FHIR Extensions Pack
1.0.0 - Working Copy
International flag
This page is part of the FHIR Core Extensions Registry (v1.0.0: Release 1.0) based on FHIR (HL7® FHIR® Standard) v5.0.0. The current version which supersedes this version is 5.2.0. For a full list of available versions, see the Directory of published versions
Copyright/Legal: This is an FHIR value set based on ASTM Standard, E1762-95 (2013) HL7 RoleClass OID 2.16.840.1.113883.5.110, HL7 Role Code 2.16.840.1.113883.5.111, HL7 ParticipationType OID: 2.16.840.1.113883.5.90, HL7 ParticipationFunction codes at OID: 2.16.840.1.113883.5.88, and HL7 Security and Privacy Domain Analysis Model roles classes. These codes are excerpted from Digital Imaging and Communications in Medicine (DICOM) Standard, Part 16: Content Mapping Resource, Copyright © 2011 by the National Electrical Manufacturers Association.
This FHIR value set is comprised of lifecycle event codes. The FHIR Actor value set is based on DICOM Audit Message, ParticipantObjectDataLifeCycle; ISO Standard, TS 21089-2017;
References
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle
This value set contains 42 concepts
Expansion based on:
Occurs when an agent causes the system to obtain and open a record entry for inspection or review.
Occurs when an agent causes the system to tag or otherwise indicate special access management and suspension of record entry deletion/destruction, if deemed relevant to a lawsuit or which are reasonably anticipated to be relevant or to fulfill organizational policy under the legal doctrine of "duty to preserve".
Occurs when an agent makes any change to record entry content currently residing in storage considered permanent (persistent).
Occurs when an agent causes the system to create and move archive artifacts containing record entry content, typically to long-term offline storage.
Occurs when an agent causes the system to capture the agent’s digital signature (or equivalent indication) during formal validation of record entry content.
Occurs when an agent causes the system to decode record entry content from a cipher.
Occurs when an agent causes the system to scrub record entry content to reduce the association between a set of identifying data and the data subject in a way that might or might not be reversible.
Occurs when an agent causes the system to tag record entry(ies) as obsolete, erroneous or untrustworthy, to warn against its future use.
Occurs when an agent causes the system to permanently erase record entry content from the system.
Occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content.
Occurs when an agent causes the system to encode record entry content in a cipher.
Occurs when an agent causes the system to selectively pull out a subset of record entry content, based on explicit criteria.
Occurs when an agent causes the system to connect related record entries.
Occurs when an agent causes the system to combine or join content from two or more record entries, resulting in a single logical record entry.
Occurs when an agent causes the system to: a) initiate capture of potential record content, and b) incorporate that content into the storage considered a permanent part of the health record.
Occurs when an agent causes the system to remove record entry content to reduce the association between a set of identifying data and the data subject in a way that may be reversible.
Occurs when an agent causes the system to recreate or restore full status to record entries previously deleted or deprecated.
Occurs when an agent causes the system to a) initiate capture of data content from elsewhere, and b) incorporate that content into the storage considered a permanent part of the health record.
Occurs when an agent causes the system to restore information to data that allows identification of information source and/or information subject.
Occurs when an agent causes the system to remove a tag or other cues for special access management had required to fulfill organizational policy under the legal doctrine of "duty to preserve".
Occurs when an agent causes the system to produce and deliver record entry content in a particular form and manner.
Occurs when an agent causes the system to recreate record entries and their content from a previous created archive artefact.
Occurs when an agent causes the system to change the form, language or code system used to represent record entry content.
Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another.
Occurs when an agent causes the system to disconnect two or more record entries previously connected, rendering them separate (disconnected) again.
Occurs when an agent causes the system to reverse a previous record entry merge operation, rendering them separate again.
Occurs when an agent causes the system to confirm compliance of data or data objects with regulations, requirements, specifications, or other imposed conditions based on organizational policy.