4.5 FIT: Fit a curve
4.5.1 Syntax
FIT x1,y1 x2,y2 ... args
4.5.2 Purpose
Fits a set of data using piecewise polynomials, or splines.
4.5.3 Comments
This function fits a set of piecewise polynomials to a set of data.
For fixed sources, it defines voltage or current as a function of
time.
The meaning of the
x and
y values depends on the component type:
component
X
Y
C (capacitor)
voltage
charge
E (VCVS)
voltage
voltage
F (CCCS)
current
current
G (VCCS)
voltage
current
H (CCVS)
current
voltage
I (current source)
time
current
L (inductor)
current
flux
R (resistor)
current
voltage
V (voltage source)
time
voltage
Y (admittance)
voltage
current
VCCAP
voltage
capacitance
VCG
voltage
conductance
VCR
voltage
resistance
trans-capacitor
voltage
charge
The values of
x must be in increasing order.
If
order is 1, it is the same as
PWL. If
order is
3, it will use cubic splines. The result and its first two
derivatives are continuous.
Outside the specified range, it uses linear extrapolation. The
behavior depends on the parameters
below and
above. The
value of
below or
above is the derivative to use, which
is a resistance for resistors, voltage gain for a VCVS, and so on. If
it is not specified, the value is automatically determined.
The properties are determined by the value of
order.
Order = 3 (cubic splines)
The default is to use “natural” splines, which sets the second
derivative to zero at the boundary. If a value of
below or
above is specified, “clamped” splines will be used. In any
case, there will be a smooth transition at the boundaries. When using
“clamped” splines, the second derivative may have a discontinuity at
the boundaries
Order = 2 (quadratic splines)
By default, the derivative at the upper end is determined by the slope
of the last segment. This is also the derivative above the range.
Below the range, the derivative determined at the lower bound is used.
It is recommended that only one of
below and
above be
specified. If both are specified, the splines are determined using
above, and there will be a discontinuity in the derivative at
the lower bound.
Order = 1 (piecewise linear interploation)
For first order (linear) interpolation, the default slope outside the
range is the extension of the slope in the end segments. The
parameters
below and
above have no effect inside the
range.
Order = 0 (piecewise constant interploation)
The resulting value is constant over the interval, and has
discontinuities at the specified points. The parameters
below
and
above are ignored. The slope is always 0.
4.5.4 Parameters
- Order = x
- The order of the polynomial to fit,
within the supplied data. (Default = 3) Legal values are 0, 1, 2,
and 3, only.
- Below = x
- The value of the derivative to use
below or before the specified range.
- Above = x
- The value of the derivative to use
above or after the specified range.
4.5.5 Example
- C1 (2 0) fit (-5,-5u 0,0 1,1u 4,2u 5,2u) order=1
-
This “capacitor” stores 5 microcoulombs at -5 volts (negative,
corresponding to the negative voltage, as expected). The charge
varies linearly to 0 at 0 volts, acting like a 1 microfarad capacitor.
(C = dq/dv). This continues to 1 volt. The 0,0 point could have been
left out. The charge increases only to 2 microcoulombs at 4 volts,
for an incremental capacitance of 1u/3 or .3333 microfarads. The same
charge at 5 volts indicates that it saturates at 2 microcoulombs. For
negative voltages, the slope continues.