voltage


Also found in: Dictionary, Thesaurus, Medical, Legal, Financial, Acronyms, Wikipedia.
Related to voltage: voltage drop

voltage

an electromotive force or potential difference expressed in volts
Collins Discovery Encyclopedia, 1st edition © HarperCollins Publishers 2005

voltage

[′vōl·tij]
(electricity)
Potential difference or electromotive force measured in volts.
McGraw-Hill Dictionary of Scientific & Technical Terms, 6E, Copyright © 2003 by The McGraw-Hill Companies, Inc.

voltage

Of an electric circuit, the greatest root-mean-square difference of potential between any two conductors of the circuit.
McGraw-Hill Dictionary of Architecture and Construction. Copyright © 2003 by McGraw-Hill Companies, Inc.

voltage

(electronics)
(Or "potential difference", "electro-motive force" (EMF)) A quantity measured as a signed difference between two points in an electrical circuit which, when divided by the resistance in Ohms between those points, gives the current flowing between those points in Amperes, according to Ohm's Law. Voltage is expressed as a signed number of Volts (V). The voltage gradient in Volts per metre is proportional to the force on a charge.

Voltages are often given relative to "earth" or "ground" which is taken to be at zero Volts. A circuit's earth may or may not be electrically connected to the actual earth.

The voltage between two points is also given by the charge present between those points in Coulombs divided by the capacitance in Farads. The capacitance in turn depends on the dielectric constant of the insulators present.

Yet another law gives the voltage across a piece of circuit as its inductance in Henries multiplied by the rate of change of current flow through it in Amperes per second.

A simple analogy likens voltage to the pressure of water in a pipe. Current is likened to the amount of water (charge) flowing per unit time.
This article is provided by FOLDOC - Free Online Dictionary of Computing (foldoc.org)
The following article is from The Great Soviet Encyclopedia (1979). It might be outdated or ideologically biased.

Voltage

The voltage (U) between two points in an electric circuit or electric field is equal to the work done by the electric field in transferring a positive unit charge from one point to the other. In a conservative electric field, the work does not depend on the displacement path of the charge; in this case the voltage between the two points coincides with the potential difference between the points.

In a nonconservative field, voltage depends on the displacement path of the charge between the two points. Nonconservative forces are active within any source of direct current (generators, storage batteries, galvanic cells, and the like). The voltage across the terminals of a current source is always assumed to be the work done by the electric field in transferring a positive unit charge along a path that lies outside the source. In this case the voltage is equal to the potential difference between the terminals of the source and is defined by Ohm’s law U = IR – ℰ, where I is the current, R is the internal resistance of the source, and ℰ is the electromotive force (emf) of the source. Under open-circuit conditions (I = 0) the absolute value of the voltage is equal to the emf of the source. Therefore the emf of the source is often defined as the open-circuit voltage across the terminals of the source.

For alternating currents, voltage is usually characterized by its effective value, which is the root-mean-square voltage value of one period. The voltage across the terminals of an AC source or an inductance coil is measured by the work done by the electric field in transferring a positive unit charge along a path outside the source or the coil. A rotational (nonconservative) electric field is particularly nonexistent along the path, and the voltage is equal to the potential difference.

Voltage is usually measured with a voltmeter. The unit of voltage in the International System of Units is the volt.

REFERENCES

Tamm, I. E. Osnovy leorii elektrichestvo, 9th ed. Moscow, 1976. Chapters 3 and 6.
Kalashnikov, S. G. Elektrichestvo, 4th ed. (Obshchii kurs fiziki.) Moscow, 1977. Chapter 3,7, and 21.

G. IA. MIAKISHEV

The Great Soviet Encyclopedia, 3rd Edition (1970-1979). © 2010 The Gale Group, Inc. All rights reserved.
References in periodicals archive ?
*By application, the global high voltage amplifier market is segmented into medical, industrial, nuclear, telecommunications, and others.
North America is likely to dominate global high voltage amplifier market over the forecast period due to the increasing demand for high voltage amplifiers in a number of industries, including medical, telecommunications, and aerospace and defense.
In normal operation condition, GSC control inputs consist of two loops, which is a reactive power control and DC link voltage system.
The reference current value ([I.sub.d]) of GSC controller is generated from DC link voltage during normal operation or from [P.sup.*.sub.LVRT] during the voltage dip.
It is why a rock falls, sound propagates, ocean waves travel, and why a voltage source will charge a capacitance.
Voltage Observations To illustrate the problem of interpreting voltage, consider a transmission line just after a switch connects a voltage source to the line.
This system consist of 13 buses which are interconnected by means of 10 lines (three and single phase lines), one generation unit, one main A-Y transformer to 115/4.16 kV, one in-line Y-Y transformer to 4.16/0.480 kV, one voltage regulator unit, two shunt capacitor banks, unbalanced spot and distributed loads [7].
As shown in Fig.3, the proposed CW voltage multiplier is constructed by a flipped cascade connection of the stages.
Diode [D.sub.1] conducts during positive half cycle storing input voltage in [C.sub.1].
Thus, the proposed AC voltage regulator demonstrated in Fig.

Encyclopedia browser ?
Full browser ?