CVE-2020-10265 Detail

Modified

This CVE record has been updated after NVD enrichment efforts were completed. Enrichment data supplied by the NVD may require amendment due to these changes.

Description

Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.


Metrics

NVD enrichment efforts reference publicly available information to associate vector strings. CVSS information contributed by other sources is also displayed.
CVSS 4.0 Severity and Vector Strings:

NIST CVSS score
NIST: NVD
N/A
NVD assessment not yet provided.
CVSS 3.x Severity and Vector Strings:

NIST CVSS score
NIST: NVD
Base Score: 9.4 CRITICAL
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H

Nist CVSS score does not match with CNA score
CNA: Alias Robotics S.L.
Base Score: 9.4 CRITICAL
Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H
CVSS 2.0 Severity and Vector Strings:

National Institute of Standards and Technology
NIST: NVD
Base Score: 9.0 HIGH
Vector: (AV:N/AC:L/Au:N/C:P/I:P/A:C)

Vendor Statements (disclaimer)

Official Statement from Universal Robots (04/12/2022)

Software version 5.10 brings improvements to usability and configurability of Secure Shell Protocol (SSH), such that tunneling can be used to secure primary, secondary, RT, RTDE, DashBoard server and other interfaces. Universal Robots recommends that all users use SSH tunneling to access these interfaces in applications requiring authentication and encryption. Additionally, SW version 5.10 includes a built-in configurable firewall, allowing fine-grained restrictions of remote access, and number of other security improvements. Universal Robots (UR) recommends always using the latest UR software, as security improvements will be rolled out continuously. CB2 and CB3 cobots are designed to be operating in factory networks where security relies on boundary protection (firewalls) and trusted clients on the network. They must only be connected to trusted networks and operated by authorized personnel.

References to Advisories, Solutions, and Tools

By selecting these links, you will be leaving NIST webspace. We have provided these links to other web sites because they may have information that would be of interest to you. No inferences should be drawn on account of other sites being referenced, or not, from this page. There may be other web sites that are more appropriate for your purpose. NIST does not necessarily endorse the views expressed, or concur with the facts presented on these sites. Further, NIST does not endorse any commercial products that may be mentioned on these sites. Please address comments about this page to [email protected].

URL Source(s) Tag(s)
https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/ Alias Robotics S.L., CVE Vendor Advisory

Weakness Enumeration

CWE-ID CWE Name Source
CWE-306 Missing Authentication for Critical Function cwe source acceptance level NIST Alias Robotics S.L.

Known Affected Software Configurations Switch to CPE 2.2

CPEs loading, please wait.

Denotes Vulnerable Software
Are we missing a CPE here? Please let us know.

Change History

4 change records found show changes

CVE Modified by CVE 11/20/2024 11:55:05 PM

Action Type Old Value New Value
Added Reference
https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/


CVE Modified by Alias Robotics S.L. 5/14/2024 2:14:46 AM

Action Type Old Value New Value

Vendor Comment by NIST 4/12/2022 1:44:33 PM

Action Type Old Value New Value
Added Vendor Comment
Software version 5.10 brings improvements to usability and configurability of Secure Shell Protocol (SSH), such that tunneling can be used to secure primary, secondary, RT, RTDE, DashBoard server and other interfaces. Universal Robots recommends that all users use SSH tunneling to access these interfaces in applications requiring authentication and encryption.
Additionally, SW version 5.10 includes a built-in configurable firewall, allowing fine-grained restrictions of remote access, and number of other security improvements. Universal Robots (UR) recommends always using the latest UR software, as security improvements will be rolled out continuously.
CB2 and CB3 cobots are designed to be operating in factory networks where security relies on boundary protection (firewalls) and trusted clients on the network. They must only be connected to trusted networks and operated by authorized personnel.


Initial Analysis by NIST 4/06/2020 7:14:19 PM

Action Type Old Value New Value
Added CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H


Added CVSS V2
NIST (AV:N/AC:L/Au:N/C:P/I:P/A:C)


Added CWE
NIST CWE-306


Added CPE Configuration
AND
 OR
 *cpe:2.3:a:universal-robots:ur_software:*:*:*:*:*:*:*:* versions from (including) 1.4
 OR
 cpe:2.3:h:universal-robots:ur10:-:*:*:*:*:*:*:*
 cpe:2.3:h:universal-robots:ur5:-:*:*:*:*:*:*:*


Added CPE Configuration
AND
 OR
 *cpe:2.3:a:universal-robots:ur_software:*:*:*:*:*:*:*:* versions from (including) 3.0.14989 up to (including) 3.3.3.292
 OR
 cpe:2.3:h:universal-robots:ur10:-:*:*:*:*:*:*:*
 cpe:2.3:h:universal-robots:ur3:-:*:*:*:*:*:*:*
 cpe:2.3:h:universal-robots:ur5:-:*:*:*:*:*:*:*


Added CPE Configuration
AND
 OR
 *cpe:2.3:a:universal-robots:ur_software:*:*:*:*:*:*:*:* versions from (including) 5.0
 OR
 cpe:2.3:h:universal-robots:ur10e:-:*:*:*:*:*:*:*
 cpe:2.3:h:universal-robots:ur3e:-:*:*:*:*:*:*:*
 cpe:2.3:h:universal-robots:ur5e:-:*:*:*:*:*:*:*


Changed Reference Type
https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/ No Types Assigned


https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/ Vendor Advisory


Quick Info

CVE Dictionary Entry:
CVE-2020-10265
NVD Published Date:
04/06/2020
NVD Last Modified:
11/20/2024
Source:
Alias Robotics S.L.

AltStyle によって変換されたページ (->オリジナル) /