry 3 }
optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOTSnSinkPrevDayEntry 4 }
optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOTSnSinkPrevDayEntry 5 }
optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOTSnSinkPrevDayEntry 6 }
optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOTSnSinkPrevDayEntry 7 }
-- OTSn source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOTSnSrcCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn source performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOTSn 6 }
optIfOTSnSrcCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn source performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOTSnSrcCurrentTable 1 }
OptIfOTSnSrcCurrentEntry ::=
 SEQUENCE {
 optIfOTSnSrcCurrentSuspectedFlag TruthValue,
 optIfOTSnSrcCurrentOutputPower Integer32,
 optIfOTSnSrcCurrentLowOutputPower Integer32,
 optIfOTSnSrcCurrentHighOutputPower Integer32,
 optIfOTSnSrcCurrentLowerOutputPowerThreshold Integer32,
 optIfOTSnSrcCurrentUpperOutputPowerThreshold Integer32,
 optIfOTSnSrcCurrentInputPower Integer32,
 optIfOTSnSrcCurrentLowInputPower Integer32,
 optIfOTSnSrcCurrentHighInputPower Integer32,
 optIfOTSnSrcCurrentLowerInputPowerThreshold Integer32,
 optIfOTSnSrcCurrentUpperInputPowerThreshold Integer32
 }
optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSrcCurrentEntry 1 }
optIfOTSnSrcCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output."
 ::= { optIfOTSnSrcCurrentEntry 2 }
optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOTSnSrcCurrentEntry 3 }
optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOTSnSrcCurrentEntry 4 }
optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on output power. If
 optIfOTSnSrcCurrentOutputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSrcCurrentEntry 5 }
optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on output power. If
 optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSrcCurrentEntry 6 }
optIfOTSnSrcCurrentInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the input."
 ::= { optIfOTSnSrcCurrentEntry 7 }
optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 current 15-minute interval."
 ::= { optIfOTSnSrcCurrentEntry 8 }
optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 current 15-minute interval."
 ::= { optIfOTSnSrcCurrentEntry 9 }
optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on input power. If
 optIfOTSnSrcCurrentInputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSrcCurrentEntry 10 }
optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on input power. If
 optIfOTSnSrcCurrentInputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOTSnSrcCurrentEntry 11 }
-- OTSn source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOTSnSrcIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OTSn source performance monitoring
 information."
 ::= { optIfOTSn 7 }
optIfOTSnSrcIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn source performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOTSnSrcIntervalNumber }
 ::= { optIfOTSnSrcIntervalTable 1 }
OptIfOTSnSrcIntervalEntry ::=
 SEQUENCE {
 optIfOTSnSrcIntervalNumber OptIfIntervalNumber,
 optIfOTSnSrcIntervalSuspectedFlag TruthValue,
 optIfOTSnSrcIntervalLastOutputPower Integer32,
 optIfOTSnSrcIntervalLowOutputPower Integer32,
 optIfOTSnSrcIntervalHighOutputPower Integer32,
 optIfOTSnSrcIntervalLastInputPower Integer32,
 optIfOTSnSrcIntervalLowInputPower Integer32,
 optIfOTSnSrcIntervalHighInputPower Integer32
 }
optIfOTSnSrcIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOTSnSrcIntervalEntry 1 }
optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSrcIntervalEntry 2 }
optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 interval."
 ::= { optIfOTSnSrcIntervalEntry 3 }
optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 interval."
 ::= { optIfOTSnSrcIntervalEntry 4 }
optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 interval."
 ::= { optIfOTSnSrcIntervalEntry 5 }
optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the input during the
 interval."
 ::= { optIfOTSnSrcIntervalEntry 6 }
optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 interval."
 ::= { optIfOTSnSrcIntervalEntry 7 }
optIfOTSnSrcIntervalHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 interval."
 ::= { optIfOTSnSrcIntervalEntry 8 }
-- OTSn source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOTSnSrcCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn source performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOTSn 8 }
optIfOTSnSrcCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn source performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOTSnSrcCurDayTable 1 }
OptIfOTSnSrcCurDayEntry ::=
 SEQUENCE {
 optIfOTSnSrcCurDaySuspectedFlag TruthValue,
 optIfOTSnSrcCurDayLowOutputPower Integer32,
 optIfOTSnSrcCurDayHighOutputPower Integer32,
 optIfOTSnSrcCurDayLowInputPower Integer32,
 optIfOTSnSrcCurDayHighInputPower Integer32
 }
optIfOTSnSrcCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSrcCurDayEntry 1 }
optIfOTSnSrcCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOTSnSrcCurDayEntry 2 }
optIfOTSnSrcCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOTSnSrcCurDayEntry 3 }
optIfOTSnSrcCurDayLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 current 24-hour interval."
 ::= { optIfOTSnSrcCurDayEntry 4 }
optIfOTSnSrcCurDayHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 current 24-hour interval."
 ::= { optIfOTSnSrcCurDayEntry 5 }
-- OTSn source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOTSnSrcPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTSnSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTSn source performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOTSn 9 }
optIfOTSnSrcPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOTSnSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTSn source performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOTSnSrcPrevDayTable 1 }
OptIfOTSnSrcPrevDayEntry ::=
 SEQUENCE {
 optIfOTSnSrcPrevDaySuspectedFlag TruthValue,
 optIfOTSnSrcPrevDayLastOutputPower Integer32,
 optIfOTSnSrcPrevDayLowOutputPower Integer32,
 optIfOTSnSrcPrevDayHighOutputPower Integer32,
 optIfOTSnSrcPrevDayLastInputPower Integer32,
 optIfOTSnSrcPrevDayLowInputPower Integer32,
 optIfOTSnSrcPrevDayHighInputPower Integer32
 }
optIfOTSnSrcPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOTSnSrcPrevDayEntry 1 }
optIfOTSnSrcPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOTSnSrcPrevDayEntry 2 }
optIfOTSnSrcPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOTSnSrcPrevDayEntry 3 }
optIfOTSnSrcPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOTSnSrcPrevDayEntry 4 }
optIfOTSnSrcPrevDayLastInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOTSnSrcPrevDayEntry 5 }
optIfOTSnSrcPrevDayLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOTSnSrcPrevDayEntry 6 }
optIfOTSnSrcPrevDayHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOTSnSrcPrevDayEntry 7 }
-- the optIfOMSn group
-- This group handles the configuration and performance monitoring
-- information for OMS layers.
-- OMSn config table
optIfOMSnConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn configuration information."
 ::= { optIfOMSn 1 }
optIfOMSnConfigEntry OBJECT-TYPE
 SYNTAX OptIfOMSnConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfOMSnConfigTable 1 }
OptIfOMSnConfigEntry ::=
 SEQUENCE {
 optIfOMSnDirectionality OptIfDirectionality,
 optIfOMSnCurrentStatus BITS
 }
optIfOMSnDirectionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity."
 ::= { optIfOMSnConfigEntry 1 }
optIfOMSnCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 ssfP(0),
 ssfO(1),
 ssf(2),
 bdiP(3),
 bdiO(4),
 bdi(5),
 losP(6)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 This object is applicable only to full capability
 systems whose interface type is IaDI and for which
 optIfOMSnDirectionality has the value sink(1) or
 bidirectional(3)."
 ::= { optIfOMSnConfigEntry 2 }
-- OMSn sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOMSnSinkCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn sink performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOMSn 2 }
optIfOMSnSinkCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn sink performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOMSnSinkCurrentTable 1 }
OptIfOMSnSinkCurrentEntry ::=
 SEQUENCE {
 optIfOMSnSinkCurrentSuspectedFlag TruthValue,
 optIfOMSnSinkCurrentAggregatedInputPower Integer32,
 optIfOMSnSinkCurrentLowAggregatedInputPower Integer32,
 optIfOMSnSinkCurrentHighAggregatedInputPower Integer32,
 optIfOMSnSinkCurrentLowerInputPowerThreshold Integer32,
 optIfOMSnSinkCurrentUpperInputPowerThreshold Integer32,
 optIfOMSnSinkCurrentOutputPower Integer32,
 optIfOMSnSinkCurrentLowOutputPower Integer32,
 optIfOMSnSinkCurrentHighOutputPower Integer32,
 optIfOMSnSinkCurrentLowerOutputPowerThreshold Integer32,
 optIfOMSnSinkCurrentUpperOutputPowerThreshold Integer32
 }
optIfOMSnSinkCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSinkCurrentEntry 1 }
optIfOMSnSinkCurrentAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The aggregated optical power of all the DWDM input
 channels."
 ::= { optIfOMSnSinkCurrentEntry 2 }
optIfOMSnSinkCurrentLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels during the current 15-minute interval."
 ::= { optIfOMSnSinkCurrentEntry 3 }
optIfOMSnSinkCurrentHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels during the current 15-minute interval."
 ::= { optIfOMSnSinkCurrentEntry 4 }
optIfOMSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on aggregated input power. If
 optIfOMSnSinkCurrentAggregatedInputPower drops to this value
 or below, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSinkCurrentEntry 5 }
optIfOMSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on aggregated input power. If
 optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
 this value, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSinkCurrentEntry 6 }
optIfOMSnSinkCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output."
 ::= { optIfOMSnSinkCurrentEntry 7 }
optIfOMSnSinkCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output
 during the current 15-minute interval."
 ::= { optIfOMSnSinkCurrentEntry 8 }
optIfOMSnSinkCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output
 during the current 15-minute interval."
 ::= { optIfOMSnSinkCurrentEntry 9 }
optIfOMSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on output power. If
 optIfOMSnSinkCurrentOutputPower drops to this value
 or below, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSinkCurrentEntry 10 }
optIfOMSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on output power. If
 optIfOMSnSinkCurrentOutputPower reaches or exceeds
 this value, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSinkCurrentEntry 11 }
-- OMSn sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOMSnSinkIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OMSn sink performance monitoring
 information."
 ::= { optIfOMSn 3 }
optIfOMSnSinkIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn sink performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOMSnSinkIntervalNumber }
 ::= { optIfOMSnSinkIntervalTable 1 }
OptIfOMSnSinkIntervalEntry ::=
 SEQUENCE {
 optIfOMSnSinkIntervalNumber OptIfIntervalNumber,
 optIfOMSnSinkIntervalSuspectedFlag TruthValue,
 optIfOMSnSinkIntervalLastAggregatedInputPower Integer32,
 optIfOMSnSinkIntervalLowAggregatedInputPower Integer32,
 optIfOMSnSinkIntervalHighAggregatedInputPower Integer32,
 optIfOMSnSinkIntervalLastOutputPower Integer32,
 optIfOMSnSinkIntervalLowOutputPower Integer32,
 optIfOMSnSinkIntervalHighOutputPower Integer32
 }
optIfOMSnSinkIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOMSnSinkIntervalEntry 1 }
optIfOMSnSinkIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSinkIntervalEntry 2 }
optIfOMSnSinkIntervalLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power of all the DWDM input
 channels during the interval."
 ::= { optIfOMSnSinkIntervalEntry 3 }
optIfOMSnSinkIntervalLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels during the interval."
 ::= { optIfOMSnSinkIntervalEntry 4 }
optIfOMSnSinkIntervalHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels during the interval."
 ::= { optIfOMSnSinkIntervalEntry 5 }
optIfOMSnSinkIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power at the output
 during the interval."
 ::= { optIfOMSnSinkIntervalEntry 6 }
optIfOMSnSinkIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power at the output
 during the interval."
 ::= { optIfOMSnSinkIntervalEntry 7 }
optIfOMSnSinkIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power at the output
 during the interval."
 ::= { optIfOMSnSinkIntervalEntry 8 }
-- OMSn sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOMSnSinkCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn sink performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOMSn 4 }
optIfOMSnSinkCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn sink performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOMSnSinkCurDayTable 1 }
OptIfOMSnSinkCurDayEntry ::=
 SEQUENCE {
 optIfOMSnSinkCurDaySuspectedFlag TruthValue,
 optIfOMSnSinkCurDayLowAggregatedInputPower Integer32,
 optIfOMSnSinkCurDayHighAggregatedInputPower Integer32,
 optIfOMSnSinkCurDayLowOutputPower Integer32,
 optIfOMSnSinkCurDayHighOutputPower Integer32
 }
optIfOMSnSinkCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSinkCurDayEntry 1 }
optIfOMSnSinkCurDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels during the current 24-hour interval."
 ::= { optIfOMSnSinkCurDayEntry 2 }
optIfOMSnSinkCurDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels during the current 24-hour interval."
 ::= { optIfOMSnSinkCurDayEntry 3 }
optIfOMSnSinkCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power at the output
 during the current 24-hour interval."
 ::= { optIfOMSnSinkCurDayEntry 4 }
optIfOMSnSinkCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power at the output
 during the current 24-hour interval."
 ::= { optIfOMSnSinkCurDayEntry 5 }
-- OMSn sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOMSnSinkPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn sink performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOMSn 5 }
optIfOMSnSinkPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn sink performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOMSnSinkPrevDayTable 1 }
OptIfOMSnSinkPrevDayEntry ::=
 SEQUENCE {
 optIfOMSnSinkPrevDaySuspectedFlag TruthValue,
 optIfOMSnSinkPrevDayLastAggregatedInputPower Integer32,
 optIfOMSnSinkPrevDayLowAggregatedInputPower Integer32,
 optIfOMSnSinkPrevDayHighAggregatedInputPower Integer32,
 optIfOMSnSinkPrevDayLastOutputPower Integer32,
 optIfOMSnSinkPrevDayLowOutputPower Integer32,
 optIfOMSnSinkPrevDayHighOutputPower Integer32
 }
optIfOMSnSinkPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSinkPrevDayEntry 1 }
optIfOMSnSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power of all the DWDM input
 channels during the previous 24-hour interval."
 ::= { optIfOMSnSinkPrevDayEntry 2 }
optIfOMSnSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels during the previous 24-hour interval."
 ::= { optIfOMSnSinkPrevDayEntry 3 }
optIfOMSnSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels during the previous 24-hour interval."
 ::= { optIfOMSnSinkPrevDayEntry 4 }
optIfOMSnSinkPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power at the output
 during the previous 24-hour interval."
 ::= { optIfOMSnSinkPrevDayEntry 5 }
optIfOMSnSinkPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power at the output
 during the previous 24-hour interval."
 ::= { optIfOMSnSinkPrevDayEntry 6 }
optIfOMSnSinkPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power at the output
 during the previous 24-hour interval."
 ::= { optIfOMSnSinkPrevDayEntry 7 }
-- OMSn source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOMSnSrcCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn source performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOMSn 6 }
optIfOMSnSrcCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn source performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOMSnSrcCurrentTable 1 }
OptIfOMSnSrcCurrentEntry ::=
 SEQUENCE {
 optIfOMSnSrcCurrentSuspectedFlag TruthValue,
 optIfOMSnSrcCurrentOutputPower Integer32,
 optIfOMSnSrcCurrentLowOutputPower Integer32,
 optIfOMSnSrcCurrentHighOutputPower Integer32,
 optIfOMSnSrcCurrentLowerOutputPowerThreshold Integer32,
 optIfOMSnSrcCurrentUpperOutputPowerThreshold Integer32,
 optIfOMSnSrcCurrentAggregatedInputPower Integer32,
 optIfOMSnSrcCurrentLowAggregatedInputPower Integer32,
 optIfOMSnSrcCurrentHighAggregatedInputPower Integer32,
 optIfOMSnSrcCurrentLowerInputPowerThreshold Integer32,
 optIfOMSnSrcCurrentUpperInputPowerThreshold Integer32
 }
optIfOMSnSrcCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSrcCurrentEntry 1 }
optIfOMSnSrcCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output."
 ::= { optIfOMSnSrcCurrentEntry 2 }
optIfOMSnSrcCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOMSnSrcCurrentEntry 3 }
optIfOMSnSrcCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOMSnSrcCurrentEntry 4 }
optIfOMSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on output power. If
 optIfOMSnSrcCurrentOutputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSrcCurrentEntry 5 }
optIfOMSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on output power. If
 optIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSrcCurrentEntry 6 }
optIfOMSnSrcCurrentAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The aggregated optical power at the input."
 ::= { optIfOMSnSrcCurrentEntry 7 }
optIfOMSnSrcCurrentLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power at the input
 during the current 15-minute interval."
 ::= { optIfOMSnSrcCurrentEntry 8 }
optIfOMSnSrcCurrentHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power at the input
 during the current 15-minute interval."
 ::= { optIfOMSnSrcCurrentEntry 9 }
optIfOMSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on aggregated input power. If
 optIfOMSnSrcCurrentAggregatedInputPower drops to this value
 or below, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSrcCurrentEntry 10 }
optIfOMSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on aggregated input power. If
 optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds
 this value, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOMSnSrcCurrentEntry 11 }
-- OMSn source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOMSnSrcIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OMSn source performance monitoring
 information."
 ::= { optIfOMSn 7 }
optIfOMSnSrcIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn source performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOMSnSrcIntervalNumber }
 ::= { optIfOMSnSrcIntervalTable 1 }
OptIfOMSnSrcIntervalEntry ::=
 SEQUENCE {
 optIfOMSnSrcIntervalNumber OptIfIntervalNumber,
 optIfOMSnSrcIntervalSuspectedFlag TruthValue,
 optIfOMSnSrcIntervalLastOutputPower Integer32,
 optIfOMSnSrcIntervalLowOutputPower Integer32,
 optIfOMSnSrcIntervalHighOutputPower Integer32,
 optIfOMSnSrcIntervalLastAggregatedInputPower Integer32,
 optIfOMSnSrcIntervalLowAggregatedInputPower Integer32,
 optIfOMSnSrcIntervalHighAggregatedInputPower Integer32
 }
optIfOMSnSrcIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOMSnSrcIntervalEntry 1 }
optIfOMSnSrcIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSrcIntervalEntry 2 }
optIfOMSnSrcIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 interval."
 ::= { optIfOMSnSrcIntervalEntry 3 }
optIfOMSnSrcIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 interval."
 ::= { optIfOMSnSrcIntervalEntry 4 }
optIfOMSnSrcIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 interval."
 ::= { optIfOMSnSrcIntervalEntry 5 }
optIfOMSnSrcIntervalLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power at the input
 during the interval."
 ::= { optIfOMSnSrcIntervalEntry 6 }
optIfOMSnSrcIntervalLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power at the input
 during the interval."
 ::= { optIfOMSnSrcIntervalEntry 7 }
optIfOMSnSrcIntervalHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power at the input
 during the interval."
 ::= { optIfOMSnSrcIntervalEntry 8 }
-- OMSn source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOMSnSrcCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn source performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOMSn 8 }
optIfOMSnSrcCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn source performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOMSnSrcCurDayTable 1 }
OptIfOMSnSrcCurDayEntry ::=
 SEQUENCE {
 optIfOMSnSrcCurDaySuspectedFlag TruthValue,
 optIfOMSnSrcCurDayLowOutputPower Integer32,
 optIfOMSnSrcCurDayHighOutputPower Integer32,
 optIfOMSnSrcCurDayLowAggregatedInputPower Integer32,
 optIfOMSnSrcCurDayHighAggregatedInputPower Integer32
 }
optIfOMSnSrcCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSrcCurDayEntry 1 }
optIfOMSnSrcCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOMSnSrcCurDayEntry 2 }
optIfOMSnSrcCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOMSnSrcCurDayEntry 3 }
optIfOMSnSrcCurDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power at the input
 during the current 24-hour interval."
 ::= { optIfOMSnSrcCurDayEntry 4 }
optIfOMSnSrcCurDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power at the input
 during the current 24-hour interval."
 ::= { optIfOMSnSrcCurDayEntry 5 }
-- OMSn source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOMSnSrcPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOMSnSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OMSn source performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOMSn 9 }
optIfOMSnSrcPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOMSnSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OMSn source performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOMSnSrcPrevDayTable 1 }
OptIfOMSnSrcPrevDayEntry ::=
 SEQUENCE {
 optIfOMSnSrcPrevDaySuspectedFlag TruthValue,
 optIfOMSnSrcPrevDayLastOutputPower Integer32,
 optIfOMSnSrcPrevDayLowOutputPower Integer32,
 optIfOMSnSrcPrevDayHighOutputPower Integer32,
 optIfOMSnSrcPrevDayLastAggregatedInputPower Integer32,
 optIfOMSnSrcPrevDayLowAggregatedInputPower Integer32,
 optIfOMSnSrcPrevDayHighAggregatedInputPower Integer32
 }
optIfOMSnSrcPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOMSnSrcPrevDayEntry 1 }
optIfOMSnSrcPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOMSnSrcPrevDayEntry 2 }
optIfOMSnSrcPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOMSnSrcPrevDayEntry 3 }
optIfOMSnSrcPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOMSnSrcPrevDayEntry 4 }
optIfOMSnSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power at the input during the
 previous 24-hour interval."
 ::= { optIfOMSnSrcPrevDayEntry 5 }
optIfOMSnSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power at the input during the
 previous 24-hour interval."
 ::= { optIfOMSnSrcPrevDayEntry 6 }
optIfOMSnSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power at the input during the
 previous 24-hour interval."
 ::= { optIfOMSnSrcPrevDayEntry 7 }
-- the optIfOChGroup group
-- This group handles the configuration and performance monitoring
-- information for OChGroup layers.
-- OChGroup config table
optIfOChGroupConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup configuration information."
 ::= { optIfOChGroup 1 }
optIfOChGroupConfigEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfOChGroupConfigTable 1 }
OptIfOChGroupConfigEntry ::=
 SEQUENCE {
 optIfOChGroupDirectionality OptIfDirectionality
 }
optIfOChGroupDirectionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity."
 ::= { optIfOChGroupConfigEntry 1 }
-- OChGroup sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChGroupSinkCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup sink performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOChGroup 2 }
optIfOChGroupSinkCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup sink performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOChGroupSinkCurrentTable 1 }
OptIfOChGroupSinkCurrentEntry ::=
 SEQUENCE {
 optIfOChGroupSinkCurrentSuspectedFlag TruthValue,
 optIfOChGroupSinkCurrentAggregatedInputPower Integer32,
 optIfOChGroupSinkCurrentLowAggregatedInputPower Integer32,
 optIfOChGroupSinkCurrentHighAggregatedInputPower Integer32,
 optIfOChGroupSinkCurrentLowerInputPowerThreshold Integer32,
 optIfOChGroupSinkCurrentUpperInputPowerThreshold Integer32,
 optIfOChGroupSinkCurrentOutputPower Integer32,
 optIfOChGroupSinkCurrentLowOutputPower Integer32,
 optIfOChGroupSinkCurrentHighOutputPower Integer32,
 optIfOChGroupSinkCurrentLowerOutputPowerThreshold Integer32,
 optIfOChGroupSinkCurrentUpperOutputPowerThreshold Integer32
 }
optIfOChGroupSinkCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSinkCurrentEntry 1 }
optIfOChGroupSinkCurrentAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The aggregated optical power of all the DWDM input
 channels in the OChGroup."
 ::= { optIfOChGroupSinkCurrentEntry 2 }
optIfOChGroupSinkCurrentLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels in the OChGroup during the current 15-minute interval."
 ::= { optIfOChGroupSinkCurrentEntry 3 }
optIfOChGroupSinkCurrentHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels in the OChGroup during the current 15-minute interval."
 ::= { optIfOChGroupSinkCurrentEntry 4 }
optIfOChGroupSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on aggregated input power. If
 optIfOChGroupSinkCurrentAggregatedInputPower drops to this value
 or below, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSinkCurrentEntry 5 }
optIfOChGroupSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on aggregated input power. If
 optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds
 this value, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSinkCurrentEntry 6 }
optIfOChGroupSinkCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output
 in the OChGroup."
 ::= { optIfOChGroupSinkCurrentEntry 7 }
optIfOChGroupSinkCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output
 in the OChGroup during the current 15-minute interval."
 ::= { optIfOChGroupSinkCurrentEntry 8 }
optIfOChGroupSinkCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output
 in the OChGroup during the current 15-minute interval."
 ::= { optIfOChGroupSinkCurrentEntry 9 }
optIfOChGroupSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on the output power. If
 optIfOChGroupSinkCurrentOutputPower drops to this value
 or below, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSinkCurrentEntry 10 }
optIfOChGroupSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on the output power. If
 optIfOChGroupSinkCurrentOutputPower reaches or exceeds
 this value, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSinkCurrentEntry 11 }
-- OChGroup sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChGroupSinkIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OChGroup sink performance monitoring
 information."
 ::= { optIfOChGroup 3 }
optIfOChGroupSinkIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup sink performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOChGroupSinkIntervalNumber }
 ::= { optIfOChGroupSinkIntervalTable 1 }
OptIfOChGroupSinkIntervalEntry ::=
 SEQUENCE {
 optIfOChGroupSinkIntervalNumber OptIfIntervalNumber,
 optIfOChGroupSinkIntervalSuspectedFlag TruthValue,
 optIfOChGroupSinkIntervalLastAggregatedInputPower Integer32,
 optIfOChGroupSinkIntervalLowAggregatedInputPower Integer32,
 optIfOChGroupSinkIntervalHighAggregatedInputPower Integer32,
 optIfOChGroupSinkIntervalLastOutputPower Integer32,
 optIfOChGroupSinkIntervalLowOutputPower Integer32,
 optIfOChGroupSinkIntervalHighOutputPower Integer32
 }
optIfOChGroupSinkIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOChGroupSinkIntervalEntry 1 }
optIfOChGroupSinkIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSinkIntervalEntry 2 }
optIfOChGroupSinkIntervalLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power of all the DWDM input
 channels in the OChGroup during the interval."
 ::= { optIfOChGroupSinkIntervalEntry 3 }
optIfOChGroupSinkIntervalLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels in the OChGroup during the interval."
 ::= { optIfOChGroupSinkIntervalEntry 4 }
optIfOChGroupSinkIntervalHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels in the OChGroup during the interval."
 ::= { optIfOChGroupSinkIntervalEntry 5 }
optIfOChGroupSinkIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output
 in the OChGroup during the interval."
 ::= { optIfOChGroupSinkIntervalEntry 6 }
optIfOChGroupSinkIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output
 in the OChGroup during the interval."
 ::= { optIfOChGroupSinkIntervalEntry 7 }
optIfOChGroupSinkIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output
 in the OChGroup during the interval."
 ::= { optIfOChGroupSinkIntervalEntry 8 }
-- OChGroup sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChGroupSinkCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup sink performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOChGroup 4 }
optIfOChGroupSinkCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup sink performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChGroupSinkCurDayTable 1 }
OptIfOChGroupSinkCurDayEntry ::=
 SEQUENCE {
 optIfOChGroupSinkCurDaySuspectedFlag TruthValue,
 optIfOChGroupSinkCurDayLowAggregatedInputPower Integer32,
 optIfOChGroupSinkCurDayHighAggregatedInputPower Integer32,
 optIfOChGroupSinkCurDayLowOutputPower Integer32,
 optIfOChGroupSinkCurDayHighOutputPower Integer32
 }
optIfOChGroupSinkCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSinkCurDayEntry 1 }
optIfOChGroupSinkCurDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels in the OChGroup during the current 24-hour interval."
 ::= { optIfOChGroupSinkCurDayEntry 2 }
optIfOChGroupSinkCurDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels in the OChGroup during the current 24-hour interval."
 ::= { optIfOChGroupSinkCurDayEntry 3 }
optIfOChGroupSinkCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output
 in the OChGroup during the current 24-hour interval."
 ::= { optIfOChGroupSinkCurDayEntry 4 }
optIfOChGroupSinkCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output
 in the OChGroup during the current 24-hour interval."
 ::= { optIfOChGroupSinkCurDayEntry 5 }
-- OChGroup sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChGroupSinkPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup sink performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOChGroup 5 }
optIfOChGroupSinkPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup sink performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChGroupSinkPrevDayTable 1 }
OptIfOChGroupSinkPrevDayEntry ::=
 SEQUENCE {
 optIfOChGroupSinkPrevDaySuspectedFlag TruthValue,
 optIfOChGroupSinkPrevDayLastAggregatedInputPower Integer32,
 optIfOChGroupSinkPrevDayLowAggregatedInputPower Integer32,
 optIfOChGroupSinkPrevDayHighAggregatedInputPower Integer32,
 optIfOChGroupSinkPrevDayLastOutputPower Integer32,
 optIfOChGroupSinkPrevDayLowOutputPower Integer32,
 optIfOChGroupSinkPrevDayHighOutputPower Integer32
 }
optIfOChGroupSinkPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSinkPrevDayEntry 1 }
optIfOChGroupSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power of all the DWDM input
 channels in the OChGroup during the previous 24-hour interval."
 ::= { optIfOChGroupSinkPrevDayEntry 2 }
optIfOChGroupSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power of all the DWDM input
 channels in the OChGroup during the previous 24-hour interval."
 ::= { optIfOChGroupSinkPrevDayEntry 3 }
optIfOChGroupSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power of all the DWDM input
 channels in the OChGroup during the previous 24-hour interval."
 ::= { optIfOChGroupSinkPrevDayEntry 4 }
optIfOChGroupSinkPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output
 in the OChGroup during the previous 24-hour interval."
 ::= { optIfOChGroupSinkPrevDayEntry 5 }
optIfOChGroupSinkPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output
 in the OChGroup during the previous 24-hour interval."
 ::= { optIfOChGroupSinkPrevDayEntry 6 }
optIfOChGroupSinkPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output
 in the OChGroup during the previous 24-hour interval."
 ::= { optIfOChGroupSinkPrevDayEntry 7 }
-- OChGroup source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChGroupSrcCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup source performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOChGroup 6 }
optIfOChGroupSrcCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup source performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOChGroupSrcCurrentTable 1 }
OptIfOChGroupSrcCurrentEntry ::=
 SEQUENCE {
 optIfOChGroupSrcCurrentSuspectedFlag TruthValue,
 optIfOChGroupSrcCurrentOutputPower Integer32,
 optIfOChGroupSrcCurrentLowOutputPower Integer32,
 optIfOChGroupSrcCurrentHighOutputPower Integer32,
 optIfOChGroupSrcCurrentLowerOutputPowerThreshold Integer32,
 optIfOChGroupSrcCurrentUpperOutputPowerThreshold Integer32,
 optIfOChGroupSrcCurrentAggregatedInputPower Integer32,
 optIfOChGroupSrcCurrentLowAggregatedInputPower Integer32,
 optIfOChGroupSrcCurrentHighAggregatedInputPower Integer32,
 optIfOChGroupSrcCurrentLowerInputPowerThreshold Integer32,
 optIfOChGroupSrcCurrentUpperInputPowerThreshold Integer32
 }
optIfOChGroupSrcCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSrcCurrentEntry 1 }
optIfOChGroupSrcCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output."
 ::= { optIfOChGroupSrcCurrentEntry 2 }
optIfOChGroupSrcCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOChGroupSrcCurrentEntry 3 }
optIfOChGroupSrcCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOChGroupSrcCurrentEntry 4 }
optIfOChGroupSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on output power. If
 optIfOChGroupSrcCurrentOutputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSrcCurrentEntry 5 }
optIfOChGroupSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on output power. If
 optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSrcCurrentEntry 6 }
optIfOChGroupSrcCurrentAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The aggregated optical power monitored at the input."
 ::= { optIfOChGroupSrcCurrentEntry 7 }
optIfOChGroupSrcCurrentLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power monitored at the input
 during the current 15-minute interval."
 ::= { optIfOChGroupSrcCurrentEntry 8 }
optIfOChGroupSrcCurrentHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power monitored at the input
 during the current 15-minute interval."
 ::= { optIfOChGroupSrcCurrentEntry 9 }
optIfOChGroupSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on input power. If
 optIfOChGroupSrcCurrentAggregatedInputPower drops to this value
 or below, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSrcCurrentEntry 10 }
optIfOChGroupSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on input power. If
 optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds
 this value, a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChGroupSrcCurrentEntry 11 }
-- OChGroup source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChGroupSrcIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OChGroup source performance monitoring
 information."
 ::= { optIfOChGroup 7 }
optIfOChGroupSrcIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup source performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOChGroupSrcIntervalNumber }
 ::= { optIfOChGroupSrcIntervalTable 1 }
OptIfOChGroupSrcIntervalEntry ::=
 SEQUENCE {
 optIfOChGroupSrcIntervalNumber OptIfIntervalNumber,
 optIfOChGroupSrcIntervalSuspectedFlag TruthValue,
 optIfOChGroupSrcIntervalLastOutputPower Integer32,
 optIfOChGroupSrcIntervalLowOutputPower Integer32,
 optIfOChGroupSrcIntervalHighOutputPower Integer32,
 optIfOChGroupSrcIntervalLastAggregatedInputPower Integer32,
 optIfOChGroupSrcIntervalLowAggregatedInputPower Integer32,
 optIfOChGroupSrcIntervalHighAggregatedInputPower Integer32
 }
optIfOChGroupSrcIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOChGroupSrcIntervalEntry 1 }
optIfOChGroupSrcIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSrcIntervalEntry 2 }
optIfOChGroupSrcIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 interval."
 ::= { optIfOChGroupSrcIntervalEntry 3 }
optIfOChGroupSrcIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 interval."
 ::= { optIfOChGroupSrcIntervalEntry 4 }
optIfOChGroupSrcIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 interval."
 ::= { optIfOChGroupSrcIntervalEntry 5 }
optIfOChGroupSrcIntervalLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power monitored at the input
 during the interval."
 ::= { optIfOChGroupSrcIntervalEntry 6 }
optIfOChGroupSrcIntervalLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power monitored at the input
 during the interval."
 ::= { optIfOChGroupSrcIntervalEntry 7 }
optIfOChGroupSrcIntervalHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power monitored at the input
 during the interval."
 ::= { optIfOChGroupSrcIntervalEntry 8 }
-- OChGroup source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChGroupSrcCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup source performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOChGroup 8 }
optIfOChGroupSrcCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup source performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChGroupSrcCurDayTable 1 }
OptIfOChGroupSrcCurDayEntry ::=
 SEQUENCE {
 optIfOChGroupSrcCurDaySuspectedFlag TruthValue,
 optIfOChGroupSrcCurDayLowOutputPower Integer32,
 optIfOChGroupSrcCurDayHighOutputPower Integer32,
 optIfOChGroupSrcCurDayLowAggregatedInputPower Integer32,
 optIfOChGroupSrcCurDayHighAggregatedInputPower Integer32
 }
optIfOChGroupSrcCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSrcCurDayEntry 1 }
optIfOChGroupSrcCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOChGroupSrcCurDayEntry 2 }
optIfOChGroupSrcCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOChGroupSrcCurDayEntry 3 }
optIfOChGroupSrcCurDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power monitored at the input
 during the current 24-hour interval."
 ::= { optIfOChGroupSrcCurDayEntry 4 }
optIfOChGroupSrcCurDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power monitored at the input
 during the current 24-hour interval."
 ::= { optIfOChGroupSrcCurDayEntry 5 }
-- OChGroup source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChGroupSrcPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChGroupSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OChGroup source performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOChGroup 9 }
optIfOChGroupSrcPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOChGroupSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OChGroup source performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChGroupSrcPrevDayTable 1 }
OptIfOChGroupSrcPrevDayEntry ::=
 SEQUENCE {
 optIfOChGroupSrcPrevDaySuspectedFlag TruthValue,
 optIfOChGroupSrcPrevDayLastOutputPower Integer32,
 optIfOChGroupSrcPrevDayLowOutputPower Integer32,
 optIfOChGroupSrcPrevDayHighOutputPower Integer32,
 optIfOChGroupSrcPrevDayLastAggregatedInputPower Integer32,
 optIfOChGroupSrcPrevDayLowAggregatedInputPower Integer32,
 optIfOChGroupSrcPrevDayHighAggregatedInputPower Integer32
 }
optIfOChGroupSrcPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChGroupSrcPrevDayEntry 1 }
optIfOChGroupSrcPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOChGroupSrcPrevDayEntry 2 }
optIfOChGroupSrcPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOChGroupSrcPrevDayEntry 3 }
optIfOChGroupSrcPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOChGroupSrcPrevDayEntry 4 }
optIfOChGroupSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last aggregated optical power monitored at the input
 during the previous 24-hour interval."
 ::= { optIfOChGroupSrcPrevDayEntry 5 }
optIfOChGroupSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest aggregated optical power monitored at the input
 during the previous 24-hour interval."
 ::= { optIfOChGroupSrcPrevDayEntry 6 }
optIfOChGroupSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest aggregated optical power monitored at the input
 during the previous 24-hour interval."
 ::= { optIfOChGroupSrcPrevDayEntry 7 }
-- the optIfOCh group
-- This group handles the configuration and
-- performance monitoring information for OCh layers.
-- OCh config table
optIfOChConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh configuration information."
 ::= { optIfOCh 1 }
optIfOChConfigEntry OBJECT-TYPE
 SYNTAX OptIfOChConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfOChConfigTable 1 }
OptIfOChConfigEntry ::=
 SEQUENCE {
 optIfOChDirectionality OptIfDirectionality,
 optIfOChCurrentStatus BITS
 }
optIfOChDirectionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity."
 ::= { optIfOChConfigEntry 1 }
optIfOChCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 losP(0),
 los(1),
 oci(2),
 ssfP(3),
 ssfO(4),
 ssf(5)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 This object is applicable when optIfOChDirectionality
 has the value sink(1) or bidirectional(3).
 In full-capability systems the bit position los(1) is not used.
 In reduced-capability systems or at IrDI interfaces only
 the bit positions los(1) and ssfP(3) are used."
 ::= { optIfOChConfigEntry 2 }
-- OCh sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChSinkCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh sink performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOCh 2 }
optIfOChSinkCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOChSinkCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh sink performance
 monitoring information for an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOChSinkCurrentTable 1 }
OptIfOChSinkCurrentEntry ::=
 SEQUENCE {
 optIfOChSinkCurrentSuspectedFlag TruthValue,
 optIfOChSinkCurrentInputPower Integer32,
 optIfOChSinkCurrentLowInputPower Integer32,
 optIfOChSinkCurrentHighInputPower Integer32,
 optIfOChSinkCurrentLowerInputPowerThreshold Integer32,
 optIfOChSinkCurrentUpperInputPowerThreshold Integer32
 }
optIfOChSinkCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSinkCurrentEntry 1 }
optIfOChSinkCurrentInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the input."
 ::= { optIfOChSinkCurrentEntry 2 }
optIfOChSinkCurrentLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 current 15-minute interval."
 ::= { optIfOChSinkCurrentEntry 3 }
optIfOChSinkCurrentHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 current 15-minute interval."
 ::= { optIfOChSinkCurrentEntry 4 }
optIfOChSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on input power. If
 optIfOChSinkCurrentInputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChSinkCurrentEntry 5 }
optIfOChSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on input power. If
 optIfOChSinkCurrentInputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChSinkCurrentEntry 6 }
-- OCh sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChSinkIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OCh sink performance monitoring
 information."
 ::= { optIfOCh 3 }
optIfOChSinkIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOChSinkIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh sink performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOChSinkIntervalNumber }
 ::= { optIfOChSinkIntervalTable 1 }
OptIfOChSinkIntervalEntry ::=
 SEQUENCE {
 optIfOChSinkIntervalNumber OptIfIntervalNumber,
 optIfOChSinkIntervalSuspectedFlag TruthValue,
 optIfOChSinkIntervalLastInputPower Integer32,
 optIfOChSinkIntervalLowInputPower Integer32,
 optIfOChSinkIntervalHighInputPower Integer32
 }
optIfOChSinkIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOChSinkIntervalEntry 1 }
optIfOChSinkIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSinkIntervalEntry 2 }
optIfOChSinkIntervalLastInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the input during the
 interval."
 ::= { optIfOChSinkIntervalEntry 3 }
optIfOChSinkIntervalLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 interval."
 ::= { optIfOChSinkIntervalEntry 4 }
optIfOChSinkIntervalHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 interval."
 ::= { optIfOChSinkIntervalEntry 5 }
-- OCh sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChSinkCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh sink performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOCh 4 }
optIfOChSinkCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOChSinkCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh sink performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChSinkCurDayTable 1 }
OptIfOChSinkCurDayEntry ::=
 SEQUENCE {
 optIfOChSinkCurDaySuspectedFlag TruthValue,
 optIfOChSinkCurDayLowInputPower Integer32,
 optIfOChSinkCurDayHighInputPower Integer32
 }
optIfOChSinkCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSinkCurDayEntry 1 }
optIfOChSinkCurDayLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 current 24-hour interval."
 ::= { optIfOChSinkCurDayEntry 2 }
optIfOChSinkCurDayHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 current 24-hour interval."
 ::= { optIfOChSinkCurDayEntry 3 }
-- OCh sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChSinkPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh sink performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOCh 5 }
optIfOChSinkPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOChSinkPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh sink performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChSinkPrevDayTable 1 }
OptIfOChSinkPrevDayEntry ::=
 SEQUENCE {
 optIfOChSinkPrevDaySuspectedFlag TruthValue,
 optIfOChSinkPrevDayLastInputPower Integer32,
 optIfOChSinkPrevDayLowInputPower Integer32,
 optIfOChSinkPrevDayHighInputPower Integer32
 }
optIfOChSinkPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSinkPrevDayEntry 1 }
optIfOChSinkPrevDayLastInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOChSinkPrevDayEntry 2 }
optIfOChSinkPrevDayLowInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOChSinkPrevDayEntry 3 }
optIfOChSinkPrevDayHighInputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the input during the
 previous 24-hour interval."
 ::= { optIfOChSinkPrevDayEntry 4 }
-- OCh source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChSrcCurrentTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh source performance monitoring information for
 the current 15-minute interval."
 ::= { optIfOCh 6 }
optIfOChSrcCurrentEntry OBJECT-TYPE
 SYNTAX OptIfOChSrcCurrentEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh source performance
 monitoring information of an interface for the current
 15-minute interval."
 INDEX { ifIndex }
 ::= { optIfOChSrcCurrentTable 1 }
OptIfOChSrcCurrentEntry ::=
 SEQUENCE {
 optIfOChSrcCurrentSuspectedFlag TruthValue,
 optIfOChSrcCurrentOutputPower Integer32,
 optIfOChSrcCurrentLowOutputPower Integer32,
 optIfOChSrcCurrentHighOutputPower Integer32,
 optIfOChSrcCurrentLowerOutputPowerThreshold Integer32,
 optIfOChSrcCurrentUpperOutputPowerThreshold Integer32
 }
optIfOChSrcCurrentSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSrcCurrentEntry 1 }
optIfOChSrcCurrentOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The optical power monitored at the output."
 ::= { optIfOChSrcCurrentEntry 2 }
optIfOChSrcCurrentLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOChSrcCurrentEntry 3 }
optIfOChSrcCurrentHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 15-minute interval."
 ::= { optIfOChSrcCurrentEntry 4 }
optIfOChSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The lower limit threshold on output power. If
 optIfOChSrcCurrentOutputPower drops to this value or below,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChSrcCurrentEntry 5 }
optIfOChSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The upper limit threshold on output power. If
 optIfOChSrcCurrentOutputPower reaches or exceeds this value,
 a Threshold Crossing Alert (TCA) should be sent."
 ::= { optIfOChSrcCurrentEntry 6 }
-- OCh source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChSrcIntervalTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of historical OCh source performance monitoring
 information."
 ::= { optIfOCh 7 }
optIfOChSrcIntervalEntry OBJECT-TYPE
 SYNTAX OptIfOChSrcIntervalEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh source performance
 monitoring information of an interface during a particular
 historical interval."
 INDEX { ifIndex, optIfOChSrcIntervalNumber }
 ::= { optIfOChSrcIntervalTable 1 }
OptIfOChSrcIntervalEntry ::=
 SEQUENCE {
 optIfOChSrcIntervalNumber OptIfIntervalNumber,
 optIfOChSrcIntervalSuspectedFlag TruthValue,
 optIfOChSrcIntervalLastOutputPower Integer32,
 optIfOChSrcIntervalLowOutputPower Integer32,
 optIfOChSrcIntervalHighOutputPower Integer32
 }
optIfOChSrcIntervalNumber OBJECT-TYPE
 SYNTAX OptIfIntervalNumber
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Uniquely identifies the interval."
 ::= { optIfOChSrcIntervalEntry 1 }
optIfOChSrcIntervalSuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSrcIntervalEntry 2 }
optIfOChSrcIntervalLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 interval."
 ::= { optIfOChSrcIntervalEntry 3 }
optIfOChSrcIntervalLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 interval."
 ::= { optIfOChSrcIntervalEntry 4 }
optIfOChSrcIntervalHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 interval."
 ::= { optIfOChSrcIntervalEntry 5 }
-- OCh source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChSrcCurDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh source performance monitoring information for
 the current 24-hour interval."
 ::= { optIfOCh 8 }
optIfOChSrcCurDayEntry OBJECT-TYPE
 SYNTAX OptIfOChSrcCurDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh source performance
 monitoring information of an interface for the current
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChSrcCurDayTable 1 }
OptIfOChSrcCurDayEntry ::=
 SEQUENCE {
 optIfOChSrcCurDaySuspectedFlag TruthValue,
 optIfOChSrcCurDayLowOutputPower Integer32,
 optIfOChSrcCurDayHighOutputPower Integer32
 }
optIfOChSrcCurDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSrcCurDayEntry 1 }
optIfOChSrcCurDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOChSrcCurDayEntry 2 }
optIfOChSrcCurDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 current 24-hour interval."
 ::= { optIfOChSrcCurDayEntry 3 }
-- OCh source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChSrcPrevDayTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOChSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OCh source performance monitoring information for
 the previous 24-hour interval."
 ::= { optIfOCh 9 }
optIfOChSrcPrevDayEntry OBJECT-TYPE
 SYNTAX OptIfOChSrcPrevDayEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OCh source performance
 monitoring information of an interface for the previous
 24-hour interval."
 INDEX { ifIndex }
 ::= { optIfOChSrcPrevDayTable 1 }
OptIfOChSrcPrevDayEntry ::=
 SEQUENCE {
 optIfOChSrcPrevDaySuspectedFlag TruthValue,
 optIfOChSrcPrevDayLastOutputPower Integer32,
 optIfOChSrcPrevDayLowOutputPower Integer32,
 optIfOChSrcPrevDayHighOutputPower Integer32
 }
optIfOChSrcPrevDaySuspectedFlag OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "If true, the data in this entry may be unreliable."
 ::= { optIfOChSrcPrevDayEntry 1 }
optIfOChSrcPrevDayLastOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The last optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOChSrcPrevDayEntry 2 }
optIfOChSrcPrevDayLowOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The lowest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOChSrcPrevDayEntry 3 }
optIfOChSrcPrevDayHighOutputPower OBJECT-TYPE
 SYNTAX Integer32
 UNITS "0.1 dbm"
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The highest optical power monitored at the output during the
 previous 24-hour interval."
 ::= { optIfOChSrcPrevDayEntry 4 }
-- the optIfOTUk group
-- This group handles the configuration
-- information for OTUk layers.
-- OTUk config table
optIfOTUkConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfOTUkConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of OTUk configuration information."
 ::= { optIfOTUk 1 }
optIfOTUkConfigEntry OBJECT-TYPE
 SYNTAX OptIfOTUkConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains OTUk configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfOTUkConfigTable 1 }
OptIfOTUkConfigEntry ::=
 SEQUENCE {
 optIfOTUkDirectionality OptIfDirectionality,
 optIfOTUkBitRateK OptIfBitRateK,
 optIfOTUkTraceIdentifierTransmitted OptIfTxTI,
 optIfOTUkDAPIExpected OptIfExDAPI,
 optIfOTUkSAPIExpected OptIfExSAPI,
 optIfOTUkTraceIdentifierAccepted OptIfAcTI,
 optIfOTUkTIMDetMode OptIfTIMDetMode,
 optIfOTUkTIMActEnabled TruthValue,
 optIfOTUkDEGThr OptIfDEGThr,
 optIfOTUkDEGM OptIfDEGM,
 optIfOTUkSinkAdaptActive TruthValue,
 optIfOTUkSourceAdaptActive TruthValue,
 optIfOTUkSinkFECEnabled TruthValue,
 optIfOTUkCurrentStatus BITS
 }
optIfOTUkDirectionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity."
 ::= { optIfOTUkConfigEntry 1 }
optIfOTUkBitRateK OBJECT-TYPE
 SYNTAX OptIfBitRateK
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the bit rate of the entity."
 ::= { optIfOTUkConfigEntry 2 }
optIfOTUkTraceIdentifierTransmitted OBJECT-TYPE
 SYNTAX OptIfTxTI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The trace identifier transmitted.
 This object is applicable when optIfOTUkDirectionality
 has the value source(2) or bidirectional(3). It must not
 be instantiated in rows where optIfOTUkDirectionality
 has the value sink(1).
 If no value is ever set by a management entity for this
 object, system-specific default value will be used.
 Any implementation that instantiates this object must
 document the system-specific default value or how it
 is derived."
 ::= { optIfOTUkConfigEntry 3 }
optIfOTUkDAPIExpected OBJECT-TYPE
 SYNTAX OptIfExDAPI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The DAPI expected by the receiver.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 This object has no effect when optIfOTUkTIMDetMode has
 the value off(1)."
 ::= { optIfOTUkConfigEntry 4 }
optIfOTUkSAPIExpected OBJECT-TYPE
 SYNTAX OptIfExSAPI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The SAPI expected by the receiver.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 This object has no effect when optIfOTUkTIMDetMode has
 the value off(1)."
 ::= { optIfOTUkConfigEntry 5 }
optIfOTUkTraceIdentifierAccepted OBJECT-TYPE
 SYNTAX OptIfAcTI
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The actual trace identifier accepted.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 The value of this object is unspecified when
 optIfOTUkCurrentStatus indicates a near-end defect
 (i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents
 extraction of the trace message."
 ::= { optIfOTUkConfigEntry 6 }
optIfOTUkTIMDetMode OBJECT-TYPE
 SYNTAX OptIfTIMDetMode
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 The default value of this object is off(1)."
 ::= { optIfOTUkConfigEntry 7 }
optIfOTUkTIMActEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates whether the Trace Identifier Mismatch (TIM)
 Consequent Action function is enabled.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 This object has no effect when optIfOTUkTIMDetMode has
 the value off(1).
 The default value of this object is false(2)."
 ::= { optIfOTUkConfigEntry 8 }
optIfOTUkDEGThr OBJECT-TYPE
 SYNTAX OptIfDEGThr
 UNITS "percentage"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a performance
 monitoring (PM) Second to be bad. A PM Second is declared bad if
 the percentage of detected errored blocks in that second is
 greater than or equal to optIfOTUkDEGThr.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 The default value of this object is Severely Errored Second
 (SES) Estimator (See ITU-T G.7710)."
 ::= { optIfOTUkConfigEntry 9 }
optIfOTUkDEGM OBJECT-TYPE
 SYNTAX OptIfDEGM
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a Degraded Signal
 defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM
 consecutive bad PM Seconds are detected.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 The default value of this object is 7 (See ITU-T G.7710)."
 ::= { optIfOTUkConfigEntry 10 }
optIfOTUkSinkAdaptActive OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates whether the sink adaptation function is activated or
 not.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 The default value of this object is false(2)."
 ::= { optIfOTUkConfigEntry 11 }
optIfOTUkSourceAdaptActive OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates whether the source adaptation function is activated or
 not.
 This object is only applicable to the source function, i.e.,
 only when optIfOTUkDirectionality has the value source(2)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value sink(1).
 The default value of this object is false(2)."
 ::= { optIfOTUkConfigEntry 12 }
optIfOTUkSinkFECEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "If Forward Error Correction (FEC) is supported, this object
 indicates whether FEC at the OTUk sink adaptation function is
 enabled or not.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2).
 The default value of this object is true(1)."
 ::= { optIfOTUkConfigEntry 13 }
optIfOTUkCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 tim(0),
 deg(1),
 bdi(2),
 ssf(3),
 lof(4),
 ais(5),
 lom(6)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 This object is only applicable to the sink function, i.e.,
 only when optIfOTUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfOTUkDirectionality has the value source(2)."
 ::= { optIfOTUkConfigEntry 14 }
-- GCC0 config table
optIfGCC0ConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfGCC0ConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of GCC0 configuration information."
 ::= { optIfOTUk 2 }
optIfGCC0ConfigEntry OBJECT-TYPE
 SYNTAX OptIfGCC0ConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains GCC0 configuration
 information of an interface. Each instance must
 correspond to an instance of optIfOTUkConfigEntry.
 Separate source and/or sink instances may exist
 for a given ifIndex value, or a single bidirectional
 instance may exist, but a bidirectional instance may
 not coexist with a source or sink instance.
 Instances of this conceptual row persist across
 agent restarts."
 INDEX { ifIndex, optIfGCC0Directionality }
 ::= { optIfGCC0ConfigTable 1 }
OptIfGCC0ConfigEntry ::=
 SEQUENCE {
 optIfGCC0Directionality OptIfDirectionality,
 optIfGCC0Application SnmpAdminString,
 optIfGCC0RowStatus RowStatus
 }
optIfGCC0Directionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity.
 The values source(2) and bidirectional(3) are
 not allowed if the corresponding instance of
 optIfOTUkDirectionality has the value sink(1).
 The values sink(1) and bidirectional(3) are
 not allowed if the corresponding instance of
 optIfOTUkDirectionality has the value source(2)."
 ::= { optIfGCC0ConfigEntry 1 }
optIfGCC0Application OBJECT-TYPE
 SYNTAX SnmpAdminString
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the application transported by the GCC0 entity.
 Example applications are ECC, User data channel.
 The value of this object may not be changed when
 optIfGCC0RowStatus has the value active(1)."
 ::= { optIfGCC0ConfigEntry 2 }
optIfGCC0RowStatus OBJECT-TYPE
 SYNTAX RowStatus
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "This columnar object is used for creating and deleting a
 conceptual row of the optIfGCC0 config table.
 It is used to model the addGCC0Access and removeGCC0Access
 operations of an OTUk_TTP for GCC0 access control as defined
 in G.874.1. Setting RowStatus to createAndGo or createAndWait
 implies addGCC0Access. Setting RowStatus to destroy implies
 removeGCC0Access."
 ::= { optIfGCC0ConfigEntry 3 }
-- the optIfODUk group
-- This group handles the configuration information
-- for the ODUk layers.
-- ODUk config table
optIfODUkConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfODUkConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of ODUk configuration information."
 ::= { optIfODUk 1 }
optIfODUkConfigEntry OBJECT-TYPE
 SYNTAX OptIfODUkConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains ODUk configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfODUkConfigTable 1 }
OptIfODUkConfigEntry ::=
 SEQUENCE {
 optIfODUkDirectionality OptIfDirectionality,
 optIfODUkBitRateK OptIfBitRateK,
 optIfODUkTcmFieldsInUse BITS,
 optIfODUkPositionSeqCurrentSize Unsigned32,
 optIfODUkTtpPresent TruthValue
 }
optIfODUkDirectionality OBJECT-TYPE
 SYNTAX OptIfDirectionality
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the entity."
 ::= { optIfODUkConfigEntry 1 }
optIfODUkBitRateK OBJECT-TYPE
 SYNTAX OptIfBitRateK
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the bit rate of the entity."
 ::= { optIfODUkConfigEntry 2 }
optIfODUkTcmFieldsInUse OBJECT-TYPE
 SYNTAX BITS {
 tcmField1(0),
 tcmField2(1),
 tcmField3(2),
 tcmField4(3),
 tcmField5(4),
 tcmField6(5)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the TCM field(s) that are currently in use.
 The positions of the bits correspond to the TCM fields.
 A bit that is set to 1 means that the corresponding TCM
 field is used. This object will be updated when rows are
 created in or deleted from the optIfODUkTConfigTable, or
 the optIfODUkTNimConfigTable."
 ::= { optIfODUkConfigEntry 3 }
optIfODUkPositionSeqCurrentSize OBJECT-TYPE
 SYNTAX Unsigned32
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This variable indicates the current size of the position
 sequence (i.e., number of TCM function and/or GCC12
 access that have been created in the ODUk interface).
 When the value of this variable is greater than zero,
 it means that one or more TCM function and/or GCC12
 access have been created in the ODUk interface. In this
 case, there will be as many rows in the
 optIfODUkPositionSeqTable as the value of
 optIfODUkPositionSeqCurrentSize corresponding to this
 ODUk interface, one row for each TCM function or GCC12
 access. The position of the TCM function and/or
 GCC12 access within the sequence is indicated by the
 optIfODUkPositionSeqPosition variable in
 optIfODUkPositionSeqTable.
 The optIfODUkPositionSeqTable also provides pointers
 to the corresponding TCM function (optIfODUkT) and
 GCC12 access (optIfGCC12) entities."
 ::= { optIfODUkConfigEntry 4 }
optIfODUkTtpPresent OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This object has the value true(1) if the ifEntry under which
 it is instantiated contains an ODUk Trail Termination Point,
 i.e., is the endpoint of an ODUk path. In that case there
 will be a corresponding row in the ODUk TTP config table and
 it will not be possible to create corresponding rows in the
 ODUk NIM config table. This object has the value false(2)
 if the ifEntry under which it is instantiated contains an
 intermediate ODUk Connection Termination Point. In that case
 there is no corresponding row in the ODUk TTP config table,
 but it will be possible to create corresponding rows in the
 ODUk NIM config table. This object also affects the allowable
 options in rows created in the GCC12 config table and in the
 ODUkT config table, as specified in the DESCRIPTION clauses
 of the columns in those tables."
 ::= { optIfODUkConfigEntry 5 }
-- ODUk Trail Termination Point (TTP) config table
optIfODUkTtpConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfODUkTtpConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of ODUk TTP configuration information."
 ::= { optIfODUk 2 }
optIfODUkTtpConfigEntry OBJECT-TYPE
 SYNTAX OptIfODUkTtpConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains ODUk TTP configuration
 information of an interface."
 INDEX { ifIndex }
 ::= { optIfODUkTtpConfigTable 1 }
OptIfODUkTtpConfigEntry ::=
 SEQUENCE {
 optIfODUkTtpTraceIdentifierTransmitted OptIfTxTI,
 optIfODUkTtpDAPIExpected OptIfExDAPI,
 optIfODUkTtpSAPIExpected OptIfExSAPI,
 optIfODUkTtpTraceIdentifierAccepted OptIfAcTI,
 optIfODUkTtpTIMDetMode OptIfTIMDetMode,
 optIfODUkTtpTIMActEnabled TruthValue,
 optIfODUkTtpDEGThr OptIfDEGThr,
 optIfODUkTtpDEGM OptIfDEGM,
 optIfODUkTtpCurrentStatus BITS
 }
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE
 SYNTAX OptIfTxTI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The trace identifier transmitted.
 This object is applicable when optIfODUkDirectionality
 has the value source(2) or bidirectional(3). It must not
 be instantiated in rows where optIfODUkDirectionality
 has the value sink(1).
 If no value is ever set by a management entity for this
 object, system-specific default value will be used.
 Any implementation that instantiates this object must
 document the system-specific default value or how it
 is derived."
 ::= { optIfODUkTtpConfigEntry 1 }
optIfODUkTtpDAPIExpected OBJECT-TYPE
 SYNTAX OptIfExDAPI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The DAPI expected by the receiver.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 This object has no effect when optIfODUkTtpTIMDetMode has
 the value off(1)."
 ::= { optIfODUkTtpConfigEntry 2 }
optIfODUkTtpSAPIExpected OBJECT-TYPE
 SYNTAX OptIfExSAPI
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "The SAPI expected by the receiver.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 This object has no effect when optIfODUkTtpTIMDetMode has
 the value off(1)."
 ::= { optIfODUkTtpConfigEntry 3 }
optIfODUkTtpTraceIdentifierAccepted OBJECT-TYPE
 SYNTAX OptIfAcTI
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The actual trace identifier accepted.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 The value of this object is unspecified when
 optIfODUkTtpCurrentStatus indicates a near-end defect
 (i.e., oci(0), lck(1), ssf(5)) that prevents extraction
 of the trace message."
 ::= { optIfODUkTtpConfigEntry 4 }
optIfODUkTtpTIMDetMode OBJECT-TYPE
 SYNTAX OptIfTIMDetMode
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 The default value of this object is off(1)."
 ::= { optIfODUkTtpConfigEntry 5 }
optIfODUkTtpTIMActEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates whether the Trace Identifier Mismatch (TIM)
 Consequent Action function is enabled.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 This object has no effect when optIfODUkTtpTIMDetMode has
 the value off(1).
 The default value of this object is false(2)."
 ::= { optIfODUkTtpConfigEntry 6 }
optIfODUkTtpDEGThr OBJECT-TYPE
 SYNTAX OptIfDEGThr
 UNITS "percentage"
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a performance
 monitoring (PM) Second to be bad. A PM Second is declared bad if
 the percentage of detected errored blocks in that second is
 greater than or equal to optIfODUkDEGThr.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 The default value of this object is Severely Errored Second
 (SES) Estimator (See ITU-T G.7710)."
 ::= { optIfODUkTtpConfigEntry 7 }
optIfODUkTtpDEGM OBJECT-TYPE
 SYNTAX OptIfDEGM
 MAX-ACCESS read-write
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a Degraded Signal
 defect (dDEG). A dDEG shall be declared if optIfODUkDEGM
 consecutive bad PM Seconds are detected.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2).
 The default value of this object is 7 (See ITU-T G.7710)."
 ::= { optIfODUkTtpConfigEntry 8 }
optIfODUkTtpCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 oci(0),
 lck(1),
 tim(2),
 deg(3),
 bdi(4),
 ssf(5)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 This object is only applicable to the sink function, i.e.,
 only when optIfODUkDirectionality has the value sink(1)
 or bidirectional(3). It must not be instantiated in rows
 where optIfODUkDirectionality has the value source(2)."
 ::= { optIfODUkTtpConfigEntry 9 }
-- ODUk Position Sequence table
optIfODUkPositionSeqTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfODUkPositionSeqEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of ODUk Position Sequence information."
 ::= { optIfODUk 3 }
optIfODUkPositionSeqEntry OBJECT-TYPE
 SYNTAX OptIfODUkPositionSeqEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains ODUk position sequence
 information of an ODUk interface. The ODUk interface
 is identified by the ifIndex. Associated with each
 ODUk interface there may be one of more conceptual
 rows in the optIfODUkPositionSeqTable. Each row
 represents a TCM or GCC12 access function within the
 associated ODUk interface. Rows of the
 optIfODUkPositionSeqTable table are created/deleted
 as the result of the creation/deletion of the optIfODUkT
 or optIfGCC12 entities."
 INDEX { ifIndex, optIfODUkPositionSeqIndex }
 ::= { optIfODUkPositionSeqTable 1 }
OptIfODUkPositionSeqEntry ::=
 SEQUENCE {
 optIfODUkPositionSeqIndex Unsigned32,
 optIfODUkPositionSeqPosition Unsigned32,
 optIfODUkPositionSeqPointer RowPointer
 }
optIfODUkPositionSeqIndex OBJECT-TYPE
 SYNTAX Unsigned32 (1..4294967295)
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "This variable identifies a row in the
 optIfODUkPositionSeqTable Table.
 Each row of the optIfODUkPositionSeqTable Table
 represents a TCM or GCC12 access function within the
 associated ODUk interface."
 ::= { optIfODUkPositionSeqEntry 1 }
optIfODUkPositionSeqPosition OBJECT-TYPE
 SYNTAX Unsigned32
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This variable indicates the position of the TCM or
 GCC12 access function within the sequence of TCMs &
 GCC12 access functions of the associated ODUk
 interface. The TCM or GCC12 presented by this row is
 referenced by the optIfODUkPositionSeqPointer variable."
 ::= { optIfODUkPositionSeqEntry 2 }
optIfODUkPositionSeqPointer OBJECT-TYPE
 SYNTAX RowPointer
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "This variable identifies the TCM or GCC12 access function
 by pointing to the corresponding optIfODUkT or optIfGCC12
 entity."
 ::= { optIfODUkPositionSeqEntry 3 }
-- ODUk Non-intrusive monitoring (Nim) config table
optIfODUkNimConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfODUkNimConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of ODUkNim configuration information."
 ::= { optIfODUk 4 }
optIfODUkNimConfigEntry OBJECT-TYPE
 SYNTAX OptIfODUkNimConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains ODUkNim configuration
 information of an interface. Each instance must
 correspond to an instance of optIfODUkConfigEntry
 for which optIfODUkTtpPresent has the value false(2).
 Instances of this conceptual row persist across
 agent restarts, and read-create columns other
 than the status column may be modified while the
 row is active."
 INDEX { ifIndex, optIfODUkNimDirectionality }
 ::= { optIfODUkNimConfigTable 1 }
OptIfODUkNimConfigEntry ::=
 SEQUENCE {
 optIfODUkNimDirectionality OptIfSinkOrSource,
 optIfODUkNimDAPIExpected OptIfExDAPI,
 optIfODUkNimSAPIExpected OptIfExSAPI,
 optIfODUkNimTraceIdentifierAccepted OptIfAcTI,
 optIfODUkNimTIMDetMode OptIfTIMDetMode,
 optIfODUkNimTIMActEnabled TruthValue,
 optIfODUkNimDEGThr OptIfDEGThr,
 optIfODUkNimDEGM OptIfDEGM,
 optIfODUkNimCurrentStatus BITS,
 optIfODUkNimRowStatus RowStatus
 }
optIfODUkNimDirectionality OBJECT-TYPE
 SYNTAX OptIfSinkOrSource
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Specifies the monitor point for the ODUk Path non-intrusive
 monitoring function. The value source(2) is not allowed
 if the corresponding instance of optIfODUkDirectionality
 has the value sink(1), and the value sink(1) is not allowed
 if the corresponding instance of optIfODUkDirectionality
 has the value source(2). Either the value sink(1) or
 source(2) is allowed if the corresponding instance of
 optIfODUkDirectionality has the value bidirectional(3).
 The value sink(1) means monitoring at the sink direction
 path signal of the ODUk CTP.
 The value source(2) means monitoring at the source direction
 path signal of the ODUk CTP. Monitoring the source direction
 of an ODUk CTP is necessary in those cases where the ODUk CTP
 is at an SNCP (Subnetwork Connection Protection) end (e.g., see
 Figure I.1.2/G.874.1). If one would like to get the performance
 of the protected connection, one cannot use the NIM function
 at both ODUk CTP sinks (before the matrix), instead one should
 monitor the signal at the source ODUk CTP after the matrix."
 ::= { optIfODUkNimConfigEntry 1 }
optIfODUkNimDAPIExpected OBJECT-TYPE
 SYNTAX OptIfExDAPI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The DAPI expected by the receiver.
 This object has no effect if optIfODUkNimTIMDetMode has
 the value off(1) or sapi(3)."
 ::= { optIfODUkNimConfigEntry 2 }
optIfODUkNimSAPIExpected OBJECT-TYPE
 SYNTAX OptIfExSAPI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The SAPI expected by the receiver.
 This object has no effect if optIfODUkNimTIMDetMode has
 the value off(1) or dapi(2)."
 ::= { optIfODUkNimConfigEntry 3 }
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE
 SYNTAX OptIfAcTI
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The actual trace identifier accepted. The value of
 this object is unspecified if optIfODUkNimCurrentStatus
 has any of the bit positions oci(0), lck(1), or ssf(5)
 set or if optIfODUkNimRowStatus has any value other
 than active(1)."
 ::= { optIfODUkNimConfigEntry 4 }
optIfODUkNimTIMDetMode OBJECT-TYPE
 SYNTAX OptIfTIMDetMode
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function."
 ::= { optIfODUkNimConfigEntry 5 }
optIfODUkNimTIMActEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates whether the Trace Identifier Mismatch (TIM)
 Consequent Action function is enabled."
 ::= { optIfODUkNimConfigEntry 6 }
optIfODUkNimDEGThr OBJECT-TYPE
 SYNTAX OptIfDEGThr
 UNITS "percentage"
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a performance
 monitoring (PM) Second to be bad. A PM Second is declared bad
 if the percentage of detected errored blocks in that second is
 greater than or equal to optIfODUkNimDEGThr."
 ::= { optIfODUkNimConfigEntry 7 }
optIfODUkNimDEGM OBJECT-TYPE
 SYNTAX OptIfDEGM
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a Degraded Signal
 defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM
 consecutive bad PM Seconds are detected."
 ::= { optIfODUkNimConfigEntry 8 }
optIfODUkNimCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 oci(0),
 lck(1),
 tim(2),
 deg(3),
 bdi(4),
 ssf(5)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if
 any. The value of this object is unspecified if
 optIfODUkNimRowStatus has any value other than
 active(1)."
 ::= { optIfODUkNimConfigEntry 9 }
optIfODUkNimRowStatus OBJECT-TYPE
 SYNTAX RowStatus
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "This columnar object is used for creating and deleting
 a conceptual row of the optIfODUkNim config table.
 It is used to model the activateNim and deactivateNim
 operations of an OTUk_CTP for non-intrusive monitoring
 control as defined in G.874.1. Setting RowStatus to
 createAndGo or createAndWait implies activateNim.
 Setting RowStatus to destroy implies deactivateNim."
 ::= { optIfODUkNimConfigEntry 10 }
-- GCC12 config table
optIfGCC12ConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfGCC12ConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of GCC12 configuration information.
 The GCC function processes the GCC overhead bytes passing
 through them but leave the remainder of the ODUk overhead
 and payload data alone."
 ::= { optIfODUk 5 }
optIfGCC12ConfigEntry OBJECT-TYPE
 SYNTAX OptIfGCC12ConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains GCC12 configuration
 information of an interface. Each instance must
 correspond to an instance of optIfODUkConfigEntry.
 Separate instances providing GCC1-only access and
 GCC2-only access may exist for a given ifIndex value,
 or a single instance providing GCC1 + GCC2 may exist,
 but a GCC1 + GCC2 instance may not coexist with a
 GCC1-only or GCC2-only instance.
 Instances of this conceptual row persist across agent
 restarts."
 INDEX { ifIndex, optIfGCC12Codirectional, optIfGCC12GCCAccess }
 ::= { optIfGCC12ConfigTable 1 }
OptIfGCC12ConfigEntry ::=
 SEQUENCE {
 optIfGCC12Codirectional TruthValue,
 optIfGCC12GCCAccess INTEGER,
 optIfGCC12GCCPassThrough TruthValue,
 optIfGCC12Application SnmpAdminString,
 optIfGCC12RowStatus RowStatus
 }
optIfGCC12Codirectional OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the GCC12 termination with
 respect to the associated ODUk CTP. The value true(1) means
 that the sink part of the GCC12 extracts COMMS data from the
 signal at the input to the ODUk CTP sink and the source part
 of the GCC12 inserts COMMS data into the signal at the output
 of the ODUk CTP source. The value false(2) means that the
 sink part of the GCC12 extracts COMMS data from the signal at
 the output of the ODUk CTP source and the source part of the
 GCC12 inserts COMMS data into the signal at the input of the
 ODUk CTP sink. This attribute may assume either value when
 the corresponding instance of optIfODUkTtpPresent has the
 value false(2). When the value of the corresponding instance
 of optIfODUkTtpPresent is true(1) then the only value allowed
 for this attribute is true(1)."
 ::= { optIfGCC12ConfigEntry 1 }
optIfGCC12GCCAccess OBJECT-TYPE
 SYNTAX INTEGER {
 gcc1 (1),
 gcc2 (2),
 gcc1and2 (3)
 }
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Indicates the GCC access represented by the entity."
 ::= { optIfGCC12ConfigEntry 2 }
optIfGCC12GCCPassThrough OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Controls whether the selected GCC overhead bytes are passed
 through or modified. The value true(1) means that the selected
 GCC overhead bytes are passed through unmodified from the ODUk
 CTP input to the ODUk CTP output. The value false(2) means that
 the selected GCC overhead bytes are set to zero at the ODUk CTP
 output after the extraction of the COMMS data. This object has
 no effect if the corresponding instance of optIfODUkTtpPresent
 has the value true(1).
 The value of this object may not be changed when
 optIfGCC12RowStatus has the value active(1)."
 ::= { optIfGCC12ConfigEntry 3 }
optIfGCC12Application OBJECT-TYPE
 SYNTAX SnmpAdminString
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the application transported by the GCC12 entity.
 Example applications are ECC, User data channel.
 The value of this object may not be changed when
 optIfGCC12RowStatus has the value active(1)."
 ::= { optIfGCC12ConfigEntry 4 }
optIfGCC12RowStatus OBJECT-TYPE
 SYNTAX RowStatus
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "This columnar object is used for creating and deleting
 a conceptual row of the optIfGCC12 config table. It is
 used to model the addGCC12Access and removeGCC12Access
 operations of an ODUk_CTP or ODUk_TTP for GCC12 access
 control as defined in G.874.1. Setting RowStatus to
 createAndGo or createAndWait implies addGCC12Access.
 Setting RowStatus to destroy implies removeGCC12Access.
 Successful addition/removal of the GCC12 access function
 will result in updating the
 optIfODUkPositionSeqCurrentSize variable and the
 optIfODUkPositionSeqTable table of the associated
 ODUk entry in the optIfODUkConfigTable."
 ::= { optIfGCC12ConfigEntry 5 }
-- the optIfODUkT group
-- This group handles the configuration information
-- for the ODUkT layers.
-- ODUkT config table
optIfODUkTConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfODUkTConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of ODUkT configuration information."
 ::= { optIfODUkT 1 }
optIfODUkTConfigEntry OBJECT-TYPE
 SYNTAX OptIfODUkTConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains ODUkT configuration
 information of an interface. Each instance must
 correspond to an instance of optIfODUkConfigEntry.
 Rows in this table are mutually exclusive with rows
 in the ODUkT NIM config table -- in other words, this
 row object may not be instantiated for a given pair
 of ifIndex and TCM field values if a corresponding
 instance of optIfODUkTNimConfigEntry already exists.
 Instances of this conceptual row persist across agent
 restarts. Except where noted otherwise, read-create
 columns other than the status column may be modified
 while the row is active."
 INDEX { ifIndex, optIfODUkTTcmField, optIfODUkTCodirectional }
 ::= { optIfODUkTConfigTable 1 }
OptIfODUkTConfigEntry ::=
 SEQUENCE {
 optIfODUkTTcmField Unsigned32,
 optIfODUkTCodirectional TruthValue,
 optIfODUkTTraceIdentifierTransmitted OptIfTxTI,
 optIfODUkTDAPIExpected OptIfExDAPI,
 optIfODUkTSAPIExpected OptIfExSAPI,
 optIfODUkTTraceIdentifierAccepted OptIfAcTI,
 optIfODUkTTIMDetMode OptIfTIMDetMode,
 optIfODUkTTIMActEnabled TruthValue,
 optIfODUkTDEGThr OptIfDEGThr,
 optIfODUkTDEGM OptIfDEGM,
 optIfODUkTSinkMode INTEGER,
 optIfODUkTSinkLockSignalAdminState INTEGER,
 optIfODUkTSourceLockSignalAdminState INTEGER,
 optIfODUkTCurrentStatus BITS,
 optIfODUkTRowStatus RowStatus
 }
optIfODUkTTcmField OBJECT-TYPE
 SYNTAX Unsigned32 (1..6)
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Indicates the tandem connection monitoring
 field of the ODUk OH. Valid values are
 integers from 1 to 6."
 ::= { optIfODUkTConfigEntry 1 }
optIfODUkTCodirectional OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Indicates the directionality of the ODUkT termination point with
 respect to the associated ODUk CTP. The value true(1) means
 that the sink part of the ODUkT TP extracts TCM data from the
 signal at the input to the ODUk CTP sink and the source part
 of the ODUkT TP inserts TCM data into the signal at the output
 of the ODUk CTP source. The value false(2) means that the
 sink part of the ODUkT TP extracts TCM data from the signal at
 the output of the ODUk CTP source and the source part of the
 ODUkT TP inserts TCM data into the signal at the input of the
 ODUk CTP sink. This attribute may assume either value when
 the corresponding instance of optIfODUkTtpPresent has the
 value false(2). When the value of the corresponding instance
 of optIfODUkTtpPresent is true(1) then the only value allowed
 for this attribute is true(1)."
 ::= { optIfODUkTConfigEntry 2 }
optIfODUkTTraceIdentifierTransmitted OBJECT-TYPE
 SYNTAX OptIfTxTI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The trace identifier transmitted.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value false(2), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value true(1).
 It must not be instantiated in rows for all other cases."
 ::= { optIfODUkTConfigEntry 3 }
optIfODUkTDAPIExpected OBJECT-TYPE
 SYNTAX OptIfExDAPI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The DAPI expected by the receiver.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 This object has no effect when optIfODUkTTIMDetMode has
 the value off(1)."
 ::= { optIfODUkTConfigEntry 4 }
optIfODUkTSAPIExpected OBJECT-TYPE
 SYNTAX OptIfExSAPI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The SAPI expected by the receiver.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 This object has no effect when optIfODUkTTIMDetMode has
 the value off(1)."
 ::= { optIfODUkTConfigEntry 5 }
optIfODUkTTraceIdentifierAccepted OBJECT-TYPE
 SYNTAX OptIfAcTI
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The actual trace identifier accepted.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 The value of this object is unspecified when
 optIfODUkTCurrentStatus indicates a near-end defect
 (i.e., oci(0), lck(1), ssf(5)) that prevents extraction
 of the trace message."
 ::= { optIfODUkTConfigEntry 6 }
optIfODUkTTIMDetMode OBJECT-TYPE
 SYNTAX OptIfTIMDetMode
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 The default value of this object is off(1)."
 ::= { optIfODUkTConfigEntry 7 }
optIfODUkTTIMActEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates whether the Trace Identifier Mismatch (TIM)
 Consequent Action function is enabled.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 This object has no effect when optIfODUkTTIMDetMode has
 the value off(1).
 The default value of this object is false(2)."
 ::= { optIfODUkTConfigEntry 8 }
optIfODUkTDEGThr OBJECT-TYPE
 SYNTAX OptIfDEGThr
 UNITS "percentage"
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a performance
 monitoring (PM) Second to be bad. A PM Second is declared bad if
 the percentage of detected errored blocks in that second is
 greater than or equal to optIfODUkTDEGThr.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 The default value of this object is Severely Errored Second
 (SES) Estimator (See ITU-T G.7710)."
 ::= { optIfODUkTConfigEntry 9 }
optIfODUkTDEGM OBJECT-TYPE
 SYNTAX OptIfDEGM
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a Degraded Signal
 defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM
 consecutive bad PM Seconds are detected.
 This object is applicable only to the following three cases.
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases.
 The default value of this object is 7 (See ITU-T G.7710)."
 ::= { optIfODUkTConfigEntry 10 }
optIfODUkTSinkMode OBJECT-TYPE
 SYNTAX INTEGER {
 operational (1),
 monitor (2)
 }
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "This variable specifies the TCM mode at the entity.
 The value operational(1) means that TCM Overhead (TCMOH)
 processes (see ITU-T G.798) shall be
 performed and consequent actions for AIS, Trail
 Signal Fail (TSF), Trail Signal Degraded (TSD) shall be
 initiated in case of defects.
 The value monitor(2) means that TCMOH processes shall be
 performed but consequent actions for AIS, Trail
 Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be
 initiated in case of defects.
 This object is applicable only when the value of
 optIfODUkTtpPresent is false(2) and also either one of the
 following three cases holds:
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases."
 ::= { optIfODUkTConfigEntry 11 }
optIfODUkTSinkLockSignalAdminState OBJECT-TYPE
 SYNTAX INTEGER {
 locked(1),
 normal(2)
 }
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Provides the capability to provision the LOCK signal, which
 is one of the ODUk maintenance signals, at the ODUKT sink. When
 a Tandem Connection endpoint is set to admin state locked,
 it inserts the ODUk-LCK signal in the sink direction.
 This object is applicable only when the value of
 optIfODUkTtpPresent is false(2) and also either one of the
 following three cases holds:
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases."
 ::= { optIfODUkTConfigEntry 12 }
optIfODUkTSourceLockSignalAdminState OBJECT-TYPE
 SYNTAX INTEGER {
 locked(1),
 normal(2)
 }
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Provides the capability to provision the LOCK signal, which
 is one of the ODUk maintenance signals, at the source.
 When a Tandem Connection endpoint is set to admin state
 locked, it inserts the ODUk-LCK signal in the source
 direction.
 This object is applicable only when either one of the
 following three cases holds:
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value false(2), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value true(1).
 It must not be instantiated in rows for all other cases."
 ::= { optIfODUkTConfigEntry 13 }
optIfODUkTCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 oci(0),
 lck(1),
 tim(2),
 deg(3),
 bdi(4),
 ssf(5)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 This object is applicable only when either one of the
 following three cases holds:
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It must not be instantiated in rows for all other cases."
 ::= { optIfODUkTConfigEntry 14 }
optIfODUkTRowStatus OBJECT-TYPE
 SYNTAX RowStatus
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "This columnar object is used for creating and deleting a
 conceptual row of the optIfODUkT config table.
 It is used to model the addTCM and removeTCM operations of an
 ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined
 in ITU-T G.874.1.
 Setting RowStatus to createAndGo or createAndWait implies addTCM.
 Setting RowStatus to destroy implies removeTCM.
 Successful addition/removal of TCM will result in updating the
 optIfODUkTcmFieldsInUse and optIfODUkPositionSeqCurrentSize
 variables and the optIfODUkPositionSeqTable table of the
 associated ODUk entry in the optIfODUkConfigTable."
 ::= { optIfODUkTConfigEntry 15 }
-- ODUkT Non-intrusive monitoring (Nim) config table
optIfODUkTNimConfigTable OBJECT-TYPE
 SYNTAX SEQUENCE OF OptIfODUkTNimConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A table of ODUkTNim configuration information."
 ::= { optIfODUkT 2 }
optIfODUkTNimConfigEntry OBJECT-TYPE
 SYNTAX OptIfODUkTNimConfigEntry
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "A conceptual row that contains ODUkTNim configuration
 information of an interface. Each instance must
 correspond to an instance of optIfODUkConfigEntry.
 Rows in this table are mutually exclusive with rows
 in the ODUkT config table -- in other words, this
 row object may not be instantiated for a given pair
 of ifIndex and TCM field values if a corresponding
 instance of optIfODUkTConfigEntry already exists.
 Instances of this conceptual row persist across
 agent restarts, and read-create columns other
 than the status column may be modified while the
 row is active."
 INDEX {ifIndex, optIfODUkTNimTcmField, optIfODUkTNimDirectionality}
 ::= { optIfODUkTNimConfigTable 1 }
OptIfODUkTNimConfigEntry ::=
 SEQUENCE {
 optIfODUkTNimTcmField Unsigned32,
 optIfODUkTNimDirectionality OptIfSinkOrSource,
 optIfODUkTNimDAPIExpected OptIfExDAPI,
 optIfODUkTNimSAPIExpected OptIfExSAPI,
 optIfODUkTNimTraceIdentifierAccepted OptIfAcTI,
 optIfODUkTNimTIMDetMode OptIfTIMDetMode,
 optIfODUkTNimTIMActEnabled TruthValue,
 optIfODUkTNimDEGThr OptIfDEGThr,
 optIfODUkTNimDEGM OptIfDEGM,
 optIfODUkTNimCurrentStatus BITS,
 optIfODUkTNimRowStatus RowStatus
 }
optIfODUkTNimTcmField OBJECT-TYPE
 SYNTAX Unsigned32 (1..6)
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Indicates the tandem connection monitoring
 field of the ODUk OH on which non-intrusive monitoring
 is performed. Valid values are
 integers from 1 to 6."
 ::= { optIfODUkTNimConfigEntry 1 }
optIfODUkTNimDirectionality OBJECT-TYPE
 SYNTAX OptIfSinkOrSource
 MAX-ACCESS not-accessible
 STATUS current
 DESCRIPTION
 "Specifies the monitor point for the ODUk TCM non-intrusive
 monitoring function. The value source(2) is not allowed
 if the corresponding instance of optIfODUkDirectionality
 has the value sink(1), and the value sink(1) is not allowed
 if the corresponding instance of optIfODUkDirectionality
 has the value source(2). Either the value sink(1) or
 source(2) is allowed if the corresponding instance of
 optIfODUkDirectionality has the value bidirectional(3).
 The value sink(1) means monitoring at the sink direction
 TCM signal of the ODUk CTP.
 The value source(2) means monitoring at the source direction
 path signal of the ODUk CTP."
 ::= { optIfODUkTNimConfigEntry 2 }
optIfODUkTNimDAPIExpected OBJECT-TYPE
 SYNTAX OptIfExDAPI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The DAPI expected by the receiver.
 This object has no effect if optIfODUkTNimTIMDetMode has
 the value off(1) or sapi(3)."
 ::= { optIfODUkTNimConfigEntry 3 }
optIfODUkTNimSAPIExpected OBJECT-TYPE
 SYNTAX OptIfExSAPI
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "The SAPI expected by the receiver.
 This object has no effect if optIfODUkTNimTIMDetMode has
 the value off(1) or dapi(2)."
 ::= { optIfODUkTNimConfigEntry 4 }
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE
 SYNTAX OptIfAcTI
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "The actual trace identifier accepted. The value of
 this object is unspecified if optIfODUkTNimCurrentStatus
 has any of the bit positions oci(0), lck(1), or ssf(5)
 set or if optIfODUkTNimRowStatus has any value other
 than active(1)."
 ::= { optIfODUkTNimConfigEntry 5 }
optIfODUkTNimTIMDetMode OBJECT-TYPE
 SYNTAX OptIfTIMDetMode
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the mode of the Trace Identifier Mismatch (TIM)
 Detection function."
 ::= { optIfODUkTNimConfigEntry 6 }
optIfODUkTNimTIMActEnabled OBJECT-TYPE
 SYNTAX TruthValue
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates whether the Trace Identifier Mismatch (TIM)
 Consequent Action function is enabled."
 ::= { optIfODUkTNimConfigEntry 7 }
optIfODUkTNimDEGThr OBJECT-TYPE
 SYNTAX OptIfDEGThr
 UNITS "percentage"
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a performance
 monitoring (PM) Second to be bad. A PM Second is declared bad if
 the percentage of detected errored blocks in that second is
 greater than or equal to optIfODUkTNimDEGThr."
 ::= { optIfODUkTNimConfigEntry 8 }
optIfODUkTNimDEGM OBJECT-TYPE
 SYNTAX OptIfDEGM
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "Indicates the threshold level for declaring a Degraded Signal
 defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM
 consecutive bad PM Seconds are detected."
 ::= { optIfODUkTNimConfigEntry 9 }
optIfODUkTNimCurrentStatus OBJECT-TYPE
 SYNTAX BITS {
 oci(0),
 lck(1),
 tim(2),
 deg(3),
 bdi(4),
 ssf(5)
 }
 MAX-ACCESS read-only
 STATUS current
 DESCRIPTION
 "Indicates the defect condition of the entity, if any.
 The value of this object is unspecified if
 optIfODUkTNimRowStatus has any value other than
 active(1)."
 ::= { optIfODUkTNimConfigEntry 10 }
optIfODUkTNimRowStatus OBJECT-TYPE
 SYNTAX RowStatus
 MAX-ACCESS read-create
 STATUS current
 DESCRIPTION
 "This columnar object is used for creating and deleting a
 conceptual row of the optIfODUkTNim config table.
 It is used to model the addTCM and removeTCM operations of an
 ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection
 monitoring as defined in ITU-T G.874.1.
 Setting RowStatus to createAndGo or createAndWait implies addTCM.
 Setting RowStatus to destroy implies removeTCM.
 Successful addition/removal of Nim TCM will result in updating
 the optIfODUkPositionSeqCurrentSize variable and the
 optIfODUkPositionSeqTable table of the associated ODUk entry
 in the optIfODUkConfigTable."
 ::= { optIfODUkTNimConfigEntry 11 }
-- units of conformance
optIfOTMnGroup OBJECT-GROUP
 OBJECTS {
 optIfOTMnOrder,
 optIfOTMnReduced,
 optIfOTMnBitRates,
 optIfOTMnInterfaceType,
 optIfOTMnTcmMax,
 optIfOTMnOpticalReach
 }
 STATUS current
 DESCRIPTION
 "A collection of OTMn structure information objects."
 ::= { optIfGroups 1 }
optIfPerfMonGroup OBJECT-GROUP
 OBJECTS {
 optIfPerfMonCurrentTimeElapsed,
 optIfPerfMonCurDayTimeElapsed,
 optIfPerfMonIntervalNumIntervals,
 optIfPerfMonIntervalNumInvalidIntervals
 }
 STATUS current
 DESCRIPTION
 "A collection of performance monitoring interval objects."
 ::= { optIfGroups 2 }
optIfOTSnCommonGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnDirectionality
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OTSn interfaces."
 ::= { optIfGroups 3 }
optIfOTSnSourceGroupFull OBJECT-GROUP
 OBJECTS {
 optIfOTSnTraceIdentifierTransmitted
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to full-functionality/IaDI OTSn
 interfaces that support source functions."
 ::= { optIfGroups 4 }
optIfOTSnAPRStatusGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnAprStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of objects applicable to
 OTSn interfaces that support Automatic
 Power Reduction functions."
 ::= { optIfGroups 5 }
optIfOTSnAPRControlGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnAprControl
 }
 STATUS current
 DESCRIPTION
 "A collection of objects applicable to
 OTSn interfaces that provide Automatic
 Power Reduction control functions."
 ::= { optIfGroups 6 }
optIfOTSnSinkGroupBasic OBJECT-GROUP
 OBJECTS {
 optIfOTSnCurrentStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OTSn interfaces that
 support sink functions."
 ::= { optIfGroups 7 }
optIfOTSnSinkGroupFull OBJECT-GROUP
 OBJECTS {
 optIfOTSnDAPIExpected,
 optIfOTSnSAPIExpected,
 optIfOTSnTraceIdentifierAccepted,
 optIfOTSnTIMDetMode,
 optIfOTSnTIMActEnabled
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to full-functionality/IaDI OTSn
 interfaces that support sink functions."
 ::= { optIfGroups 8 }
optIfOTSnSinkPreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnSinkCurrentSuspectedFlag,
 optIfOTSnSinkCurrentInputPower,
 optIfOTSnSinkCurrentLowInputPower,
 optIfOTSnSinkCurrentHighInputPower,
 optIfOTSnSinkCurrentOutputPower,
 optIfOTSnSinkCurrentLowOutputPower,
 optIfOTSnSinkCurrentHighOutputPower,
 optIfOTSnSinkIntervalSuspectedFlag,
 optIfOTSnSinkIntervalLastInputPower,
 optIfOTSnSinkIntervalLowInputPower,
 optIfOTSnSinkIntervalHighInputPower,
 optIfOTSnSinkIntervalLastOutputPower,
 optIfOTSnSinkIntervalLowOutputPower,
 optIfOTSnSinkIntervalHighOutputPower,
 optIfOTSnSinkCurDaySuspectedFlag,
 optIfOTSnSinkCurDayLowInputPower,
 optIfOTSnSinkCurDayHighInputPower,
 optIfOTSnSinkCurDayLowOutputPower,
 optIfOTSnSinkCurDayHighOutputPower,
 optIfOTSnSinkPrevDaySuspectedFlag,
 optIfOTSnSinkPrevDayLastInputPower,
 optIfOTSnSinkPrevDayLowInputPower,
 optIfOTSnSinkPrevDayHighInputPower,
 optIfOTSnSinkPrevDayLastOutputPower,
 optIfOTSnSinkPrevDayLowOutputPower,
 optIfOTSnSinkPrevDayHighOutputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OTSn interfaces that
 support sink functions."
 ::= { optIfGroups 9 }
optIfOTSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnSinkCurrentLowerInputPowerThreshold,
 optIfOTSnSinkCurrentUpperInputPowerThreshold,
 optIfOTSnSinkCurrentLowerOutputPowerThreshold,
 optIfOTSnSinkCurrentUpperOutputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OTSn interfaces
 that support sink functions."
 ::= { optIfGroups 10 }
optIfOTSnSourcePreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnSrcCurrentSuspectedFlag,
 optIfOTSnSrcCurrentOutputPower,
 optIfOTSnSrcCurrentLowOutputPower,
 optIfOTSnSrcCurrentHighOutputPower,
 optIfOTSnSrcCurrentInputPower,
 optIfOTSnSrcCurrentLowInputPower,
 optIfOTSnSrcCurrentHighInputPower,
 optIfOTSnSrcIntervalSuspectedFlag,
 optIfOTSnSrcIntervalLastOutputPower,
 optIfOTSnSrcIntervalLowOutputPower,
 optIfOTSnSrcIntervalHighOutputPower,
 optIfOTSnSrcIntervalLastInputPower,
 optIfOTSnSrcIntervalLowInputPower,
 optIfOTSnSrcIntervalHighInputPower,
 optIfOTSnSrcCurDaySuspectedFlag,
 optIfOTSnSrcCurDayLowOutputPower,
 optIfOTSnSrcCurDayHighOutputPower,
 optIfOTSnSrcCurDayLowInputPower,
 optIfOTSnSrcCurDayHighInputPower,
 optIfOTSnSrcPrevDaySuspectedFlag,
 optIfOTSnSrcPrevDayLastOutputPower,
 optIfOTSnSrcPrevDayLowOutputPower,
 optIfOTSnSrcPrevDayHighOutputPower,
 optIfOTSnSrcPrevDayLastInputPower,
 optIfOTSnSrcPrevDayLowInputPower,
 optIfOTSnSrcPrevDayHighInputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OTSn interfaces that
 support source functions."
 ::= { optIfGroups 11 }
optIfOTSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOTSnSrcCurrentLowerOutputPowerThreshold,
 optIfOTSnSrcCurrentUpperOutputPowerThreshold,
 optIfOTSnSrcCurrentLowerInputPowerThreshold,
 optIfOTSnSrcCurrentUpperInputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OTSn interfaces
 that support source functions."
 ::= { optIfGroups 12 }
optIfOMSnCommonGroup OBJECT-GROUP
 OBJECTS {
 optIfOMSnDirectionality
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OMSn interfaces."
 ::= { optIfGroups 13 }
optIfOMSnSinkGroupBasic OBJECT-GROUP
 OBJECTS {
 optIfOMSnCurrentStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OMSn interfaces that
 support sink functions."
 ::= { optIfGroups 14 }
optIfOMSnSinkPreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOMSnSinkCurrentSuspectedFlag,
 optIfOMSnSinkCurrentAggregatedInputPower,
 optIfOMSnSinkCurrentLowAggregatedInputPower,
 optIfOMSnSinkCurrentHighAggregatedInputPower,
 optIfOMSnSinkCurrentOutputPower,
 optIfOMSnSinkCurrentLowOutputPower,
 optIfOMSnSinkCurrentHighOutputPower,
 optIfOMSnSinkIntervalSuspectedFlag,
 optIfOMSnSinkIntervalLastAggregatedInputPower,
 optIfOMSnSinkIntervalLowAggregatedInputPower,
 optIfOMSnSinkIntervalHighAggregatedInputPower,
 optIfOMSnSinkIntervalLastOutputPower,
 optIfOMSnSinkIntervalLowOutputPower,
 optIfOMSnSinkIntervalHighOutputPower,
 optIfOMSnSinkCurDaySuspectedFlag,
 optIfOMSnSinkCurDayLowAggregatedInputPower,
 optIfOMSnSinkCurDayHighAggregatedInputPower,
 optIfOMSnSinkCurDayLowOutputPower,
 optIfOMSnSinkCurDayHighOutputPower,
 optIfOMSnSinkPrevDaySuspectedFlag,
 optIfOMSnSinkPrevDayLastAggregatedInputPower,
 optIfOMSnSinkPrevDayLowAggregatedInputPower,
 optIfOMSnSinkPrevDayHighAggregatedInputPower,
 optIfOMSnSinkPrevDayLastOutputPower,
 optIfOMSnSinkPrevDayLowOutputPower,
 optIfOMSnSinkPrevDayHighOutputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OMSn interfaces that
 support sink functions."
 ::= { optIfGroups 15 }
optIfOMSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOMSnSinkCurrentLowerInputPowerThreshold,
 optIfOMSnSinkCurrentUpperInputPowerThreshold,
 optIfOMSnSinkCurrentLowerOutputPowerThreshold,
 optIfOMSnSinkCurrentUpperOutputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OMSn interfaces
 that support sink functions."
 ::= { optIfGroups 16 }
optIfOMSnSourcePreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOMSnSrcCurrentSuspectedFlag,
 optIfOMSnSrcCurrentOutputPower,
 optIfOMSnSrcCurrentLowOutputPower,
 optIfOMSnSrcCurrentHighOutputPower,
 optIfOMSnSrcCurrentAggregatedInputPower,
 optIfOMSnSrcCurrentLowAggregatedInputPower,
 optIfOMSnSrcCurrentHighAggregatedInputPower,
 optIfOMSnSrcIntervalSuspectedFlag,
 optIfOMSnSrcIntervalLastOutputPower,
 optIfOMSnSrcIntervalLowOutputPower,
 optIfOMSnSrcIntervalHighOutputPower,
 optIfOMSnSrcIntervalLastAggregatedInputPower,
 optIfOMSnSrcIntervalLowAggregatedInputPower,
 optIfOMSnSrcIntervalHighAggregatedInputPower,
 optIfOMSnSrcCurDaySuspectedFlag,
 optIfOMSnSrcCurDayLowOutputPower,
 optIfOMSnSrcCurDayHighOutputPower,
 optIfOMSnSrcCurDayLowAggregatedInputPower,
 optIfOMSnSrcCurDayHighAggregatedInputPower,
 optIfOMSnSrcPrevDaySuspectedFlag,
 optIfOMSnSrcPrevDayLastOutputPower,
 optIfOMSnSrcPrevDayLowOutputPower,
 optIfOMSnSrcPrevDayHighOutputPower,
 optIfOMSnSrcPrevDayLastAggregatedInputPower,
 optIfOMSnSrcPrevDayLowAggregatedInputPower,
 optIfOMSnSrcPrevDayHighAggregatedInputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OMSn interfaces that
 support source functions."
 ::= { optIfGroups 17 }
optIfOMSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOMSnSrcCurrentLowerOutputPowerThreshold,
 optIfOMSnSrcCurrentUpperOutputPowerThreshold,
 optIfOMSnSrcCurrentLowerInputPowerThreshold,
 optIfOMSnSrcCurrentUpperInputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OMSn interfaces that
 that support source functions."
 ::= { optIfGroups 18 }
optIfOChGroupCommonGroup OBJECT-GROUP
 OBJECTS {
 optIfOChGroupDirectionality
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OChGroup interfaces."
 ::= { optIfGroups 19 }
optIfOChGroupSinkPreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOChGroupSinkCurrentSuspectedFlag,
 optIfOChGroupSinkCurrentAggregatedInputPower,
 optIfOChGroupSinkCurrentLowAggregatedInputPower,
 optIfOChGroupSinkCurrentHighAggregatedInputPower,
 optIfOChGroupSinkCurrentOutputPower,
 optIfOChGroupSinkCurrentLowOutputPower,
 optIfOChGroupSinkCurrentHighOutputPower,
 optIfOChGroupSinkIntervalSuspectedFlag,
 optIfOChGroupSinkIntervalLastAggregatedInputPower,
 optIfOChGroupSinkIntervalLowAggregatedInputPower,
 optIfOChGroupSinkIntervalHighAggregatedInputPower,
 optIfOChGroupSinkIntervalLastOutputPower,
 optIfOChGroupSinkIntervalLowOutputPower,
 optIfOChGroupSinkIntervalHighOutputPower,
 optIfOChGroupSinkCurDaySuspectedFlag,
 optIfOChGroupSinkCurDayLowAggregatedInputPower,
 optIfOChGroupSinkCurDayHighAggregatedInputPower,
 optIfOChGroupSinkCurDayLowOutputPower,
 optIfOChGroupSinkCurDayHighOutputPower,
 optIfOChGroupSinkPrevDaySuspectedFlag,
 optIfOChGroupSinkPrevDayLastAggregatedInputPower,
 optIfOChGroupSinkPrevDayLowAggregatedInputPower,
 optIfOChGroupSinkPrevDayHighAggregatedInputPower,
 optIfOChGroupSinkPrevDayLastOutputPower,
 optIfOChGroupSinkPrevDayLowOutputPower,
 optIfOChGroupSinkPrevDayHighOutputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OChGroup interfaces that
 support sink functions."
 ::= { optIfGroups 20 }
optIfOChGroupSinkPreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOChGroupSinkCurrentLowerInputPowerThreshold,
 optIfOChGroupSinkCurrentUpperInputPowerThreshold,
 optIfOChGroupSinkCurrentLowerOutputPowerThreshold,
 optIfOChGroupSinkCurrentUpperOutputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OChGroup interfaces
 that support sink functions."
 ::= { optIfGroups 21 }
optIfOChGroupSourcePreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOChGroupSrcCurrentSuspectedFlag,
 optIfOChGroupSrcCurrentOutputPower,
 optIfOChGroupSrcCurrentLowOutputPower,
 optIfOChGroupSrcCurrentHighOutputPower,
 optIfOChGroupSrcCurrentAggregatedInputPower,
 optIfOChGroupSrcCurrentLowAggregatedInputPower,
 optIfOChGroupSrcCurrentHighAggregatedInputPower,
 optIfOChGroupSrcIntervalSuspectedFlag,
 optIfOChGroupSrcIntervalLastOutputPower,
 optIfOChGroupSrcIntervalLowOutputPower,
 optIfOChGroupSrcIntervalHighOutputPower,
 optIfOChGroupSrcIntervalLastAggregatedInputPower,
 optIfOChGroupSrcIntervalLowAggregatedInputPower,
 optIfOChGroupSrcIntervalHighAggregatedInputPower,
 optIfOChGroupSrcCurDaySuspectedFlag,
 optIfOChGroupSrcCurDayLowOutputPower,
 optIfOChGroupSrcCurDayHighOutputPower,
 optIfOChGroupSrcCurDayLowAggregatedInputPower,
 optIfOChGroupSrcCurDayHighAggregatedInputPower,
 optIfOChGroupSrcPrevDaySuspectedFlag,
 optIfOChGroupSrcPrevDayLastOutputPower,
 optIfOChGroupSrcPrevDayLowOutputPower,
 optIfOChGroupSrcPrevDayHighOutputPower,
 optIfOChGroupSrcPrevDayLastAggregatedInputPower,
 optIfOChGroupSrcPrevDayLowAggregatedInputPower,
 optIfOChGroupSrcPrevDayHighAggregatedInputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OChGroup interfaces that
 support source functions."
 ::= { optIfGroups 22 }
optIfOChGroupSourcePreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOChGroupSrcCurrentLowerOutputPowerThreshold,
 optIfOChGroupSrcCurrentUpperOutputPowerThreshold,
 optIfOChGroupSrcCurrentLowerInputPowerThreshold,
 optIfOChGroupSrcCurrentUpperInputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OChGroup interfaces that
 that support source functions."
 ::= { optIfGroups 23 }
optIfOChCommonGroup OBJECT-GROUP
 OBJECTS {
 optIfOChDirectionality
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OCh interfaces."
 ::= { optIfGroups 24 }
optIfOChSinkGroupBasic OBJECT-GROUP
 OBJECTS {
 optIfOChCurrentStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OCh interfaces that
 support sink functions."
 ::= { optIfGroups 25 }
optIfOChSinkPreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOChSinkCurrentSuspectedFlag,
 optIfOChSinkCurrentInputPower,
 optIfOChSinkCurrentLowInputPower,
 optIfOChSinkCurrentHighInputPower,
 optIfOChSinkIntervalSuspectedFlag,
 optIfOChSinkIntervalLastInputPower,
 optIfOChSinkIntervalLowInputPower,
 optIfOChSinkIntervalHighInputPower,
 optIfOChSinkCurDaySuspectedFlag,
 optIfOChSinkCurDayLowInputPower,
 optIfOChSinkCurDayHighInputPower,
 optIfOChSinkPrevDaySuspectedFlag,
 optIfOChSinkPrevDayLastInputPower,
 optIfOChSinkPrevDayLowInputPower,
 optIfOChSinkPrevDayHighInputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OCh interfaces that
 support sink functions."
 ::= { optIfGroups 26 }
optIfOChSinkPreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOChSinkCurrentLowerInputPowerThreshold,
 optIfOChSinkCurrentUpperInputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OCh interfaces
 that support sink functions."
 ::= { optIfGroups 27 }
optIfOChSourcePreOtnPMGroup OBJECT-GROUP
 OBJECTS {
 optIfOChSrcCurrentSuspectedFlag,
 optIfOChSrcCurrentOutputPower,
 optIfOChSrcCurrentLowOutputPower,
 optIfOChSrcCurrentHighOutputPower,
 optIfOChSrcIntervalSuspectedFlag,
 optIfOChSrcIntervalLastOutputPower,
 optIfOChSrcIntervalLowOutputPower,
 optIfOChSrcIntervalHighOutputPower,
 optIfOChSrcCurDaySuspectedFlag,
 optIfOChSrcCurDayLowOutputPower,
 optIfOChSrcCurDayHighOutputPower,
 optIfOChSrcPrevDaySuspectedFlag,
 optIfOChSrcPrevDayLastOutputPower,
 optIfOChSrcPrevDayLowOutputPower,
 optIfOChSrcPrevDayHighOutputPower
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 objects applicable to OCh interfaces that
 support source functions."
 ::= { optIfGroups 28 }
optIfOChSourcePreOtnPMThresholdGroup OBJECT-GROUP
 OBJECTS {
 optIfOChSrcCurrentLowerOutputPowerThreshold,
 optIfOChSrcCurrentUpperOutputPowerThreshold
 }
 STATUS current
 DESCRIPTION
 "A collection of pre-OTN performance monitoring
 threshold objects applicable to OCh interfaces
 that support source functions."
 ::= { optIfGroups 29 }
optIfOTUkCommonGroup OBJECT-GROUP
 OBJECTS {
 optIfOTUkDirectionality,
 optIfOTUkBitRateK
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all OTUk interfaces."
 ::= { optIfGroups 30 }
optIfOTUkSourceGroup OBJECT-GROUP
 OBJECTS {
 optIfOTUkTraceIdentifierTransmitted,
 optIfOTUkSourceAdaptActive
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to OTUk interfaces that
 support source functions."
 ::= { optIfGroups 31 }
optIfOTUkSinkGroup OBJECT-GROUP
 OBJECTS {
 optIfOTUkDAPIExpected,
 optIfOTUkSAPIExpected,
 optIfOTUkTraceIdentifierAccepted,
 optIfOTUkTIMDetMode,
 optIfOTUkTIMActEnabled,
 optIfOTUkDEGThr,
 optIfOTUkDEGM,
 optIfOTUkSinkAdaptActive,
 optIfOTUkSinkFECEnabled,
 optIfOTUkCurrentStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to OTUk interfaces that
 support sink functions."
 ::= { optIfGroups 32 }
optIfGCC0Group OBJECT-GROUP
 OBJECTS {
 optIfGCC0Application,
 optIfGCC0RowStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of GCC0 configuration objects."
 ::= { optIfGroups 33 }
optIfODUkGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkDirectionality,
 optIfODUkBitRateK,
 optIfODUkTcmFieldsInUse,
 optIfODUkPositionSeqCurrentSize,
 optIfODUkPositionSeqPosition,
 optIfODUkPositionSeqPointer,
 optIfODUkTtpPresent
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all ODUk interfaces."
 ::= { optIfGroups 34 }
optIfODUkTtpSourceGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkTtpTraceIdentifierTransmitted
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all interfaces that support
 ODUk trail termination source functions."
 ::= { optIfGroups 35 }
optIfODUkTtpSinkGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkTtpDAPIExpected,
 optIfODUkTtpSAPIExpected,
 optIfODUkTtpTraceIdentifierAccepted,
 optIfODUkTtpTIMDetMode,
 optIfODUkTtpTIMActEnabled,
 optIfODUkTtpDEGThr,
 optIfODUkTtpDEGM,
 optIfODUkTtpCurrentStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of ODUk configuration objects
 applicable to all interfaces that support
 ODUk trail termination sink functions."
 ::= { optIfGroups 36 }
optIfODUkNimGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkNimDAPIExpected,
 optIfODUkNimSAPIExpected,
 optIfODUkNimTraceIdentifierAccepted,
 optIfODUkNimTIMDetMode,
 optIfODUkNimTIMActEnabled,
 optIfODUkNimDEGThr,
 optIfODUkNimDEGM,
 optIfODUkNimCurrentStatus,
 optIfODUkNimRowStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of ODUk Nim configuration objects."
 ::= { optIfGroups 37 }
optIfGCC12Group OBJECT-GROUP
 OBJECTS {
 optIfGCC12GCCPassThrough,
 optIfGCC12Application,
 optIfGCC12RowStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of GCC12 configuration objects."
 ::= { optIfGroups 38 }
optIfODUkTCommonGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkTRowStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all ODUkT instances."
 ::= { optIfGroups 39 }
optIfODUkTSourceGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkTTraceIdentifierTransmitted,
 optIfODUkTSourceLockSignalAdminState
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all ODUkT instances
 that provide source functions."
 ::= { optIfGroups 40 }
optIfODUkTSinkGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkTDAPIExpected,
 optIfODUkTSAPIExpected,
 optIfODUkTTraceIdentifierAccepted,
 optIfODUkTTIMDetMode,
 optIfODUkTTIMActEnabled,
 optIfODUkTDEGThr,
 optIfODUkTDEGM,
 optIfODUkTCurrentStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to all ODUkT instances
 that provide sink functions."
 ::= { optIfGroups 41 }
optIfODUkTSinkGroupCtp OBJECT-GROUP
 OBJECTS {
 optIfODUkTSinkMode,
 optIfODUkTSinkLockSignalAdminState
 }
 STATUS current
 DESCRIPTION
 "A collection of configuration objects
 applicable to ODUkT instances not
 colocated with an ODUk TTP that
 provide sink functions."
 ::= { optIfGroups 42 }
optIfODUkTNimGroup OBJECT-GROUP
 OBJECTS {
 optIfODUkTNimDAPIExpected,
 optIfODUkTNimSAPIExpected,
 optIfODUkTNimTraceIdentifierAccepted,
 optIfODUkTNimTIMDetMode,
 optIfODUkTNimTIMActEnabled,
 optIfODUkTNimDEGThr,
 optIfODUkTNimDEGM,
 optIfODUkTNimCurrentStatus,
 optIfODUkTNimRowStatus
 }
 STATUS current
 DESCRIPTION
 "A collection of ODUkT Nim configuration objects."
 ::= { optIfGroups 43 }
-- compliance specifications
optIfOtnConfigCompl MODULE-COMPLIANCE
 STATUS current
 DESCRIPTION
 "Implementation requirements for the OTN configuration
 functions defined in this MIB module."
 MODULE -- this module
 MANDATORY-GROUPS {
 optIfOTMnGroup,
 optIfOTSnCommonGroup
 }
 GROUP optIfOTSnSourceGroupFull
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) for which the corresponding
 instance of optIfOTSnDirectionality has the value
 source(2) or bidirectional(3), the corresponding
 instance of optIfOTMnReduced has the value false(2),
 and the corresponding instance of optIfOTMnInterfaceType
 specifies an OTMn interface type of 'IaDI'."
 GROUP optIfOTSnAPRStatusGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) that support Automatic Power
 Reduction functions."
 GROUP optIfOTSnAPRControlGroup
 DESCRIPTION
 "This group is optional, but is recommended for interfaces
 of ifType opticalTransport(196) that provide Automatic
 Power Reduction control functions."
 GROUP optIfOTSnSinkGroupBasic
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) for which the corresponding
 instance of optIfOTSnDirectionality has the value
 sink(1) or bidirectional(3)."
 GROUP optIfOTSnSinkGroupFull
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) for which the corresponding
 instance of optIfOTSnDirectionality has the value
 sink(1) or bidirectional(3), the corresponding
 instance of optIfOTMnReduced has the value false(2),
 and the corresponding instance of optIfOTMnInterfaceType
 specifies an OTMn interface type of 'IaDI'."
 GROUP optIfOMSnCommonGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) that support access to the OMS
 overhead information within the OTN Supervisory Channel."
 GROUP optIfOMSnSinkGroupBasic
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) that support access to the OMS Overhead
 information within the OSC (OTN Supervisory Channel)
 for which the corresponding
 instance of optIfOMSnDirectionality has the value
 sink(1) or bidirectional(3)."
 GROUP optIfOChGroupCommonGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannelGroup(219)."
 GROUP optIfOChCommonGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(195)."
 GROUP optIfOChSinkGroupBasic
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) for which the corresponding
 instance of optIfOChDirectionality has the value
 sink(1) or bidirectional(3)."
 GROUP optIfOTUkCommonGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support OTUk layer functions."
 GROUP optIfOTUkSourceGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support OTUk layer functions
 and for which the corresponding instance of
 optIfOTUkDirectionality has the value source(2) or
 bidirectional(3)."
 GROUP optIfOTUkSinkGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support OTUk layer functions
 and for which the corresponding instance of
 optIfOTUkDirectionality has the value sink(1) or
 bidirectional(3)."
 GROUP optIfGCC0Group
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support GCC0 access functions.
 It may be implemented only if the optIfOTUkCommonGroup
 is also implemented."
 GROUP optIfODUkGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support ODUk layer functions."
 GROUP optIfODUkTtpSourceGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) for which the corresponding
 instance of optIfODUkTtpPresent has the value
 true(1) and for which the corresponding instance of
 optIfODUkDirectionality has the value source(2) or
 bidirectional(3). It may be implemented only if the
 optIfODUkGroup is also implemented."
 GROUP optIfODUkTtpSinkGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) for which the corresponding
 instance of optIfODUkTtpPresent has the value
 true(1) and for which the corresponding instance of
 optIfODUkDirectionality has the value sink(1) or
 bidirectional(3). It may be implemented only if the
 optIfODUkGroup is also implemented."
 GROUP optIfODUkNimGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) for which the corresponding
 instance of optIfODUkTtpPresent has the value
 false(2). It may be implemented only if the
 optIfODUkGroup is also implemented."
 GROUP optIfGCC12Group
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support GCC12 access functions.
 It may be implemented only if the optIfODUkGroup
 is also implemented."
 GROUP optIfODUkTCommonGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support intrusive
 tandem connection monitoring. It may be implemented
 only if the optIfODUkGroup is also implemented."
 GROUP optIfODUkTSourceGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support intrusive
 tandem connection monitoring and for which
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value false(2), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value true(1).
 It may be implemented only if the optIfODUkGroup is
 also implemented."
 GROUP optIfODUkTSinkGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support intrusive
 tandem connection monitoring and for which
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It may be implemented only if the optIfODUkGroup is
 also implemented."
 GROUP optIfODUkTSinkGroupCtp
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support intrusive
 tandem connection monitoring and for which
 optIfODUkTtpPresent is false(2) and
 (i) optIfODUkDirectionality has the value bidirectional(3), or
 (ii) optIfODUkDirectionality has the value sink(1) and
 optIfODUkTCodirectional has the value true(1), or
 (iii) optIfODUkDirectionality has the value source(3) and
 optIfODUkTCodirectional has the value false(2).
 It may be implemented only if the optIfODUkGroup and
 optIfODUkTSinkGroup are also implemented."
 GROUP optIfODUkTNimGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support non-intrusive
 tandem connection monitoring. It may be implemented
 only if the optIfODUkGroup is also implemented."
 ::= { optIfCompl 1 }
optIfPreOtnPMCompl MODULE-COMPLIANCE
 STATUS current
 DESCRIPTION
 "Implementation requirements for Pre-OTN performance
 monitoring functions defined in this MIB module."
 MODULE -- this module
 MANDATORY-GROUPS {
 optIfPerfMonGroup
 }
 GROUP optIfOTSnSinkPreOtnPMGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) that support OTSn sink
 functions (i.e., for which the corresponding instance
 of optIfOTSnDirectionality -- if implemented -- has
 the value sink(1) or bidirectional(3))."
 GROUP optIfOTSnSinkPreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOTSnSinkPreOtnPMGroup is a prerequisite for
 implementing this group."
 GROUP optIfOTSnSourcePreOtnPMGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalTransport(196) that support OTSn source
 functions (i.e., for which the corresponding instance
 of optIfOTSnDirectionality -- if implemented -- has
 the value source(2) or bidirectional(3))."
 GROUP optIfOTSnSourcePreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOTSnSourcePreOtnPMGroup is a prerequisite for
 implementing this group "
 GROUP optIfOMSnSinkPreOtnPMGroup
 DESCRIPTION
 "This group is optional. It may be implemented by systems
 with the necessary instrumentation on interfaces of ifType
 opticalTransport(196) that support OMSn sink functions
 (i.e., for which the corresponding instance of
 optIfOMSnDirectionality -- if implemented -- has the value
 sink(1) or bidirectional(3))."
 GROUP optIfOMSnSinkPreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOMSnSinkPreOtnPMGroup is a prerequisite for
 implementing this group "
 GROUP optIfOMSnSourcePreOtnPMGroup
 DESCRIPTION
 "This group is optional. It may be implemented by systems
 with the necessary instrumentation on interfaces of ifType
 opticalTransport(196) that support OMSn source functions
 (i.e., for which the corresponding instance of
 optIfOMSnDirectionality -- if implemented -- has the value
 source(2) or bidirectional(3))."
 GROUP optIfOMSnSourcePreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOMSnSourcePreOtnPMGroup is a prerequisite for
 implementing this group "
 GROUP optIfOChGroupSinkPreOtnPMGroup
 DESCRIPTION
 "This group is optional. It may be implemented by systems
 with the necessary instrumentation on interfaces of ifType
 opticalChannelGroup(219) that support OChGroup sink functions
 (i.e., for which the corresponding instance of
 optIfOChGroupDirectionality -- if implemented -- has the value
 sink(1) or bidirectional(3))."
 GROUP optIfOChGroupSinkPreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOChGroupSinkPreOtnPMGroup is a prerequisite for
 implementing this group "
 GROUP optIfOChGroupSourcePreOtnPMGroup
 DESCRIPTION
 "This group is optional. It may be implemented by systems
 with the necessary instrumentation on interfaces of ifType
 opticalChannelGroup(219) that support OChGroup source functions
 (i.e., for which the corresponding instance of
 optIfOChGroupDirectionality -- if implemented -- has the value
 source(2) or bidirectional(3))."
 GROUP optIfOChGroupSourcePreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOChGroupSourcePreOtnPMGroup is a prerequisite for
 implementing this group "
 GROUP optIfOChSinkPreOtnPMGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support OCh sink functions
 (i.e., for which the corresponding instance of
 optIfOChDirectionality -- if implemented -- has the
 value sink(1) or bidirectional(3))."
 GROUP optIfOChSinkPreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOChSinkPreOtnPMGroup is a prerequisite for
 implementing this group "
 GROUP optIfOChSourcePreOtnPMGroup
 DESCRIPTION
 "This group is mandatory for interfaces of ifType
 opticalChannel(195) that support OCh source functions
 (i.e., for which the corresponding instance of
 optIfOChDirectionality -- if implemented -- has the
 value source(2) or bidirectional(3))."
 GROUP optIfOChSourcePreOtnPMThresholdGroup
 DESCRIPTION
 "This group is mandatory if and only if TCA notifications
 are implemented. If the objects of this group are instantiated
 then the implementation must also provide, in an
 enterprise MIB, suitable TCA notification definitions and
 notification control objects. Implementation of the
 optIfOChSourcePreOtnPMGroup is a prerequisite for
 implementing this group "
 ::= { optIfCompl 2 }
END
5. Security Considerations
 There are a number of management objects defined in this MIB module
 with a MAX-ACCESS clause of read-write and/or read-create. It is
 possible for writes to these objects to have disruptive effects on
 network operation that range from invalid performance data to traffic
 interruptions. Users of this MIB module must therefore be aware that
 support for SET operations in a non-secure environment without proper
 protection can have a negative effect on network operations. The
 most sensitive objects are the read-write and read-create objects
 listed in the optIfOtnConfigCompl compliance statement that control
 the maximum number of TCM levels allowed (optIfOTMnTcmMax), automatic
 power reduction (optIfOTSnAprControl), transmitted trail trace
 (optIfOTSnTraceIdentifierTransmitted,
 optIfOTUkTraceIdentifierTransmitted,
 optIfODUkTtpTraceIdentifierTransmitted,
 optIfODUkTTraceIdentifierTransmitted), expected source/destination
 access point identifiers (optIfOTSnDAPIExpected,
 optIfOTSnSAPIExpected, optIfOTUkDAPIExpected, optIfOTUkSAPIExpected,
 optIfODUkTtpDAPIExpected, optIfODUkTtpSAPIExpected,
 optIfODUkNimDAPIExpected, optIfODUkNimSAPIExpected,
 optIfODUkTDAPIExpected, optIfODUkTSAPIExpected,
 optIfODUkTNimDAPIExpected, optIfODUkTNimSAPIExpected), trace
 identifier mismatch detection mode (optIfOTSnTIMDetMode,
 optIfOTUkTIMDetMode, optIfODUkTtpTIMDetMode, optIfODUkNimTIMDetMode,
 optIfODUkTTIMDetMode, optIfODUkTNimTIMDetMode), trace identifier
 mismatch consequent action (optIfOTSnTIMActEnabled,
 optIfOTUkTIMActEnabled, optIfODUkTtpTIMActEnabled,
 optIfODUkNimTIMActEnabled, optIfODUkTTIMActEnabled,
 optIfODUkTNimTIMActEnabled), threshold level for declaring a PM
 Second to be bad (optIfOTUkDEGThr, optIfODUkTtpDEGThr,
 optIfODUkNimDEGThr, optIfODUkTDEGThr, optIfODUkTNimDEGThr), threshold
 level for declaring a Degraded Signal defect (optIfOTUkDEGM,
 optIfODUkTtpDEGM, optIfODUkNimDEGM, optIfODUkTDEGM,
 optIfODUkTNimDEGM), whether the sink/source adaptation function is
 activated (optIfOTUkSinkAdaptActive, optIfOTUkSourceAdaptActive),
 whether Forward Error Correction is supported
 (optIfOTUkSinkFECEnabled), the application transported by the GCC
 entities (optIfGCC0Application, optIfGCC12Application), creating and
 deleting a conceptual row of a config table (optIfGCC0RowStatus,
 optIfODUkNimRowStatus, optIfGCC12RowStatus, optIfODUkTRowStatus,
 optIfODUkTNimRowStatus), whether the selected GCC overhead bytes are
 passed through or modified (optIfGCC12GCCPassThrough), TCM mode
 (optIfODUkTSinkMode), and provisioning of the sink/source LOCK signal
 (optIfODUkTSinkLockSignalAdminState,
 optIfODUkTSourceLockSignalAdminState), as these may cause traffic
 interruptions if improperly set.
 The readable objects in this MIB module (i.e., the objects with a
 MAX-ACCESS other than not-accessible) may be considered sensitive in
 some environments since, collectively, they provide information about
 the performance of interfaces in OTN equipment or networks and can
 reveal aspects of their configuration. In such environments it is
 important to control even GET and NOTIFY access to these objects and
 possibly to encrypt the values of these objects when sending them
 over the network via SNMP.
 SNMP versions prior to SNMPv3 did not include adequate security.
 Even if the network itself is secure (for example by using IPSec),
 there is no control as to who on the secure network is allowed to
 access and GET/SET (read/change/create/delete) objects in this MIB
 module.
 It is RECOMMENDED that implementers consider the security features
 provided by the SNMPv3 framework (see [RFC3410], section 8),
 including full support for the SNMPv3 cryptographic mechanisms (for
 authentication and privacy).
 Further, deployment of SNMP versions prior to SNMPv3 is NOT
 RECOMMENDED. Instead, it is RECOMMENDED that SNMPv3 be deployed and
 cryptographic security be enabled. It is then a customer/operator
 responsibility to ensure that the SNMP entity giving access to an
 instance of this MIB module is properly configured to give access to
 the objects only to those principals (users) that have legitimate
 rights to indeed GET or SET (change/create/delete) them.
6. Acknowledgements
 Nathan Kohn initiated the concept, then gathered and coordinated the
 team that led to the initial version of the MIB. Mark Stewart/Brian
 Teer wrote sections on use of interface tables, reviewed the MIB
 Object Definitions for SNMP SMIv2 compliance, and wrote the PM
 sections in working with G.7710/Y.1701. Anni Huynh wrote the initial
 MIB definitions for the OTN interface. Tom Rutt wrote the summary
 section on the Structure of the MIB. Rishi Grover contributed to the
 objects to monitor banded amplifiers. Kam Lam wrote the sections on
 Optical Networking Terminology and the OTN layers configuration
 parameters. He was the editor for the last several versions of this
 document.
 Thanks to Maarten Vissers for providing insight into Optical
 Networking concepts. Thanks to Lakshmi Raman and Moshe Rozenblit for
 reviewing and commenting on a preliminary version of the document.
 Special thanks to C. Mike Heard for providing a top notch doctor
 review and many helpful suggestions to improve the MIB.
7. References
7.1. Normative References
 [RFC1213] McCloghrie, K. and M. Rose, "Management Information
 Base for Network Management of TCP/IP-based
 internets: MIB-II", STD 17, RFC 1213, March 1991.
 [RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
 J., Rose, M. and S. Waldbusser, "Structure of
 Management Information Version 2 (SMIv2)", STD 58,
 RFC 2578, April 1999.
 [RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
 J., Rose, M. and S. Waldbusser, "Textual Conventions
 for SMIv2", STD 58, RFC 2579, April 1999.
 [RFC2580] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
 J., Rose, M. and S. Waldbusser, "Conformance
 Statements for SMIv2", STD 58, RFC 2580, April 1999.
 [RFC2863] McCloghrie, K. and F. Kastenholz, "The Interfaces
 Group MIB", RFC 2863, June 2000.
 [RFC2864] McCloghrie, K. and G. Hanson, "The Inverted Stack
 Table Extension to the Interfaces Group MIB", RFC
 2864, June 2000.
 [RFC3411] Harrington, D., Presuhn, R. and B. Wijnen, "An
 Architecture for Describing Simple Network Management
 Protocol (SNMP) Management Frameworks", STD 62, RFC
 3411, December 2002.
 [RFC3418] Presuhn, R., "Management Information Base (MIB) for
 the Simple Network Management Protocol (SNMP)", STD
 62, RFC 3418, December 2002.
 [ITU-T G.709] ITU-T Recommendation G.709/Y.1331, "Network Node
 Interface for the Optical Transport Network (OTN)",
 (2/2001).
 [ITU-T G.798] ITU-T Recommendation G.798, "Characteristics of
 Optical Transport Network Hierarchy Equipment
 Functional Blocks", (1/2002).
 [ITU-T G.872] ITU-T Recommendation G.872, "Architecture of optical
 transport networks", (11/2001).
 [ITU-T G.874] ITU-T Recommendation G.874, "Management aspects of
 the optical transport network element", (12/2001).
 [ITU-T G.874.1] ITU-T Recommendation G.874.1, "OTN Protocol-neutral
 Management Information Model for the NE View",
 (1/2002).
 [ITU-T G.7710] ITU-T Recommendation G.7710/Y.1701, "Common Equipment
 Management Function Requirements", (12/2001)
 [ITU-T G.806] ITU-T Recommendation G.806, "Characteristics of
 Transport Equipment - Description methodology and
 generic functionality", (10/2000).
 [ITU-T G.957] ITU-T Recommendation G.957, "Optical interfaces for
 equipments and systems relating to the synchronous
 digital hierarchy", (7/1999).
 [ITU-T G.691] ITU-T Recommendation G.691, "Optical interfaces for
 single-channel STM-64, STM-256 and other SDH systems
 with optical amplifiers", (10/200).
7.2. Informative References
 [RFC3410] Case, J., Mundy, R., Partain, D. and B. Stewart,
 "Introduction and Applicability Statements for
 Internet-Standard Management Framework", RFC 3410,
 December 2002.
 [RFC3433] Bierman, A., Romascanu, D. and K. C. Norseth, "Entity
 Sensor Management Information Base", RFC 3433,
 December 2002.
8. Intellectual Property Statement
 The IETF takes no position regarding the validity or scope of any
 intellectual property or other rights that might be claimed to
 pertain to the implementation or use of the technology described in
 this document or the extent to which any license under such rights
 might or might not be available; neither does it represent that it
 has made any effort to identify any such rights. Information on the
 IETF's procedures with respect to rights in standards-track and
 standards-related documentation can be found in BCP-11. Copies of
 claims of rights made available for publication and any assurances of
 licenses to be made available, or the result of an attempt made to
 obtain a general license or permission for the use of such
 proprietary rights by implementers or users of this specification can
 be obtained from the IETF Secretariat.
 The IETF invites any interested party to bring to its attention any
 copyrights, patents or patent applications, or other proprietary
 rights which may cover technology that may be required to practice
 this standard. Please address the information to the IETF Executive
 Director.
9. Authors' Addresses
 Mark A. Stewart
 Senior Systems Analyst
 Raleigh, NC
 USA
 EMail: mstewart1@nc.rr.com
 An-ni Huynh
 Cetus Networks
 USA
 EMail: a_n_huynh@yahoo.com
 Hing-Kam Lam
 Lucent Technologies
 101 Crawfords Corner Road, Room 4C-616A
 Holmdel, NJ 07733
 USA
 Phone: +1 732-949-8338
 EMail: hklam@lucent.com
10. Full Copyright Statement
 Copyright (C) The Internet Society (2003). All Rights Reserved.
 This document and translations of it may be copied and furnished to
 others, and derivative works that comment on or otherwise explain it
 or assist in its implementation may be prepared, copied, published
 and distributed, in whole or in part, without restriction of any
 kind, provided that the above copyright notice and this paragraph are
 included on all such copies and derivative works. However, this
 document itself may not be modified in any way, such as by removing
 the copyright notice or references to the Internet Society or other
 Internet organizations, except as needed for the purpose of
 developing Internet standards in which case the procedures for
 copyrights defined in the Internet Standards process must be
 followed, or as required to translate it into languages other than
 English.
 The limited permissions granted above are perpetual and will not be
 revoked by the Internet Society or its successors or assignees.
 This document and the information contained herein is provided on an
 "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
 TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
 BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
 HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
 MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
 Funding for the RFC Editor function is currently provided by the
 Internet Society.

User Contributions:

Comment about this RFC, ask questions, or add new information about this topic:




AltStyle によって変換されたページ (->オリジナル) /