This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4
Detailed Descriptions for the elements in the extension.
A specific offset time in milliseconds from the stated time in the Observation.appliesDateTime to allow for representation of sequential recording of sampled data from the same lead or data stream. For example, an ECG recorder may record sequentially 3 leads four time to receive 12-lead ECG, see ISO 22077.
Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
An Extension
Source of the definition for the extension code - a logical name or a URL.
The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension.
Value of extension - must be one of a constrained set of the data types (see Extensibility for a list).