Site name
B11 building in Osaka Metropolitan University
AsiaFlux site code
OM1
Location Sakai, Osaka, Japan
Position 34°32'49.84"N, 135°30'10.30"E
Elevation 27 m above sea level
Slope 0 degree
Terrain type
Flat
Area -
Fetch 150 m
Climate Warm temperature (Cfa)
Mean annual air temperature
15.6 °C
Mean annual precipitation
1206.9 mm
Vegetation type
Roadside trees (Deciduous broad leaf trees)
Dominant Species (Overstory)
-
Dominant Species (Understory)
-
Canopy height
13.1 ± 2.9 m
Age -
LAI -
Soil type
Concrete and Asphalt
System Open-path eddy covariance
Wind speed
Sonic anemometer (Windmaster, Gill), until April, 2021
Sonic anemometer (CSAT3, Campbell Scientific Inc.), present
Air temperature
Sonic anemometer (Windmaster, Gill), until April, 2021
Sonic anemometer (CSAT3, Campbell Scientific Inc.), present
Water vapor
Open-path CO2/H2O analyzer (LI-7500, Li-Cor), until April,2021
Open-path CO2/H2O analyzer (EC150, Campbell Scientific
Inc.), present
CO2 Open-path CO2/H2O analyzer (LI-7500, Li-Cor), until April,2021
Open-path CO2/H2O analyzer (EC150, Campbell Scientific
Inc.), present
Measurement height
16.2 m
Sampling frequency
10 Hz
Averaging time
30 minutes
Data logger
CR1000X (Campbell Scientific Inc.)
Data storage
microSD card
Original data
Raw data
Observation items
Levels/Depth Instrument
Global solar radiation
(incoming)
0.9 m above roof
4 component net radiometer (MR-40, Eko, Japan)
Quantum sensor (ML-01, EKO)
Global solar radiation
(outgoing) 0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan)
Quantum sensor (ML-01, EKO)
Long-wave radiation
(incoming)
0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan)
Long-wave radiation
(outgoing)
0.9 m above roof 4 component net radiometer (MR-40, Eko, Japan)
Net radiation
0.9 m above roof Net Radiometer (NR LITE2, Kipp&Zonen)
PPFD (incoming)
- -
PPFD (outgoing)
- -
Direct/diffuse radiation
- -
Direct/diffuse PPFD
- -
Air temperature
0.8 m above roof
Platinum resistance thermometer and
capacitive (HMP60, Vaisala)
Humidity 0.8 m above roof Platinum resistance thermometer and
capacitive (HMP60, Vaisala)
Soil temperature
- -
Soil heat flux
0 cm above roof
0 cm above roof
Heat flux plate (TEC-3105, Kyohritsu,Japan)
Heat flux plate (HFP01-10, Hukseflux)
Soil water content
0~30 cm in
rooftop gardening
TDR sensor (CS616,Campbell Scientific Inc.)
Wind speed
1) 16.2 m a.g.l
2) 16.2 m a.g.l
3) 16 m a.g.l
1) Sonic anemometer (Windmaster, Gill), until April, 2021
2) Sonic anemometer (CSAT3, Campbell Scientific Inc.), present
3) Vane anemometer (5103, R.M. Young)
Wind direction
1) 16.2 m a.g.l
2) 16.2 m a.g.l
3) 16 m a.g.l 1) Sonic anemometer (Windmaster, Gill), until April, 2021
2) Sonic anemometer (CSAT3, Campbell Scientific Inc.), present
3) Vane anemometer (5103, R.M. Young)
Barometric pressure
16.2 m a.g.l
Barometer (PTB110, Vaisala)
Barometer (LI-7700, Li-Cor)
Precipitation 0 cm above roof
Tipping-bucket raingauge (WBO015, Nakase, Japan)
CO2 concentration
16.2 m a.g.l
Open-path CO2/H2O analyzer (LI-7500, Li-Cor), until April, 2021
Open-path CO2/H2O analyzer (EC150, Campbell Scientific Inc.), present
CO2 concentration
22.5 m a.g.l
Closed-path CO2/H2O analyzer (LI-850, Li-Cor)
Surface temperature
18.0 m a.g.l
Radiation thermometer (IT-405N, Horiba)
Roof temperature
0 cm above roof
Thermocouple
CH4 concentration
16.2 m a.g.l
Open-path CH4 analyzer (LI-7700, Li-Cor)
Ultraviolet radiation
0.9 m above roof
Quantum sensor (CAP-SU-200-SS,Apogee)
CO concentration
16.2 m a.g.l
Closed-path CO analyzer (Los Gatos Research)