The probe for the p796 bus is built by connecting the cables from one HP1650B Pod to an 86-pin socket. The socket is plugged onto the multibus extension plug.
The Pod is wired as shown below:
Pod Multibus Pod +----------------+ NC 1 | | 2 NC NC 3 | | 4 NC NC 5 | | 6 NC NC 7 | | 8 NC NC 9 | | 10 NC NC 11 | | 12 NC P3-0 13 | BCLK/ INIT/ | 14 P3-1 P3-2 15 | BPRN/ BPRO/ | 16 P3-3 P3-4 17 | BUSY/ BREQ/ | 18 P3-5 P3-6 19 | MRDC/ MWTC/ | 20 P3-7 P3-8 21 | IORC/ IOWC/ | 22 P3-9 P3-10 23 | XACK/ INH1/ | 24 P3-11 P3-12 25 | AACK/ INH2/ | 26 P3-13 NC 27 | | 28 NC NC 29 | | 30 NC NC 31 | CCLK/ | 32 NC NC 33 | | 34 NC NC 35 | INT6/ INT7/ | 36 NC NC 37 | INT4/ INT5/ | 38 NC NC 39 | INT2/ INT3/ | 40 NC P3-15 41 | INT0/ INT1/ | 42 NC NC 43 | ARDE/ ADRF/ | 44 NC NC 45 | ARDC/ ADRD/ | 46 NC NC 47 | ARDA/ ADRB/ | 48 NC NC 49 | ARD8/ ADR9/ | 50 NC NC 51 | ARD6/ ADR7/ | 52 NC NC 53 | ARD4/ ADR5/ | 54 NC NC 55 | ARD2/ ADR3/ | 56 NC NC 57 | ARD0/ ADR1/ | 58 NC NC 59 | DATE/ DATF/ | 60 NC NC 61 | DATC/ DATD/ | 62 NC NC 63 | DATA/ DATB/ | 64 NC NC 65 | DAT8/ DAT9/ | 66 NC NC 67 | DAT6/ DAT7/ | 68 NC NC 69 | DAT4/ DAT5/ | 70 NC NC 71 | DAT2/ DAT3/ | 72 NC NC 73 | DAT0/ DAT1/ | 74 NC NC 75 | | 76 NC NC 77 | | 78 NC NC 79 | | 80 NC NC 81 | | 82 NC NC 83 | | 84 NC NC 85 | | 86 NC +----------------+
Bill
2225 MST 30 August 2012